These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 28773893)

  • 1. Electrochemical Corrosion Behavior of Ta₂N Nanoceramic Coating in Simulated Body Fluid.
    Cheng J; Xu J; Liu LL; Jiang S
    Materials (Basel); 2016 Sep; 9(9):. PubMed ID: 28773893
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrochemical Properties of a Novel β-Ta
    Xu J; Hu W; Xu S; Munroe P; Xie ZH
    ACS Biomater Sci Eng; 2016 Jan; 2(1):73-89. PubMed ID: 33418645
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrochemical Corrosion Behavior of Nanocrystalline β-Ta Coating for Biomedical Applications.
    Liu LL; Xu J; Lu X; Munroe P; Xie ZH
    ACS Biomater Sci Eng; 2016 Apr; 2(4):579-594. PubMed ID: 33465860
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of semiconducting properties of passive films on the cavitation erosion resistance of a NbN nanoceramic coating.
    Xu J; Peng S; Li Z; Jiang S; Xie ZH; Munroe P
    Ultrason Sonochem; 2021 Mar; 71():105406. PubMed ID: 33310652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrochemical and mechanical behavior of laser processed Ti-6Al-4V surface in Ringer's physiological solution.
    Singh R; Tiwari SK; Mishra SK; Dahotre NB
    J Mater Sci Mater Med; 2011 Aug; 22(8):1787-96. PubMed ID: 21660586
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrochemical investigation of chromium oxide-coated Ti-6Al-4V and Co-Cr-Mo alloy substrates.
    Swaminathan V; Zeng H; Lawrynowicz D; Zhang Z; Gilbert JL
    J Biomed Mater Res B Appl Biomater; 2011 Aug; 98(2):369-78. PubMed ID: 21648063
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In-situ monitoring of the electrochemical behavior of cellular structured biomedical Ti-6Al-4V alloy fabricated by electron beam melting in simulated physiological fluid.
    Gai X; Bai Y; Li S; Hou W; Hao Y; Zhang X; Yang R; Misra RDK
    Acta Biomater; 2020 Apr; 106():387-395. PubMed ID: 32058079
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tantalum Nitride-Decorated Titanium with Enhanced Resistance to Microbiologically Induced Corrosion and Mechanical Property for Dental Application.
    Zhang Y; Zheng Y; Li Y; Wang L; Bai Y; Zhao Q; Xiong X; Cheng Y; Tang Z; Deng Y; Wei S
    PLoS One; 2015; 10(6):e0130774. PubMed ID: 26107177
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrochemical Behaviour of Ti and Ti-6Al-4V Alloy in Phosphate Buffered Saline Solution.
    Gudić S; Vrsalović L; Kvrgić D; Nagode A
    Materials (Basel); 2021 Dec; 14(24):. PubMed ID: 34947090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Laser surface modification of Ti--6Al--4V: wear and corrosion characterization in simulated biofluid.
    Singh R; Kurella A; Dahotre NB
    J Biomater Appl; 2006 Jul; 21(1):49-73. PubMed ID: 16443617
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion resistance evaluation of a Ca- and P-based bioceramic thin coating in Ti-6Al-4V.
    Coelho PG; de Assis SL; Costa I; Thompson VP
    J Mater Sci Mater Med; 2009 Jan; 20(1):215-22. PubMed ID: 18726187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrochemical behavior of (Ti 1-x Nb x)5Si3 nanocrystalline films in simulated physiological media.
    Liu L; Xu J; Munroe P; Xu J; Xie ZH
    Acta Biomater; 2014 Feb; 10(2):1005-13. PubMed ID: 24076074
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of Tricalcium Magnesium Silicate Coating on the Electrochemical and Biological Behavior of Ti-6Al-4V Alloys.
    Maleki-Ghaleh H; Hafezi M; Hadipour M; Nadernezhad A; Aghaie E; Behnamian Y; Abu Osman NA
    PLoS One; 2015; 10(9):e0138454. PubMed ID: 26383641
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ti-O-N/Ti composite coating on Ti-6Al-4V: surface characteristics, corrosion properties and cellular responses.
    Cao XL; Sun T; Yu Y
    J Mater Sci Mater Med; 2015 Mar; 26(3):144. PubMed ID: 25737126
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti-6Al-4V alloy with a smooth surface or treated with double-acid-etching.
    Faverani LP; Assunção WG; de Carvalho PS; Yuan JC; Sukotjo C; Mathew MT; Barao VA
    PLoS One; 2014; 9(3):e93377. PubMed ID: 24671257
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of Ru on structure and corrosion behavior of passive film on Ti-6Al-4V alloy in oil and gas exploration conditions.
    Liu Q; Liu H; Xie J; Zhang WF; Zhang YM; Feng C; Li GS; Yu Y; Song SY; Yin CX
    Sci Rep; 2022 Oct; 12(1):16586. PubMed ID: 36198740
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nanomechanical properties, wear resistance and in-vitro characterization of Ta
    Sarraf M; Razak BA; Nasiri-Tabrizi B; Dabbagh A; Kasim NHA; Basirun WJ; Bin Sulaiman E
    J Mech Behav Biomed Mater; 2017 Feb; 66():159-171. PubMed ID: 27886563
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin.
    Huang HH; Lee TH
    Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Promoting bone-like apatite formation on titanium alloys through nanocrystalline tantalum nitride coatings.
    Xu J; Liu L; Munroe P; Xie ZH
    J Mater Chem B; 2015 May; 3(19):4082-4094. PubMed ID: 32262630
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrophoretic deposition of silica and its composite coatings on Ti-6Al-4V, and its in vitro corrosion behaviour for biomedical applications.
    Chellappa M; Vijayalakshmi U
    Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():879-890. PubMed ID: 27987785
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.