These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 28779133)

  • 1. The Continuous Motion Technique for a New Generation of Scanning Systems.
    Alexandrov A; Buonaura A; Consiglio L; D'Ambrosio N; Lellis G; Crescenzo AD; Galati G; Gentile V; Lauria A; Montesi MC; Tioukov V; Vladymyrov M; Voevodina E
    Sci Rep; 2017 Aug; 7(1):7310. PubMed ID: 28779133
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous-scan capability at SSRL and applications to X-ray diffraction.
    Li C; Kiss AM; Van Campen DG; Garachtchenko A; Kolotovsky Y; Stone K; Xu Y; Zhang W; Corbett J
    J Synchrotron Radiat; 2016 Jul; 23(Pt 4):909-18. PubMed ID: 27359139
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implementation and performance evaluation of simultaneous PET/MR whole-body imaging with continuous table motion.
    Braun H; Ziegler S; Lentschig MG; Quick HH
    J Nucl Med; 2014 Jan; 55(1):161-8. PubMed ID: 24232869
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Motion artifact seen on slot-scanning direct digital mammography.
    Boyle ER; Pak D; Williams JB
    AJR Am J Roentgenol; 1999 Mar; 172(3):697-701. PubMed ID: 10063863
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implementation on a desktop computer of the real time feedback control loop of a scanning probe microscope.
    Aloisi G; Bacci F; Carlà M; Dolci D; Lanzi L
    Rev Sci Instrum; 2008 Nov; 79(11):113702. PubMed ID: 19045890
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A study on repainting strategies for treating moderately moving targets with proton pencil beam scanning at the new Gantry 2 at PSI.
    Zenklusen SM; Pedroni E; Meer D
    Phys Med Biol; 2010 Sep; 55(17):5103-21. PubMed ID: 20702927
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development and performance evaluation of a high-speed multileaf collimator.
    Zhang X; Ye P; Zhang H
    J Appl Clin Med Phys; 2017 Jan; 18(1):96-106. PubMed ID: 28291930
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Optical Scanning Technique with an Inclined Focusing Plane.
    Alexandrov A; De Lellis G; Tioukov V
    Sci Rep; 2019 Feb; 9(1):2870. PubMed ID: 30814578
    [TBL] [Abstract][Full Text] [Related]  

  • 9. First experimental results of motion mitigation by continuous line scanning of protons.
    Schätti A; Meer D; Lomax AJ
    Phys Med Biol; 2014 Oct; 59(19):5707-23. PubMed ID: 25197938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid focus map surveying for whole slide imaging with continuous sample motion.
    Liao J; Jiang Y; Bian Z; Mahrou B; Nambiar A; Magsam AW; Guo K; Wang S; Cho YK; Zheng G
    Opt Lett; 2017 Sep; 42(17):3379-3382. PubMed ID: 28957109
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
    Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
    Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fast, high bit number pattern generator for electron and ion beam lithographies.
    Pennelli G
    Rev Sci Instrum; 2008 Mar; 79(3):033902. PubMed ID: 18377020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multi-GPU implementation of a VMAT treatment plan optimization algorithm.
    Tian Z; Peng F; Folkerts M; Tan J; Jia X; Jiang SB
    Med Phys; 2015 Jun; 42(6):2841-52. PubMed ID: 26127037
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Special section on biomimetics of movement.
    Carpi F; Erb R; Jeronimidis G
    Bioinspir Biomim; 2011 Dec; 6(4):040201. PubMed ID: 22128305
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Scanning tunneling potentiometry implemented into a multi-tip setup by software.
    Lüpke F; Korte S; Cherepanov V; Voigtländer B
    Rev Sci Instrum; 2015 Dec; 86(12):123701. PubMed ID: 26724036
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three axis electronic flight motion simulator real time control system design and implementation.
    Gao Z; Miao Z; Wang X; Wang X
    Rev Sci Instrum; 2014 Dec; 85(12):125114. PubMed ID: 25554333
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of picometer-scale mirror dynamics.
    Saif B; Chaney D; Greenfield P; Bluth M; Van Gorkom K; Smith K; Bluth J; Feinberg L; Wyant JC; North-Morris M; Keski-Kuha R
    Appl Opt; 2017 Aug; 56(23):6457-6465. PubMed ID: 29047935
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and Implementation of Improved Electronic Load Controller for Self-Excited Induction Generator for Rural Electrification.
    Kathirvel C; Porkumaran K; Jaganathan S
    ScientificWorldJournal; 2015; 2015():340619. PubMed ID: 26783553
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks--comparison of a wall track system and M-mode ultrasound scanning: an in vitro and animal study.
    Schurink GW; Aarts NJ; Malina M; van Bockel JH
    J Vasc Surg; 2000 Oct; 32(4):795-803. PubMed ID: 11013044
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MEMS-based high speed scanning probe microscopy.
    Disseldorp EC; Tabak FC; Katan AJ; Hesselberth MB; Oosterkamp TH; Frenken JW; van Spengen WM
    Rev Sci Instrum; 2010 Apr; 81(4):043702. PubMed ID: 20441340
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.