173 related articles for article (PubMed ID: 28741892)
1. Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis.
Ade N; du Plessis FCP
J Appl Clin Med Phys; 2017 Sep; 18(5):162-173. PubMed ID: 28741892
[TBL] [Abstract][Full Text] [Related]
2. Measurement of the influence of titanium hip prosthesis on therapeutic electron beam dose distributions in a novel pelvic phantom.
Ade N; du Plessis FCP
Phys Med; 2017 Oct; 42():99-107. PubMed ID: 29173926
[TBL] [Abstract][Full Text] [Related]
3. Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system.
Paudel MR; Kim A; Sarfehnia A; Ahmad SB; Beachey DJ; Sahgal A; Keller BM
J Appl Clin Med Phys; 2016 Nov; 17(6):230-241. PubMed ID: 27929496
[TBL] [Abstract][Full Text] [Related]
4. Radiotherapy dose calculations in the presence of hip prostheses.
Keall PJ; Siebers JV; Jeraj R; Mohan R
Med Dosim; 2003; 28(2):107-12. PubMed ID: 12804709
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy.
Smith DW; Christophides D; Dean C; Naisbit M; Mason J; Morgan A
Med Phys; 2010 Jul; 37(7):3595-606. PubMed ID: 20831067
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of the accuracy of various dose calculation algorithms of a commercial treatment planning system in the presence of hip prosthesis and comparison with Monte Carlo.
Mohammadi K; Hassani M; Ghorbani M; Farhood B; Knaup C
J Cancer Res Ther; 2017; 13(3):501-509. PubMed ID: 28862217
[TBL] [Abstract][Full Text] [Related]
7. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
[TBL] [Abstract][Full Text] [Related]
8. Dose perturbation effect of metallic spinal implants in proton beam therapy.
Jia Y; Zhao L; Cheng CW; McDonald MW; Das IJ
J Appl Clin Med Phys; 2015 Sep; 16(5):333-343. PubMed ID: 26699317
[TBL] [Abstract][Full Text] [Related]
9. Dose attenuation effect of hip prostheses in a 9-MV photon beam: commercial treatment planning system versus Monte Carlo calculations.
Mesbahi A; Nejad FS
Radiat Med; 2007 Dec; 25(10):529-35. PubMed ID: 18085404
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo dose in a prosthesis phantom based on exact geometry vs streak artefact contaminated CT data as benchmarked against Gafchromic film measurements.
Ade N; Oderinde OM; du Plessis FCP
Phys Med; 2018 Oct; 54():94-102. PubMed ID: 30337015
[TBL] [Abstract][Full Text] [Related]
11. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
Chow JC; Grigorov GN
Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.
Ahmad SB; Sarfehnia A; Paudel MR; Kim A; Hissoiny S; Sahgal A; Keller B
Med Phys; 2016 Feb; 43(2):894-907. PubMed ID: 26843250
[TBL] [Abstract][Full Text] [Related]
13. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams.
Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D
Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153
[TBL] [Abstract][Full Text] [Related]
14. Planning of radiotherapy for patients with hip prosthesis.
Erlanson M; Franzén L; Henriksson R; Littbrand B; Löfroth PO
Int J Radiat Oncol Biol Phys; 1991 May; 20(5):1093-8. PubMed ID: 2022511
[TBL] [Abstract][Full Text] [Related]
15. A study on beams passing through hip prosthesis for pelvic radiation treatment.
Ding GX; Yu CW
Int J Radiat Oncol Biol Phys; 2001 Nov; 51(4):1167-75. PubMed ID: 11704342
[TBL] [Abstract][Full Text] [Related]
16. Monte carlo electron source model validation for an Elekta Precise linac.
Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
[TBL] [Abstract][Full Text] [Related]
17. Traditional and MLC based dose compensator design for patients with hip prostheses undergoing pelvic radiation therapy.
Alecu R; Alecu M; Loomis T; Ochran T; He T
Med Dosim; 1999; 24(1):33-7. PubMed ID: 10100163
[TBL] [Abstract][Full Text] [Related]
18. Evaluating impact of medium variation on dose calculated through planning system in a low cost in-house phantom.
Saini A; Pandey VP; Singh A; Kumar P
Biomed Phys Eng Express; 2022 Feb; 8(2):. PubMed ID: 35144251
[No Abstract] [Full Text] [Related]
19. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
McCaw TJ; Micka JA; DeWerd LA
Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
[TBL] [Abstract][Full Text] [Related]
20. Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations.
Martens C; Reynaert N; De Wagter C; Nilsson P; Coghe M; Palmans H; Thierens H; De Neve W
Med Phys; 2002 Jul; 29(7):1528-35. PubMed ID: 12148735
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]