These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

721 related articles for article (PubMed ID: 28756086)

  • 1. Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality.
    Tesche C; De Cecco CN; Schoepf UJ; Duguay TM; Albrecht MH; Caruso D; Varga-Szemes A; Lesslie VW; Ebersberger U; Canstein C; Thilo C; Hoffmann E; Allmendinger T; Nance JW
    J Cardiovasc Comput Tomogr; 2017; 11(5):354-359. PubMed ID: 28756086
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT coronary calcium scoring with tin filtration using iterative beam-hardening calcium correction reconstruction.
    Tesche C; De Cecco CN; Schoepf UJ; Duguay TM; Albrecht MH; De Santis D; Varga-Szemes A; Lesslie VW; Ebersberger U; Bayer RR; Canstein C; Hoffmann E; Allmendinger T; Nance JW
    Eur J Radiol; 2017 Jun; 91():29-34. PubMed ID: 28629567
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT.
    Choi AD; Leifer ES; Yu J; Shanbhag SM; Bronson K; Arai AE; Chen MY
    J Cardiovasc Comput Tomogr; 2016; 10(5):359-63. PubMed ID: 27591767
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction.
    Apfaltrer G; Albrecht MH; Schoepf UJ; Duguay TM; De Cecco CN; Nance JW; De Santis D; Apfaltrer P; Eid MH; Eason CD; Thompson ZM; Bauer MJ; Varga-Szemes A; Jacobs BE; Sorantin E; Tesche C
    Eur Radiol; 2018 Jul; 28(7):3097-3104. PubMed ID: 29404770
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study.
    McQuiston AD; Muscogiuri G; Schoepf UJ; Meinel FG; Canstein C; Varga-Szemes A; Cannao' PM; Wichmann JL; Allmendinger T; Vliegenthart R; De Cecco CN
    Eur J Radiol; 2016 Jan; 85(1):39-47. PubMed ID: 26724647
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.
    Hell MM; Bittner D; Schuhbaeck A; Muschiol G; Brand M; Lell M; Uder M; Achenbach S; Marwan M
    J Cardiovasc Comput Tomogr; 2014; 8(6):418-25. PubMed ID: 25439789
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration.
    Tesche C; De Cecco CN; Vliegenthart R; Albrecht MH; Varga-Szemes A; Duguay TM; Ebersberger U; Bayer RR; Canstein C; Schmidt B; Allmendinger T; Litwin SE; Morris PB; Flohr TG; Hoffmann E; Schoepf UJ
    Am J Cardiol; 2017 Feb; 119(4):675-680. PubMed ID: 27986261
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of iterative model reconstruction on coronary artery calcium quantification.
    Szilveszter B; Elzomor H; Károlyi M; Kolossváry M; Raaijmakers R; Benke K; Celeng C; Bartykowszki A; Bagyura Z; Lux Á; Merkely B; Maurovich-Horvat P
    Int J Cardiovasc Imaging; 2016 Jan; 32(1):153-60. PubMed ID: 26285899
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring.
    Willemink MJ; den Harder AM; Foppen W; Schilham AM; Rienks R; Laufer EM; Nieman K; de Jong PA; Budde RP; Nathoe HM; Leiner T
    J Cardiovasc Comput Tomogr; 2016; 10(1):69-75. PubMed ID: 26342405
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of Advanced Modeled Iterative Reconstruction on Coronary Artery Calcium Quantification.
    Messerli M; Rengier F; Desbiolles L; Ehl NF; Bauer RW; Leschka S; Alkadhi H; Wildermuth S; Nähle CP
    Acad Radiol; 2016 Dec; 23(12):1506-1512. PubMed ID: 27742177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Iterative image reconstruction techniques for CT coronary artery calcium quantification: comparison with traditional filtered back projection in vitro and in vivo.
    Schindler A; Vliegenthart R; Schoepf UJ; Blanke P; Ebersberger U; Cho YJ; Allmendinger T; Vogt S; Raupach R; Fink C; Saam T; Bamberg F; Nikolaou K; Apfaltrer P
    Radiology; 2014 Feb; 270(2):387-93. PubMed ID: 24471388
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting.
    André F; Fortner P; Vembar M; Mueller D; Stiller W; Buss SJ; Kauczor HU; Katus HA; Korosoglou G
    J Cardiovasc Comput Tomogr; 2017; 11(3):213-220. PubMed ID: 28314613
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adaptive Iterative Dose Reduction 3D Integrated with Automatic Tube Current Modulation for CT Coronary Artery Calcium Quantification: Comparison to Traditional Filtered Back Projection in an Anthropomorphic Phantom and Patients.
    Tang YC; Liu YC; Hsu MY; Tsai HY; Chen CM
    Acad Radiol; 2018 Aug; 25(8):1010-1017. PubMed ID: 29395796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm.
    Park CH; Lee J; Oh C; Han KH; Kim TH
    Int J Cardiovasc Imaging; 2015 Dec; 31 Suppl 2():197-203. PubMed ID: 26521066
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiography.
    Yuki H; Utsunomiya D; Funama Y; Tokuyasu S; Namimoto T; Hirai T; Itatani R; Katahira K; Oshima S; Yamashita Y
    J Cardiovasc Comput Tomogr; 2014; 8(2):115-23. PubMed ID: 24661824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm.
    Vingiani V; Abadia AF; Schoepf UJ; Fischer AM; Varga-Szemes A; Sahbaee P; Allmendinger T; Tesche C; Griffith LP; Marano R; Martin SS
    J Cardiovasc Comput Tomogr; 2020; 14(3):246-250. PubMed ID: 31843523
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of Hybrid Iterative Reconstruction on Agatston Coronary Artery Calcium Scores in Comparison to Filtered Back Projection in Native Cardiac CT.
    Obmann VC; Klink T; Heverhagen JT; Stork A; Laqmani A; Adam G; Begemann PG
    Rofo; 2015 May; 187(5):372-9. PubMed ID: 25962672
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
    Gordic S; Morsbach F; Schmidt B; Allmendinger T; Flohr T; Husarik D; Baumueller S; Raupach R; Stolzmann P; Leschka S; Frauenfelder T; Alkadhi H
    Invest Radiol; 2014 Jul; 49(7):465-73. PubMed ID: 24598443
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The impact of iterative reconstruction algorithms on machine learning-based coronary CT angiography-derived fractional flow reserve (CT-FFR
    Li S; Chen C; Qin L; Gu S; Zhang H; Yan F; Yang W
    Int J Cardiovasc Imaging; 2020 Jun; 36(6):1177-1185. PubMed ID: 32130576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correction Factors for CT Coronary Artery Calcium Scoring Using Advanced Modeled Iterative Reconstruction Instead of Filtered Back Projection.
    Caruso D; De Cecco CN; Schoepf UJ; Felmly LM; Varga-Szemes A; Mangold S; Canstein C; Allmendinger T; Fuller SR; Laghi A; Wichmann JL
    Acad Radiol; 2016 Dec; 23(12):1480-1489. PubMed ID: 27614365
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 37.