These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

268 related articles for article (PubMed ID: 28756064)

  • 21. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.
    Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E
    Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Accuracy of patient-specific instrumentation compared with conventional instrumentation in total knee arthroplasty.
    Jiang J; Kang X; Lin Q; Teng Y; An L; Ma J; Wang J; Xia Y
    Orthopedics; 2015 Apr; 38(4):e305-13. PubMed ID: 25901624
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.
    Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS
    Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Alignment and component position after patient-matched instrumentation versus conventional total knee arthroplasty.
    Pourgiezis N; Reddy SP; Nankivell M; Morrison G; VanEssen J
    J Orthop Surg (Hong Kong); 2016 Aug; 24(2):170-4. PubMed ID: 27574257
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer: a randomised controlled trial.
    Schotanus MG; Sollie R; van Haaren EH; Hendrickx RP; Jansen EJ; Kort NP
    Bone Joint J; 2016 Jun; 98-B(6):786-92. PubMed ID: 27235521
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Patient-specific instrumentation does not improve alignment in total knee arthroplasty.
    Russell R; Brown T; Huo M; Jones R
    J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty.
    Laende EK; Richardson CG; Dunbar MJ
    Bone Joint J; 2019 Aug; 101-B(8):929-940. PubMed ID: 31362561
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Component alignment and clinical outcome following total knee arthroplasty: a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation.
    Huijbregts HJ; Khan RJ; Fick DP; Hall MJ; Punwar SA; Sorensen E; Reid MJ; Vedove SD; Haebich S
    Bone Joint J; 2016 Aug; 98-B(8):1043-9. PubMed ID: 27482015
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Efficacy of Patient-Specific Instruments in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.
    Thienpont E; Schwab PE; Fennema P
    J Bone Joint Surg Am; 2017 Mar; 99(6):521-530. PubMed ID: 28291186
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Does final component alignment correlate with alignment of the bone resection surfaces in cemented total knee arthroplasty?
    Seo SS; Kim CW; Lee CR; Seo JH; Kim DH; Kim OG; Min YK
    Knee Surg Sports Traumatol Arthrosc; 2018 May; 26(5):1436-1444. PubMed ID: 27826637
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of custom to standard TKA instrumentation with computed tomography.
    Ng VY; Arnott L; Li J; Hopkins R; Lewis J; Sutphen S; Nicholson L; Reader D; McShane MA
    Knee Surg Sports Traumatol Arthrosc; 2014 Aug; 22(8):1833-42. PubMed ID: 23979518
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Component position alignment with patient-specific jigs in total knee arthroplasty.
    Moopanar TR; Amaranath JE; Sorial RM
    ANZ J Surg; 2014 Sep; 84(9):628-32. PubMed ID: 24946273
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.
    Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Postoperative alignment of TKA in patients with severe preoperative varus or valgus deformity: is there a difference between surgical techniques?
    Rahm S; Camenzind RS; Hingsammer A; Lenz C; Bauer DE; Farshad M; Fucentese SF
    BMC Musculoskelet Disord; 2017 Jun; 18(1):272. PubMed ID: 28637433
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Patient-specific instrumentation improved three-dimensional accuracy in total knee arthroplasty: a comparative radiographic analysis of 1257 total knee arthroplasties.
    Pauzenberger L; Munz M; Brandl G; Frank JK; Heuberer PR; Laky B; Schwameis E; Anderl W
    J Orthop Surg Res; 2019 Dec; 14(1):437. PubMed ID: 31831022
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Patient-specific instrumentation does not improve accuracy in total knee arthroplasty.
    Shen C; Tang ZH; Hu JZ; Zou GY; Xiao RC; Yan DX
    Orthopedics; 2015 Mar; 38(3):e178-88. PubMed ID: 25760504
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis.
    Tibesku CO; Haas SB; Saunders C; Harwood DA
    Arch Orthop Trauma Surg; 2023 Jul; 143(7):4379-4393. PubMed ID: 36449066
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty.
    Chen JY; Yeo SJ; Yew AK; Tay DK; Chia SL; Lo NN; Chin PL
    Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):630-5. PubMed ID: 23996069
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Image-Free Robotic-Assisted Total Knee Arthroplasty Improves Implant Alignment Accuracy: A Cadaveric Study.
    Doan GW; Courtis RP; Wyss JG; Green EW; Clary CW
    J Arthroplasty; 2022 Apr; 37(4):795-801. PubMed ID: 34979253
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation.
    Kerens B; Leenders AM; Schotanus MGM; Boonen B; Tuinebreijer WE; Emans PJ; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1823-1830. PubMed ID: 29282486
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.