These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 28764518)

  • 1. Absolute calibration of imaging plate detectors for electron kinetic energies between 150 keV and 1.75 MeV.
    Singh S; Slavicek T; Hodak R; Versaci R; Pridal P; Kumar D
    Rev Sci Instrum; 2017 Jul; 88(7):075105. PubMed ID: 28764518
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Absolute calibration of image plates for electrons at energy between 100 keV and 4 MeV.
    Chen H; Back NL; Bartal T; Beg FN; Eder DC; Link AJ; MacPhee AG; Ping Y; Song PM; Throop A; Van Woerkom L
    Rev Sci Instrum; 2008 Mar; 79(3):033301. PubMed ID: 18377001
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration of imaging plate detectors to mono-energetic protons in the range 1-200 MeV.
    Rabhi N; Batani D; Boutoux G; Ducret JE; Jakubowska K; Lantuejoul-Thfoin I; Nauraye C; Patriarca A; Saïd A; Semsoum A; Serani L; Thomas B; Vauzour B
    Rev Sci Instrum; 2017 Nov; 88(11):113301. PubMed ID: 29195357
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors.
    Mancić A; Fuchs J; Antici P; Gaillard SA; Audebert P
    Rev Sci Instrum; 2008 Jul; 79(7):073301. PubMed ID: 18681694
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV.
    Bonnet T; Comet M; Denis-Petit D; Gobet F; Hannachi F; Tarisien M; Versteegen M; Aleonard MM
    Rev Sci Instrum; 2013 Jan; 84(1):013508. PubMed ID: 23387651
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Image-plate sensitivity to x rays at 2 to 60 keV.
    Rosenberg MJ; Thorn DB; Izumi N; Williams D; Rowland M; Torres G; Haugh M; Hillyard P; Adelman N; Schuler T; Barrios MA; Holder JP; Schneider MB; Fournier KB; Bradley DK; Regan SP
    Rev Sci Instrum; 2019 Jan; 90(1):013506. PubMed ID: 30709229
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Absolute response of Fuji imaging plate detectors to picosecond-electron bunches.
    Zeil K; Kraft SD; Jochmann A; Kroll F; Jahr W; Schramm U; Karsch L; Pawelke J; Hidding B; Pretzler G
    Rev Sci Instrum; 2010 Jan; 81(1):013307. PubMed ID: 20113093
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Study of imaging plate detector sensitivity to 5-18 MeV electrons.
    Boutoux G; Rabhi N; Batani D; Binet A; Ducret JE; Jakubowska K; Nègre JP; Reverdin C; Thfoin I
    Rev Sci Instrum; 2015 Nov; 86(11):113304. PubMed ID: 26628126
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Absolute calibration of Fujifilm BAS-TR image plate response to laser driven protons up to 40 MeV.
    Martin P; Ahmed H; Doria D; Alejo A; Clarke R; Ferguson S; Fernández-Tobias J; Freeman RR; Fuchs J; Green A; Green JS; Gwynne D; Hanton F; Jarrett J; Jung D; Kakolee KF; Krygier AG; Lewis CLS; McIlvenny A; McKenna P; Morrison JT; Najmudin Z; Naughton K; Nersisyan G; Norreys P; Notley M; Roth M; Ruiz JA; Scullion C; Zepf M; Zhai S; Borghesi M; Kar S
    Rev Sci Instrum; 2022 May; 93(5):053303. PubMed ID: 35649771
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the "PETawatt Aquitaine Laser".
    Boutoux G; Batani D; Burgy F; Ducret JE; Forestier-Colleoni P; Hulin S; Rabhi N; Duval A; Lecherbourg L; Reverdin C; Jakubowska K; Szabo CI; Bastiani-Ceccotti S; Consoli F; Curcio A; De Angelis R; Ingenito F; Baggio J; Raffestin D
    Rev Sci Instrum; 2016 Apr; 87(4):043108. PubMed ID: 27131655
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Energy-loss straggling algorithms for Monte Carlo electron transport.
    Chibani O
    Med Phys; 2002 Oct; 29(10):2374-83. PubMed ID: 12408312
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration of imaging plates to electrons between 40 and 180 MeV.
    Rabhi N; Bohacek K; Batani D; Boutoux G; Ducret JE; Guillaume E; Jakubowska K; Thaury C; Thfoin I
    Rev Sci Instrum; 2016 May; 87(5):053306. PubMed ID: 27250413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of electron dose-point kernels in water generated by the Monte Carlo codes, PENELOPE, GEANT4, MCNPX, and ETRAN.
    Uusijärvi H; Chouin N; Bernhardt P; Ferrer L; Bardiès M; Forssell-Aronsson E
    Cancer Biother Radiopharm; 2009 Aug; 24(4):461-7. PubMed ID: 19694581
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between an event-by-event Monte Carlo code, NOREC, and ETRAN for electron scaled point kernels between 20 keV and 1 MeV.
    Cho SH; Vassiliev ON; Horton JL
    Radiat Environ Biophys; 2007 Mar; 46(1):77-83. PubMed ID: 17219152
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image plate characterization and absolute calibration to low kilo-electron-volt electrons.
    Busold S; Philipp K; Otten A; Roth M
    Rev Sci Instrum; 2014 Nov; 85(11):113306. PubMed ID: 25430109
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calibration of BAS-TR image plate response to high energy (3-300 MeV) carbon ions.
    Doria D; Kar S; Ahmed H; Alejo A; Fernandez J; Cerchez M; Gray RJ; Hanton F; MacLellan DA; McKenna P; Najmudin Z; Neely D; Romagnani L; Ruiz JA; Sarri G; Scullion C; Streeter M; Swantusch M; Willi O; Zepf M; Borghesi M
    Rev Sci Instrum; 2015 Dec; 86(12):123302. PubMed ID: 26724017
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo simulation on a gold nanoparticle irradiated by electron beams.
    Chow JC; Leung MK; Jaffray DA
    Phys Med Biol; 2012 Jun; 57(11):3323-31. PubMed ID: 22572475
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
    Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
    Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography.
    Jaffray DA; Battista JJ; Fenster A; Munro P
    Med Phys; 1995 Jul; 22(7):1077-88. PubMed ID: 7565382
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Extracting W
    Tessier F; Cojocaru CD; Ross CK
    Med Phys; 2018 Jan; 45(1):370-381. PubMed ID: 29131343
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.