These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Direct imaging of the magnetization reversal in microwires using all-MOKE microscopy. Stupakiewicz A; Chizhik A; Tekielak M; Zhukov A; Gonzalez J; Maziewski A Rev Sci Instrum; 2014 Oct; 85(10):103702. PubMed ID: 25362398 [TBL] [Abstract][Full Text] [Related]
6. Magnetic Domain Patterns in Bilayered Ribbons Studied by Magnetic Force Microscopy and Magneto-Optical Kerr Microscopy. Trojková J; Životský O; Hendrych A; Markov D; Drobíková K Scanning; 2018; 2018():8308460. PubMed ID: 29780438 [TBL] [Abstract][Full Text] [Related]
7. Optimization of polarizer azimuth in improving signal-to-noise ratio in Kerr microscopy. Wang X; Lian J; Xu XJ; Li X; Li P; Li MM; Wang Y; Liu YX Appl Opt; 2016 Mar; 55(7):1725-30. PubMed ID: 26974636 [TBL] [Abstract][Full Text] [Related]
8. Submicrometer resolution far field high sensitivity Kerr microscopy for in-plane magnetization detection. Wang CH; Yang Z Rev Sci Instrum; 2009 Jul; 80(7):073107. PubMed ID: 19655943 [TBL] [Abstract][Full Text] [Related]
11. Direct detection of nonlinear ferromagnetic resonance in thin films by the magneto-optical Kerr effect. Gerrits T; Krivosik P; Schneider ML; Patton CE; Silva TJ Phys Rev Lett; 2007 May; 98(20):207602. PubMed ID: 17677740 [TBL] [Abstract][Full Text] [Related]
12. Quantitative study of the quadratic magneto-optical Kerr effects in Fe films. Liang JH; Xiao X; Li JX; Zhu BC; Zhu J; Bao H; Zhou L; Wu YZ Opt Express; 2015 May; 23(9):11357-66. PubMed ID: 25969230 [TBL] [Abstract][Full Text] [Related]
13. Optimization of magneto-optical Kerr setup: analyzing experimental assemblies using Jones matrix formalism. Polisetty S; Scheffler J; Sahoo S; Wang Y; Mukherjee T; He X; Binek Ch Rev Sci Instrum; 2008 May; 79(5):055107. PubMed ID: 18513092 [TBL] [Abstract][Full Text] [Related]
14. Resonant magneto-optic Kerr effects of a single Ni nanorod in the Mie scattering regime. Jeong HJ; Kim D; Song JH; Jeong KY; Seo MK Opt Express; 2016 Jul; 24(15):16904-12. PubMed ID: 27464142 [TBL] [Abstract][Full Text] [Related]
15. Magneto-optical linear dichroism in threshold photoemission electron microscopy of polycrystalline Fe films. Marx GK; Elmers HJ; Schönhense G Phys Rev Lett; 2000 Jun; 84(25):5888-91. PubMed ID: 10991080 [TBL] [Abstract][Full Text] [Related]
16. High resolution polar Kerr magnetometer for nanomagnetism and nanospintronics. Cormier M; Ferré J; Mougin A; Cromières JP; Klein V Rev Sci Instrum; 2008 Mar; 79(3):033706. PubMed ID: 18377014 [TBL] [Abstract][Full Text] [Related]
17. High resolution in situ magneto-optic Kerr effect and scanning tunneling microscopy setup with all optical components in UHV. Lehnert A; Buluschek P; Weiss N; Giesecke J; Treier M; Rusponi S; Brune H Rev Sci Instrum; 2009 Feb; 80(2):023902. PubMed ID: 19256657 [TBL] [Abstract][Full Text] [Related]
19. High contrast ballistic imaging using femtosecond optical Kerr gate of tellurite glass. Tan W; Zhou Z; Lin A; Si J; Zhan P; Wu B; Hou X Opt Express; 2013 Mar; 21(6):7740-7. PubMed ID: 23546155 [TBL] [Abstract][Full Text] [Related]
20. A high-resolution combined scanning laser and widefield polarizing microscope for imaging at temperatures from 4 K to 300 K. Lange M; Guénon S; Lever F; Kleiner R; Koelle D Rev Sci Instrum; 2017 Dec; 88(12):123705. PubMed ID: 29289195 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]