195 related articles for article (PubMed ID: 28777351)
1. Current Status of HbA1c Biosensors.
Lin H; Yi J
Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28777351
[TBL] [Abstract][Full Text] [Related]
2. Emerging biosensor probes for glycated hemoglobin (HbA1c) detection.
Su Y; Xia C; Zhang H; Gan W; Zhang GQ; Yang Z; Li D
Mikrochim Acta; 2024 May; 191(6):300. PubMed ID: 38709399
[TBL] [Abstract][Full Text] [Related]
3. Determination of glycated hemoglobin with special emphasis on biosensing methods.
Pundir CS; Chawla S
Anal Biochem; 2014 Jan; 444():47-56. PubMed ID: 24090871
[TBL] [Abstract][Full Text] [Related]
4. A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin.
Zhan Z; Li Y; Zhao Y; Zhang H; Wang Z; Fu B; Li WJ
Biosensors (Basel); 2022 Apr; 12(4):. PubMed ID: 35448281
[TBL] [Abstract][Full Text] [Related]
5. Point-of-care detection of glycated hemoglobin using a novel dry chemistry-based electrochemiluminescence device.
Zhou X; Lai W; Zhong J; Yang Y; Chen Z; Zhang C
Anal Chim Acta; 2023 Oct; 1279():341829. PubMed ID: 37827624
[TBL] [Abstract][Full Text] [Related]
6. Boronate-functionalized hydrogel as a novel biosensing interface for the glycated hemoglobin A1c (HbA
Han YD; Kim KR; Park YM; Song SY; Yang YJ; Lee K; Ku Y; Yoon HC
Mater Sci Eng C Mater Biol Appl; 2017 Aug; 77():1160-1169. PubMed ID: 28531992
[TBL] [Abstract][Full Text] [Related]
7. An amperometric hemoglobin A1c biosensor based on immobilization of fructosyl amino acid oxidase onto zinc oxide nanoparticles-polypyrrole film.
Chawla S; Pundir CS
Anal Biochem; 2012 Nov; 430(2):156-62. PubMed ID: 22906687
[TBL] [Abstract][Full Text] [Related]
8. An amperometric biosensor for specific detection of glycated hemoglobin based on recombinant engineered fructosyl peptide oxidase.
Shahbazmohammadi H; Sardari S; Omidinia E
Int J Biol Macromol; 2020 Jan; 142():855-865. PubMed ID: 31622711
[TBL] [Abstract][Full Text] [Related]
9. Different strategies for detection of HbA1c emphasizing on biosensors and point-of-care analyzers.
Kaur J; Jiang C; Liu G
Biosens Bioelectron; 2019 Jan; 123():85-100. PubMed ID: 29903690
[TBL] [Abstract][Full Text] [Related]
10. Hemoglobin Raleigh results in factitiously low hemoglobin A1c when evaluated via immunoassay analyzer.
Jain N; Kesimer M; Hoyer JD; Calikoglu AS
J Diabetes Complications; 2011; 25(1):14-8. PubMed ID: 19896869
[TBL] [Abstract][Full Text] [Related]
11. Analysis of Hemoglobin Glycation Using Microfluidic CE-MS: A Rapid, Mass Spectrometry Compatible Method for Assessing Diabetes Management.
Redman EA; Ramos-Payan M; Mellors JS; Ramsey JM
Anal Chem; 2016 May; 88(10):5324-30. PubMed ID: 27100069
[TBL] [Abstract][Full Text] [Related]
12. Glycated hemoglobin detection with electrochemical sensing amplified by gold nanoparticles embedded N-doped graphene nanosheet.
Jain U; Chauhan N
Biosens Bioelectron; 2017 Mar; 89(Pt 1):578-584. PubMed ID: 26897102
[TBL] [Abstract][Full Text] [Related]
13. Affinity sensor for haemoglobin A1c based on single-walled carbon nanotube field-effect transistor and fructosyl amino acid binding protein.
Hatada M; Tran TT; Tsugawa W; Sode K; Mulchandani A
Biosens Bioelectron; 2019 Mar; 129():254-259. PubMed ID: 30297174
[TBL] [Abstract][Full Text] [Related]
14. Titania nanotubes decorated with gold nanoparticles for electrochemiluminescent biosensing of glycosylated hemoglobin.
Zhao Q; Tang S; Fang C; Tu YF
Anal Chim Acta; 2016 Sep; 936():83-90. PubMed ID: 27566342
[TBL] [Abstract][Full Text] [Related]
15. Label-free electrochemical detection of glucose and glycated hemoglobin (HbA1c).
Thapa M; Heo YS
Biosens Bioelectron; 2023 Feb; 221():114907. PubMed ID: 36444798
[TBL] [Abstract][Full Text] [Related]
16. Glycated hemoglobin (HbA1c) affinity biosensors with ring-shaped interdigital electrodes on impedance measurement.
Hsieh KM; Lan KC; Hu WL; Chen MK; Jang LS; Wang MH
Biosens Bioelectron; 2013 Nov; 49():450-6. PubMed ID: 23811477
[TBL] [Abstract][Full Text] [Related]
17. Development of a flow-injection analysis (FIA) enzyme sensor for fructosyl amine monitoring.
Ogawa K; Stöllner D; Scheller F; Warsinke A; Ishimura F; Tsugawa W; Ferri S; Sode K
Anal Bioanal Chem; 2002 Jul; 373(4-5):211-4. PubMed ID: 12110969
[TBL] [Abstract][Full Text] [Related]
18. Bioelectrocatalytic detection of glycated hemoglobin (HbA1c) based on the competitive binding of target and signaling glycoproteins to a boronate-modified surface.
Song SY; Han YD; Park YM; Jeong CY; Yang YJ; Kim MS; Ku Y; Yoon HC
Biosens Bioelectron; 2012 May; 35(1):355-362. PubMed ID: 22465449
[TBL] [Abstract][Full Text] [Related]
19. Electrochemical detection of HbA1c, a marker [correction of maker] for diabetes, using a flow immunoassay system.
Tanaka T; Tsukube S; Izawa K; Okochi M; Lim TK; Watanabe S; Harada M; Matsunaga T
Biosens Bioelectron; 2007 Apr; 22(9-10):2051-6. PubMed ID: 17029779
[TBL] [Abstract][Full Text] [Related]
20. Gold nano-flowers (Au NFs) modified screen-printed carbon electrode electrochemical biosensor for label-free and quantitative detection of glycated hemoglobin.
Wang X; Su J; Zeng D; Liu G; Liu L; Xu Y; Wang C; Liu X; Wang L; Mi X
Talanta; 2019 Aug; 201():119-125. PubMed ID: 31122401
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]