These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
208 related articles for article (PubMed ID: 28751204)
1. Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing. Lee SH; Lee YH; Song HT; Suh JS Magn Reson Imaging; 2017 Oct; 42():152-157. PubMed ID: 28751204 [TBL] [Abstract][Full Text] [Related]
2. Fast isotropic volumetric magnetic resonance imaging of the ankle: Acceleration of the three-dimensional fast spin echo sequence using compressed sensing combined with parallel imaging. Yi J; Lee YH; Hahn S; Albakheet SS; Song HT; Suh JS Eur J Radiol; 2019 Mar; 112():52-58. PubMed ID: 30777219 [TBL] [Abstract][Full Text] [Related]
3. Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence. Lee SH; Lee YH; Suh JS Magn Reson Imaging; 2018 Feb; 46():90-97. PubMed ID: 29103976 [TBL] [Abstract][Full Text] [Related]
4. Knee imaging: Rapid three-dimensional fast spin-echo using compressed sensing. Kijowski R; Rosas H; Samsonov A; King K; Peters R; Liu F J Magn Reson Imaging; 2017 Jun; 45(6):1712-1722. PubMed ID: 27726244 [TBL] [Abstract][Full Text] [Related]
5. Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences. Altahawi FF; Blount KJ; Morley NP; Raithel E; Omar IM Skeletal Radiol; 2017 Jan; 46(1):7-15. PubMed ID: 27744578 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of an accelerated 3D modulated flip-angle technique in refocused imaging with an extended echo-train sequence with compressed sensing for imaging of the knee: comparison with routine 2D MRI sequences. Li G; Wu D; Xu Z; Zuo X; Li X; Chang S; Dai Y Clin Radiol; 2021 Feb; 76(2):158.e13-158.e18. PubMed ID: 33250173 [TBL] [Abstract][Full Text] [Related]
7. Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences. Park HJ; Lee SY; Park NH; Ahn JH; Chung EC; Kim SJ; Cha JG Acta Radiol; 2016 Nov; 57(11):1372-1379. PubMed ID: 25585852 [TBL] [Abstract][Full Text] [Related]
8. Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury. Park HJ; Lee SY; Park NH; Rho MH; Chung EC; Park JH; Park SJ Clin Radiol; 2016 Apr; 71(4):349-55. PubMed ID: 26774370 [TBL] [Abstract][Full Text] [Related]
9. Reconstruction of shoulder MRI using deep learning and compressed sensing: a validation study on healthy volunteers. Dratsch T; Siedek F; Zäske C; Sonnabend K; Rauen P; Terzis R; Hahnfeldt R; Maintz D; Persigehl T; Bratke G; Iuga A Eur Radiol Exp; 2023 Oct; 7(1):66. PubMed ID: 37880546 [TBL] [Abstract][Full Text] [Related]
10. Diagnosis of acetabular labral tears: comparison of three-dimensional intermediate-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography at 3.0 T. Park SY; Park JS; Jin W; Rhyu KH; Ryu KN Acta Radiol; 2013 Feb; 54(1):75-82. PubMed ID: 23093725 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR. Park HJ; Lee SY; Kim MS; Choi SH; Chung EC; Kook SH; Kim E Br J Radiol; 2015 Mar; 88(1047):20140147. PubMed ID: 25536442 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of an accelerated 3D SPACE sequence with compressed sensing and free-stop scan mode for imaging of the knee. Henninger B; Raithel E; Kranewitter C; Steurer M; Jaschke W; Kremser C Eur J Radiol; 2018 May; 102():74-82. PubMed ID: 29685548 [TBL] [Abstract][Full Text] [Related]
13. MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences. Foti G; Avanzi P; Mantovani W; Dal Corso F; Demozzi E; Zorzi C; Carbognin G Radiol Med; 2017 May; 122(5):353-360. PubMed ID: 28197872 [TBL] [Abstract][Full Text] [Related]
14. Liver T2-weighted MR imaging: assessment of a three-dimensional fast spin-echo with extended echo train acquisition sequence at 1.5 Tesla. Denoiseux CC; Boulay-Coletta I; Nakache JP; Claude ID; Zins M J Magn Reson Imaging; 2013 Aug; 38(2):336-43. PubMed ID: 23239080 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of the Articular Cartilage of the Knee Joint Using an Isotropic Resolution 3D Fast Spin-Echo Sequence With Conventional and Radial Reformatted Images. Gustas CN; Blankenbaker DG; Rio AM; Winalski CS; Kijowski R AJR Am J Roentgenol; 2015 Aug; 205(2):371-9. PubMed ID: 26204290 [TBL] [Abstract][Full Text] [Related]
16. 3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane. Park HJ; Lee SY; Choi YJ; Hong HP; Park SJ; Park JH; Kim E Clin Radiol; 2017 Feb; 72(2):176.e1-176.e7. PubMed ID: 27836104 [TBL] [Abstract][Full Text] [Related]