These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 28768759)

  • 21. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.
    Kandzari DE; Mauri L; Koolen JJ; Massaro JM; Doros G; Garcia-Garcia HM; Bennett J; Roguin A; Gharib EG; Cutlip DE; Waksman R;
    Lancet; 2017 Oct; 390(10105):1843-1852. PubMed ID: 28851504
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Absorb bioresorbable vascular scaffold versus everolimus-eluting metallic stent in ST-segment elevation myocardial infarction: 1-year results of a propensity score matching comparison: the BVS-EXAMINATION Study (bioresorbable vascular scaffold-a clinical evaluation of everolimus eluting coronary stents in the treatment of patients with ST-segment elevation myocardial infarction).
    Brugaletta S; Gori T; Low AF; Tousek P; Pinar E; Gomez-Lara J; Scalone G; Schulz E; Chan MY; Kocka V; Hurtado J; Gomez-Hospital JA; Münzel T; Lee CH; Cequier A; Valdés M; Widimsky P; Serruys PW; Sabaté M
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt B):189-197. PubMed ID: 25616924
    [TBL] [Abstract][Full Text] [Related]  

  • 23. 2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy.
    Ali ZA; Serruys PW; Kimura T; Gao R; Ellis SG; Kereiakes DJ; Onuma Y; Simonton C; Zhang Z; Stone GW
    Lancet; 2017 Aug; 390(10096):760-772. PubMed ID: 28732815
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Mechanical properties of the everolimus-eluting bioresorbable vascular scaffold compared to the metallic everolimus-eluting stent.
    Dalos D; Gangl C; Roth C; Krenn L; Scherzer S; Vertesich M; Lang I; Maurer G; Neunteufl T; Berger R; Delle-Karth G
    BMC Cardiovasc Disord; 2016 May; 16():104. PubMed ID: 27225486
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Vascular response to everolimus- and biolimus-eluting coronary stents versus everolimus-eluting bioresorbable scaffolds--an optical coherence tomography substudy of the EVERBIO II trial.
    Kallinikou Z; Arroyo D; Togni M; Lehman S; Corpataux N; Cook M; Müller O; Baeriswyl G; Stauffer JC; Goy JJ; Puricel SG; Cook S
    Swiss Med Wkly; 2016; 146():w14274. PubMed ID: 26766027
    [TBL] [Abstract][Full Text] [Related]  

  • 26. 1-Year Outcomes of Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Stents: A Propensity-Matched Comparison of the GHOST-EU and XIENCE V USA Registries.
    Tamburino C; Capranzano P; Gori T; Latib A; Lesiak M; Nef H; Caramanno G; Naber C; Mehilli J; Di Mario C; Sabaté M; Münzel T; Colombo A; Araszkiewicz A; Wiebe J; Geraci S; Jensen C; Mattesini A; Brugaletta S; Capodanno D
    JACC Cardiovasc Interv; 2016 Mar; 9(5):440-9. PubMed ID: 26875648
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Everolimus-eluting ABSORB bioresorbable vascular scaffold: present and future perspectives.
    Brugaletta S; Garcia-Garcia HM; Onuma Y; Serruys PW
    Expert Rev Med Devices; 2012 Jul; 9(4):327-38. PubMed ID: 22420293
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes.
    Serruys PW; Onuma Y; Ormiston JA; de Bruyne B; Regar E; Dudek D; Thuesen L; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Dorange C; Veldhof S; Miquel-Hebert K; Rapoza R; García-García HM
    Circulation; 2010 Nov; 122(22):2301-12. PubMed ID: 21098436
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Bioresorbable vascular scaffolds for the treatment of coronary artery disease: what have we learned from randomized-controlled clinical trials?
    Rizik DG; Hermiller JB; Simonton CA; Klassen KJ; Kereiakes DJ
    Coron Artery Dis; 2017 Jan; 28(1):77-89. PubMed ID: 27561169
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease.
    Ellis SG; Kereiakes DJ; Metzger DC; Caputo RP; Rizik DG; Teirstein PS; Litt MR; Kini A; Kabour A; Marx SO; Popma JJ; McGreevy R; Zhang Z; Simonton C; Stone GW;
    N Engl J Med; 2015 Nov; 373(20):1905-15. PubMed ID: 26457558
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Incidence and short-term clinical outcomes of small side branch occlusion after implantation of an everolimus-eluting bioresorbable vascular scaffold: an interim report of 435 patients in the ABSORB-EXTEND single-arm trial in comparison with an everolimus-eluting metallic stent in the SPIRIT first and II trials.
    Muramatsu T; Onuma Y; García-García HM; Farooq V; Bourantas CV; Morel MA; Li X; Veldhof S; Bartorelli A; Whitbourn R; Abizaid A; Serruys PW;
    JACC Cardiovasc Interv; 2013 Mar; 6(3):247-57. PubMed ID: 23517836
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).
    Vlachojannis GJ; Smits PC; Hofma SH; Togni M; Vázquez N; Valdés M; Voudris V; Slagboom T; Goy JJ; den Heijer P; van der Ent M
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1215-1221. PubMed ID: 28579236
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical Outcomes After Implantation of Overlapping Bioresorbable Scaffolds vs New Generation Everolimus Eluting Stents.
    Panoulas VF; Kawamoto H; Sato K; Miyazaki T; Naganuma T; Sticchi A; Latib A; Colombo A
    Rev Esp Cardiol (Engl Ed); 2016 Dec; 69(12):1135-1143. PubMed ID: 27264490
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bioresorbable Scaffolds versus Metallic Stents in Routine PCI.
    Wykrzykowska JJ; Kraak RP; Hofma SH; van der Schaaf RJ; Arkenbout EK; IJsselmuiden AJ; Elias J; van Dongen IM; Tijssen RYG; Koch KT; Baan J; Vis MM; de Winter RJ; Piek JJ; Tijssen JGP; Henriques JPS;
    N Engl J Med; 2017 Jun; 376(24):2319-2328. PubMed ID: 28402237
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Will ABSORB III change my practice? Everolimus-eluting bioresorbable scaffolds for coronary artery disease.
    Cook S; Nef H; Capodanno D; Tamburino C; Baumbach A
    EuroIntervention; 2016 Aug; 12(6):801-4. PubMed ID: 27542795
    [No Abstract]   [Full Text] [Related]  

  • 36. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent.
    Ishibashi Y; Muramatsu T; Nakatani S; Sotomi Y; Suwannasom P; Grundeken MJ; Cho YK; Garcia-Garcia HM; van Boven AJ; Piek JJ; Sabaté M; Helqvist S; Baumbach A; McClean D; de Sousa Almeida M; Wasungu L; Miquel-Hebert K; Dudek D; Chevalier B; Onuma Y; Serruys PW
    JACC Cardiovasc Interv; 2015 Jul; 8(8):1053-1063. PubMed ID: 26205444
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Coronary artery aneurysms formation within Everolimus-eluting stents and bioresorbable vascular scaffolds.
    Lee WC; Chung WJ; Fang HY; Wu CJ
    Int J Cardiol; 2016 Mar; 206():58-60. PubMed ID: 26774833
    [No Abstract]   [Full Text] [Related]  

  • 38. From biodegradable polymers to bioresorbable vascular scaffolds: available evidence in the era of new-generation drug-eluting stents.
    Magliulo F; Piccolo R; Franzone A; Esposito G; Danzi GB
    Minerva Cardioangiol; 2018 Jun; 66(3):246-261. PubMed ID: 29160048
    [TBL] [Abstract][Full Text] [Related]  

  • 39. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design.
    Diletti R; Serruys PW; Farooq V; Sudhir K; Dorange C; Miquel-Hebert K; Veldhof S; Rapoza R; Onuma Y; Garcia-Garcia HM; Chevalier B
    Am Heart J; 2012 Nov; 164(5):654-63. PubMed ID: 23137495
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Reply to Letter to the Editor entitled: "Bioresorbable stent thrombosis, lactic acid release and Kounis syndrome".
    von Birgelen C; van der Heijden LC; Mukete BN
    Int J Cardiol; 2017 Nov; 247():16. PubMed ID: 28916056
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.