These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 28727787)

  • 1. Feasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy.
    Yea JW; Park JW; Kim SK; Kim DY; Kim JG; Seo CY; Jeong WH; Jeong MY; Oh SA
    PLoS One; 2017; 12(7):e0181560. PubMed ID: 28727787
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy.
    Kadoya N; Abe K; Nemoto H; Sato K; Ieko Y; Ito K; Dobashi S; Takeda K; Jingu K
    Radiol Phys Technol; 2019 Sep; 12(3):351-356. PubMed ID: 31364005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance.
    Kamomae T; Shimizu H; Nakaya T; Okudaira K; Aoyama T; Oguchi H; Komori M; Kawamura M; Ohtakara K; Monzen H; Itoh Y; Naganawa S
    Phys Med; 2017 Dec; 44():205-211. PubMed ID: 29102154
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3D printed heterogeneous paediatric head and adult thorax phantoms for linear accelerator radiotherapy quality assurance: from fabrication to treatment delivery.
    Bustillo JPO; Posadas JRD; Mata JL; Inocencio ET; Rosenfeld AB; Lerch MLF
    Biomed Phys Eng Express; 2024 Aug; 10(5):. PubMed ID: 39142300
    [No Abstract]   [Full Text] [Related]  

  • 5. Patient specific 3D printed phantom for IMRT quality assurance.
    Ehler ED; Barney BM; Higgins PD; Dusenbery KE
    Phys Med Biol; 2014 Oct; 59(19):5763-73. PubMed ID: 25207965
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity modulated radiation therapy].
    Kadoya N; Abe K; Nemoto H; Sato K; Ieko Y; Ito K; Dobashi S; Takeda K; Jingu K
    Igaku Butsuri; 2020; 40(3):109. PubMed ID: 32999249
    [No Abstract]   [Full Text] [Related]  

  • 7. A method for generating intensity-modulated radiation therapy fields for small animal irradiators utilizing 3D-printed compensator molds.
    Yoon SW; Kodra J; Miles DA; Kirsch DG; Oldham M
    Med Phys; 2020 Sep; 47(9):4363-4371. PubMed ID: 32281657
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Patient-specific quality assurance for the delivery of (60)Co intensity modulated radiation therapy subject to a 0.35-T lateral magnetic field.
    Li HH; Rodriguez VL; Green OL; Hu Y; Kashani R; Wooten HO; Yang D; Mutic S
    Int J Radiat Oncol Biol Phys; 2015 Jan; 91(1):65-72. PubMed ID: 25442343
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A customizable anthropomorphic phantom for dosimetric verification of 3D-printed lung, tissue, and bone density materials.
    Tino RB; Yeo AU; Brandt M; Leary M; Kron T
    Med Phys; 2022 Jan; 49(1):52-69. PubMed ID: 34796527
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications.
    Makris DN; Pappas EP; Zoros E; Papanikolaou N; Saenz DL; Kalaitzakis G; Zourari K; Efstathopoulos E; Maris TG; Pappas E
    Phys Med Biol; 2019 May; 64(10):105009. PubMed ID: 30965289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT.
    Korevaar EW; Wauben DJ; van der Hulst PC; Langendijk JA; Van't Veld AA
    Radiother Oncol; 2011 Sep; 100(3):446-52. PubMed ID: 21963288
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA.
    Zhen H; Nelms BE; Tome WA
    Med Phys; 2011 Oct; 38(10):5477-89. PubMed ID: 21992366
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiochromic film based transit dosimetry for verification of dose delivery with intensity modulated radiotherapy.
    Chung K; Yoon M; Son J; Yong Park S; Lee K; Shin D; Kyung Lim Y; Byeong Lee S
    Med Phys; 2013 Feb; 40(2):021725. PubMed ID: 23387748
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design, construction, and dosimetry of 3D printed heterogeneous phantoms for synchrotron brain cancer radiation therapy quality assurance.
    Bustillo JPO; Paino J; Barnes M; Cayley J; de Rover V; Cameron M; Engels EEM; Tehei M; Beirne S; Wallace GG; Rosenfeld AB; Lerch MLF
    Phys Med Biol; 2024 Jul; 69(14):. PubMed ID: 38914107
    [No Abstract]   [Full Text] [Related]  

  • 15. Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy.
    Kim MJ; Lee SR; Lee MY; Sohn JW; Yun HG; Choi JY; Jeon SW; Suh TS
    PLoS One; 2017; 12(5):e0176227. PubMed ID: 28472175
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance.
    Graves YJ; Smith AA; Mcilvena D; Manilay Z; Lai YK; Rice R; Mell L; Jia X; Jiang SB; Cerviño L
    Med Phys; 2015 Apr; 42(4):1490-7. PubMed ID: 25832039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An anthropomorphic 3D printed inhomogeneity thorax phantom slab for SBRT commissioning and quality assurance.
    How S; Banjade D; Crowe S; Dillon G; Skimmings A
    Phys Eng Sci Med; 2023 Jun; 46(2):575-583. PubMed ID: 36806158
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterizing 3D printing in the fabrication of variable density phantoms for quality assurance of radiotherapy.
    Madamesila J; McGeachy P; Villarreal Barajas JE; Khan R
    Phys Med; 2016 Jan; 32(1):242-7. PubMed ID: 26508016
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MRIgRT head and neck anthropomorphic QA phantom: Design, development, reproducibility, and feasibility study.
    Steinmann A; Alvarez P; Lee H; Court L; Stafford R; Sawakuchi G; Wen Z; Fuller CD; Followill D
    Med Phys; 2020 Feb; 47(2):604-613. PubMed ID: 31808949
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a four-axis moving phantom for patient-specific QA of surrogate signal-based tracking IMRT.
    Mukumoto N; Nakamura M; Yamada M; Takahashi K; Akimoto M; Miyabe Y; Yokota K; Kaneko S; Nakamura A; Itasaka S; Matsuo Y; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2016 Dec; 43(12):6364. PubMed ID: 27908156
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.