216 related articles for article (PubMed ID: 28768423)
1. Biomechanical comparison of conventional and optimised locking plates for the fixation of intraarticular calcaneal fractures: a finite element analysis.
Ouyang H; Deng Y; Xie P; Yang Y; Jiang B; Zeng C; Huang W
Comput Methods Biomech Biomed Engin; 2017 Sep; 20(12):1339-1349. PubMed ID: 28768423
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical comparison of conventional and anatomical calcaneal plates for the treatment of intraarticular calcaneal fractures - a finite element study.
Yu B; Chen WC; Lee PY; Lin KP; Lin KJ; Tsai CL; Wei HW
Comput Methods Biomech Biomed Engin; 2016 Oct; 19(13):1363-70. PubMed ID: 26813403
[TBL] [Abstract][Full Text] [Related]
3. Comparisons in finite element analysis of minimally invasive, locking, and non-locking plates systems used in treating calcaneal fractures of Sanders type II and type III.
He K; Fu S; Liu S; Wang Z; Jin D
Chin Med J (Engl); 2014; 127(22):3894-901. PubMed ID: 25421187
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures.
Ni M; Wong DW; Mei J; Niu W; Zhang M
Sci China Life Sci; 2016 Sep; 59(9):958-64. PubMed ID: 27349998
[TBL] [Abstract][Full Text] [Related]
5. Computational Biomechanical Analysis of Postoperative Calcaneal Fractures with Different Placement of the Sustentaculum Screw.
Qiang MF; Singh RK; Chen YX; Zhang K; Jia XY; Chen S; Wang SG; Wang X; Shi ZM
Orthop Surg; 2020 Apr; 12(2):661-667. PubMed ID: 32053281
[TBL] [Abstract][Full Text] [Related]
6. Finite element analyses of three minimally invasive fixation techniques for treating Sanders type II intra-articular calcaneal fractures.
Song G; Gu W; Shi Z; Li X; Fu S; Yu X; Song F
J Orthop Surg Res; 2023 Nov; 18(1):902. PubMed ID: 38012759
[TBL] [Abstract][Full Text] [Related]
7. Operative treatment of intraarticular calcaneal fractures: Anatomical and functional outcome of three different operative techniques.
Gusic N; Fedel I; Darabos N; Lovric Z; Bukvic N; Bakota B; Lemac D
Injury; 2015 Nov; 46 Suppl 6():S130-3. PubMed ID: 26606987
[TBL] [Abstract][Full Text] [Related]
8. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].
Zeman P; Zeman J; Matejka J; Koudela K
Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):457-64. PubMed ID: 19150004
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of modified Calcanail system with plating fixation in intra-articular calcaneal fracture: A finite element analysis.
Ni M; Wong DW; Niu W; Wang Y; Mei J; Zhang M
Med Eng Phys; 2019 Aug; 70():55-61. PubMed ID: 31229383
[TBL] [Abstract][Full Text] [Related]
10. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
[TBL] [Abstract][Full Text] [Related]
11. Design and Biomechanical Finite Element Analysis of Spatial Weaving Infracalcaneal Fixator System.
Zhang Y; Weng Q; Chen J; Yang Y
Orthop Surg; 2024 Apr; 16(4):976-983. PubMed ID: 38438142
[TBL] [Abstract][Full Text] [Related]
12. Comparison of nonlocking plates and locking plates for intraarticular calcaneal fracture.
Chen K; Zhang H; Wang G; Cheng Y; Qian Z; Yang H
Foot Ankle Int; 2014 Dec; 35(12):1298-302. PubMed ID: 25125513
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical evaluation of reconstruction plates with locking, nonlocking, and hybrid screws configurations in calcaneal fracture: a finite element model study.
Chen CH; Hung C; Hsu YC; Chen CS; Chiang CC
Med Biol Eng Comput; 2017 Oct; 55(10):1799-1807. PubMed ID: 28224272
[TBL] [Abstract][Full Text] [Related]
14. A comparison of conventional versus locking plates in intraarticular calcaneus fractures: a biomechanical study in human cadavers.
Stoffel K; Booth G; Rohrl SM; Kuster M
Clin Biomech (Bristol, Avon); 2007 Jan; 22(1):100-5. PubMed ID: 17007974
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical role of bone grafting for calcaneal fracture fixation in the presence of bone defect: A finite element analysis.
Su Z; Ding M; Zhu N; Cheung JC; Wong DW; Sun W; Ni M
Clin Biomech (Bristol, Avon); 2024 Jun; 116():106278. PubMed ID: 38821036
[TBL] [Abstract][Full Text] [Related]
16. Comminuted intraarticular calcaneal fractures: Multiplanar VA locked plating and interlocked nailing incorporate longitudinal strut and provide superior stability - a biomechanical cadaveric study.
Stefanov A; Ivanov S; Zderic I; Baltov A; Rashkov M; Gehweiler D; Richards G; Gueorguiev B; Enchev D
Injury; 2022 Oct; 53(10):3543-3552. PubMed ID: 35810043
[TBL] [Abstract][Full Text] [Related]
17. A biomechanical comparison of locking and nonlocking plates for the fixation of calcaneal fractures.
Redfern DJ; Oliveira ML; Campbell JT; Belkoff SM
Foot Ankle Int; 2006 Mar; 27(3):196-201. PubMed ID: 16539902
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical Performance of Lateral Versus Dual Locking Plates for Calcaneal Fractures.
Maxwell AB; Owen JR; Gilbert TM; Romash MM; Wayne JS; Adelaar RS
J Foot Ankle Surg; 2015; 54(5):830-5. PubMed ID: 25960057
[TBL] [Abstract][Full Text] [Related]
19. Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study.
Ma R; Shaikh AB; Zhang Q; Su X; Wang Y; Pan F; Chen J; He K
Med Sci Monit; 2023 Sep; 29():e940300. PubMed ID: 37674308
[TBL] [Abstract][Full Text] [Related]
20. Stability of locking and non-locking plates in an osteoporotic calcaneal fracture model.
Illert T; Rammelt S; Drewes T; Grass R; Zwipp H
Foot Ankle Int; 2011 Mar; 32(3):307-13. PubMed ID: 21477551
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]