These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 28773014)

  • 1. Lamb Wave-Based Structural Health Monitoring on Composite Bolted Joints under Tensile Load.
    Yang B; Xuan FZ; Xiang Y; Li D; Zhu W; Tang X; Xu J; Yang K; Luo C
    Materials (Basel); 2017 Jun; 10(6):. PubMed ID: 28773014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nonlinear Guided-Wave Mixing for Condition Monitoring of Bolted Joints.
    Pineda Allen JC; Ng CT
    Sensors (Basel); 2021 Jul; 21(15):. PubMed ID: 34372328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Two-Dimensional Model for Pin-Load Distribution and Failure Analysis of Composite Bolted Joints.
    Li B; Gong Y; Xiao H; Gao Y; Liang E
    Materials (Basel); 2021 Jun; 14(13):. PubMed ID: 34208873
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Progressive Damage Numerical Modelling and Simulation of Aircraft Composite Bolted Joints Bearing Response.
    Gao G; An L; Giannopoulos IK; Han N; Ge E; Hu G
    Materials (Basel); 2020 Dec; 13(24):. PubMed ID: 33302590
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wave mode extraction from multimodal wave signals in an orthotropic composite plate.
    Ratassepp M; Fan Z; Lasn K
    Ultrasonics; 2016 Sep; 71():223-230. PubMed ID: 27403641
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transmission of Lamb waves across a partially closed crack: Numerical analysis and experiment.
    Matsushita M; Mori N; Biwa S
    Ultrasonics; 2019 Feb; 92():57-67. PubMed ID: 30245346
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Damage localization method for plates based on the time reversal of the mode-converted Lamb waves.
    Mori N; Biwa S; Kusaka T
    Ultrasonics; 2019 Jan; 91():19-29. PubMed ID: 30031966
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Debonding Detection in Aluminum/Rigid Polyurethane Foam Composite Plates Using A
    Yang X; Xu J; Zhang S; Tu J
    Materials (Basel); 2023 Mar; 16(7):. PubMed ID: 37049091
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On-Site Health Monitoring of Composite Bolted Joint Using Built-In Distributed Eddy Current Sensor Network.
    Liu Q; Sun H; Wang T; Qing X
    Materials (Basel); 2019 Aug; 12(17):. PubMed ID: 31470616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite.
    He M; Tao D; Li Z; Li M
    Materials (Basel); 2016 Jul; 9(7):. PubMed ID: 28773703
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Piezoelectric Transducers for Structural Health Monitoring of Joint Structures in Cylinders: A Wave-Based Design Approach.
    Wang W; Li L; Fan Y; Jiang Z
    Sensors (Basel); 2020 Jan; 20(3):. PubMed ID: 31973228
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanic-Electric-Thermal Directly Coupling Simulation Method of Lamb Wave under Temperature Effect.
    Yang X; Xue Z; Zheng H; Qiu L; Xiong K
    Sensors (Basel); 2022 Sep; 22(17):. PubMed ID: 36081104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Progressive fatigue damage analysis of composite bolted joint using equivalent stress model.
    Liu F; Xie M; Ji Y; Zhou M
    Sci Prog; 2020; 103(1):36850419874234. PubMed ID: 31829851
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Health Monitoring of Bolted Spherical Joint Connection Based on Active Sensing Technique Using Piezoceramic Transducers.
    Xu J; Wang C; Li H; Zhang C; Hao J; Fan S
    Sensors (Basel); 2018 May; 18(6):. PubMed ID: 29843369
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bidirectional, Bimodal Ultrasonic Lamb Wave Sensing in a Composite Plate Using a Polarization-Maintaining Fiber Bragg Grating.
    Rao C; Duan L
    Sensors (Basel); 2019 Mar; 19(6):. PubMed ID: 30893919
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design of optimal configuration for generating A0 Lamb mode in a composite plate using piezoceramic transducers.
    Grondel S; Paget C; Delebarre C; Assaad J; Levin K
    J Acoust Soc Am; 2002 Jul; 112(1):84-90. PubMed ID: 12141367
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Study of guided wave propagation on a plate between two solid bodies with imperfect contact conditions.
    Balvantín AJ; Diosdado-De-la-Peña JA; Limon-Leyva PA; Hernández-Rodríguez E
    Ultrasonics; 2018 Feb; 83():137-145. PubMed ID: 28615109
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The transmission of Lamb waves across adhesively bonded lap joints.
    Lowe MJ; Challis RE; Chan CW
    J Acoust Soc Am; 2000 Mar; 107(3):1333-45. PubMed ID: 10738787
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves.
    Tiwari KA; Raisutis R; Mazeika L; Samaitis V
    Sensors (Basel); 2018 Mar; 18(4):. PubMed ID: 29587472
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the Directivity of Lamb Waves Generated by Wedge PZT Actuator in Thin CFRP Panel.
    Shevtsov S; Chebanenko V; Shevtsova M; Chang SH; Kirillova E; Rozhkov E
    Materials (Basel); 2020 Feb; 13(4):. PubMed ID: 32085550
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.