These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 28745648)

  • 1. Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry.
    Yang HC; Chang CH; Urban PL
    J Vis Exp; 2017 Jul; (125):. PubMed ID: 28745648
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fizzy Extraction of Volatile and Semivolatile Compounds into the Gas Phase.
    Chang CH; Urban PL
    Anal Chem; 2016 Sep; 88(17):8735-40. PubMed ID: 27504910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On-line coupling of fizzy extraction with gas chromatography.
    Yang HC; Urban PL
    Anal Bioanal Chem; 2019 May; 411(12):2511-2520. PubMed ID: 30911801
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct analysis of volatile organic compounds in foods by headspace extraction atmospheric pressure chemical ionisation mass spectrometry.
    Perez-Hurtado P; Palmer E; Owen T; Aldcroft C; Allen MH; Jones J; Creaser CS; Lindley MR; Turner MA; Reynolds JC
    Rapid Commun Mass Spectrom; 2017 Nov; 31(22):1947-1956. PubMed ID: 28857369
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gas purge microsyringe extraction for quantitative direct gas chromatographic-mass spectrometric analysis of volatile and semivolatile chemicals.
    Yang C; Piao X; Qiu J; Wang X; Ren C; Li D
    J Chromatogr A; 2011 Mar; 1218(12):1549-55. PubMed ID: 21333296
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid detection of drugs in biofluids using atmospheric pressure chemi/chemical ionization mass spectrometry.
    Chen LC; Hashimoto Y; Furuya H; Takekawa K; Kubota T; Hiraoka K
    Rapid Commun Mass Spectrom; 2009 Feb; 23(3):333-9. PubMed ID: 19125420
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors.
    Constanzer ML; Chavez-Eng CM; Dru J; Kline WF; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug; 807(2):243-50. PubMed ID: 15203036
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Advances in offline approaches for trace measurements of complex organic compound mixtures via soft ionization and high-resolution tandem mass spectrometry.
    Khare P; Marcotte A; Sheu R; Walsh AN; Ditto JC; Gentner DR
    J Chromatogr A; 2019 Aug; 1598():163-174. PubMed ID: 30928166
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Importance of gas-phase proton affinities in determining the electrospray ionization response for analytes and solvents.
    Amad MH; Cech NB; Jackson GS; Enke CG
    J Mass Spectrom; 2000 Jul; 35(7):784-9. PubMed ID: 10934432
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasonic nebulization extraction coupled with headspace single-drop microextraction of volatile and semivolatile compounds from the seed of Cuminum cyminum L.
    Zhang H; Shi Y; Wei S; Wang Y; Zhang H
    Talanta; 2011 Aug; 85(2):1081-7. PubMed ID: 21726742
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dispersive micro-solid-phase extraction using mesoporous hybrid materials for simultaneous determination of semivolatile compounds from plant tea by ultra-high-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry.
    Cao W; Hu SS; Ye LH; Cao J
    J Agric Food Chem; 2014 Oct; 62(40):9683-9. PubMed ID: 25231266
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gas-phase separation of drugs and metabolites using modifier-assisted differential ion mobility spectrometry hyphenated to liquid extraction surface analysis and mass spectrometry.
    Porta T; Varesio E; Hopfgartner G
    Anal Chem; 2013 Dec; 85(24):11771-9. PubMed ID: 24251629
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dry ice fog extraction of volatile organic compounds.
    Yang HH; Urban PL
    J Chromatogr A; 2019 Jan; 1585():196-201. PubMed ID: 30502919
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gas chromatography coupled to tunable pulsed glow discharge time-of-flight mass spectrometry for environmental analysis.
    Solà-Vázquez A; Lara-Gonzalo A; Costa-Fernández JM; Pereiro R; Sanz-Medel A
    Analyst; 2010 May; 135(5):987-93. PubMed ID: 20419247
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid Extraction and Analysis of Volatile Solutes with an Effervescent Tablet.
    Elpa DP; Wu SP; Urban PL
    Anal Chem; 2020 Feb; 92(3):2756-2763. PubMed ID: 31902204
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automated Dual-Chamber Sampling System to Follow Dynamics of Volatile Organic Compounds Emitted by Biological Specimens.
    Chang CH; Urban PL
    Anal Chem; 2018 Dec; 90(23):13848-13854. PubMed ID: 30350607
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Catalytic Oxygenation-Mediated Extraction as a Facile and Green Way to Analyze Volatile Solutes.
    Raju CM; Yu KC; Shih CP; Elpa DP; Prabhu GRD; Urban PL
    Anal Chem; 2021 Jun; 93(25):8923-8930. PubMed ID: 34143609
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface.
    Gao L; Cooks RG; Ouyang Z
    Anal Chem; 2008 Jun; 80(11):4026-32. PubMed ID: 18461971
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Direct coupling of supercritical fluid extraction to a gas phase atmospheric pressure chemical ionisation source ion trap mass spectrometer for fast extraction and analysis of food components.
    Jublot L; Linforth RS; Taylor AJ
    J Chromatogr A; 2004 Nov; 1056(1-2):27-33. PubMed ID: 15595529
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct quantitative analysis of organic compounds in the gas and particle phase using a modified atmospheric pressure chemical ionization source in combination with ion trap mass spectrometry.
    Warscheid B; Kückelmann U; Hoffmann T
    Anal Chem; 2003 Mar; 75(6):1410-7. PubMed ID: 12659203
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.