These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 28779280)

  • 1. Updates in Cardiac Resynchronization Therapy for Chronic Heart Failure: Review of Multisite Pacing.
    Antoniadis AP; Sieniewicz B; Gould J; Porter B; Webb J; Claridge S; Behar JM; Rinaldi CA
    Curr Heart Fail Rep; 2017 Oct; 14(5):376-383. PubMed ID: 28779280
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multisite Pacing for Cardiac Resynchronization Therapy: Promise and Pitfalls.
    Antoniadis AP; Behar JM; Claridge S; Jackson T; Sohal M; Rinaldi CA
    Curr Cardiol Rep; 2016 Jul; 18(7):64. PubMed ID: 27216844
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of left ventricular endocardial, multisite, and multipolar epicardial cardiac resynchronization: an acute haemodynamic and electroanatomical study.
    Shetty AK; Sohal M; Chen Z; Ginks MR; Bostock J; Amraoui S; Ryu K; Rosenberg SP; Niederer SA; Gill J; Carr-White G; Razavi R; Rinaldi CA
    Europace; 2014 Jun; 16(6):873-9. PubMed ID: 24525553
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of the different features of quadripolar left ventricular pacing leads to deliver cardiac resynchronization therapy.
    Antoniadis AP; Behar JM; Sieniewicz B; Gould J; Niederer S; Rinaldi CA
    Expert Rev Med Devices; 2017 Sep; 14(9):697-706. PubMed ID: 28835138
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of Multisite Ventricular Pacing in Nonresponders to Cardiac Resynchronization Therapy.
    Saba S; Nair D; Ellis CR; Ciuffo A; Cox M; Gupta N; Sharma S; Jain S; Winner M; Mehta S; Simon T; Stein K; Ellenbogen KA;
    Am J Cardiol; 2022 Feb; 164():86-92. PubMed ID: 34815062
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Application and efficacy of the adjustment on left ventricular electrical delay and the distance between right and left ventricular pacing polar in optimizing the left ventricular pacing polar].
    Yan XL; Liang YC; Yu HB; Xu BG; Gao Y; Liu R; Xu GQ; Wu M
    Zhonghua Xin Xue Guan Bing Za Zhi; 2020 Aug; 48(8):669-674. PubMed ID: 32847323
    [No Abstract]   [Full Text] [Related]  

  • 7. Multisite left ventricular pacing in cardiac resynchronization therapy.
    Gamble JH; Betts TR
    Future Cardiol; 2014 Jul; 10(4):469-77. PubMed ID: 25301310
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Acute Effects of Multisite Biventricular Pacing on Dyssynchrony and Hemodynamics in Canines With Heart Failure.
    Qiu Q; Yang L; Mai JT; Yang Y; Xie Y; Chen YX; Wang JF
    J Card Fail; 2017 Apr; 23(4):304-311. PubMed ID: 28126497
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead.
    Thibault B; Dubuc M; Khairy P; Guerra PG; Macle L; Rivard L; Roy D; Talajic M; Karst E; Ryu K; Paiement P; Farazi TG
    Europace; 2013 Jul; 15(7):984-91. PubMed ID: 23447571
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous His Bundle and Left Ventricular Pacing for Optimal Cardiac Resynchronization Therapy Delivery: Acute Hemodynamic Assessment by Pressure-Volume Loops.
    Padeletti L; Pieragnoli P; Ricciardi G; Innocenti L; Checchi L; Padeletti M; Michelucci A; Picariello F; Valsecchi S
    Circ Arrhythm Electrophysiol; 2016 May; 9(5):. PubMed ID: 27162032
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left ventricular-only pacing in heart failure patients with normal atrioventricular conduction improves global function and left ventricular regional mechanics compared with biventricular pacing: an adaptive cardiac resynchronization therapy sub-study.
    Burns KV; Gage RM; Curtin AE; Gorcsan J; Bank AJ
    Eur J Heart Fail; 2017 Oct; 19(10):1335-1343. PubMed ID: 28653458
    [TBL] [Abstract][Full Text] [Related]  

  • 12. His-Optimized Cardiac Resynchronization Therapy to Maximize Electrical Resynchronization: A Feasibility Study.
    Vijayaraman P; Herweg B; Ellenbogen KA; Gajek J
    Circ Arrhythm Electrophysiol; 2019 Feb; 12(2):e006934. PubMed ID: 30681348
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac resynchronization therapy: results, challenges and perspectives for the future.
    Ståhlberg M; Braunschweig F; Gadler F; Mortensen L; Lund LH; Linde C
    Scand Cardiovasc J; 2016; 50(5-6):282-292. PubMed ID: 27577107
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Site of latest activation in patients eligible for cardiac resynchronization therapy: patterns of dyssynchrony among different QRS configurations and impact of heart failure etiology.
    van Bommel RJ; Ypenburg C; Mollema SA; Borleffs CJ; Delgado V; Bertini M; Marsan NA; van der Wall EE; Schalij MJ; Bax JJ
    Am Heart J; 2011 Jun; 161(6):1060-6. PubMed ID: 21641351
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Right ventricular septal pacing as alternative for failed left ventricular lead implantation in cardiac resynchronization therapy candidates.
    Alhous MH; Small GR; Hannah A; Hillis GS; Frenneaux M; Broadhurst PA
    Europace; 2015 Jan; 17(1):94-100. PubMed ID: 25359384
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac resynchronization therapy: past, present, and future.
    Chatterjee NA; Singh JP
    Heart Fail Clin; 2015 Apr; 11(2):287-303. PubMed ID: 25834976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical outcome of left ventricular multipoint pacing versus conventional biventricular pacing in cardiac resynchronization therapy: a systematic review and meta-analysis.
    Hu F; Zheng L; Ding L; Du Z; Liang E; Wu L; Chen G; Fan X; Yao Y; Jiang Y
    Heart Fail Rev; 2018 Nov; 23(6):927-934. PubMed ID: 30209643
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of left ventricular electrical delay on the acute hemodynamic response with cardiac resynchronization therapy.
    Gold MR; Leman RB; Wold N; Sturdivant JL; Yu Y
    J Cardiovasc Electrophysiol; 2014 Jun; 25(6):624-30. PubMed ID: 24446891
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cardiac responses to left ventricular pacing in hearts with normal electrical conduction: beneficial effect of improved filling is counteracted by dyssynchrony.
    Boe E; Russell K; Remme EW; Gjesdal O; Smiseth OA; Skulstad H
    Am J Physiol Heart Circ Physiol; 2014 Aug; 307(3):H370-8. PubMed ID: 24906920
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Response to cardiac resynchronization therapy is determined by intrinsic electrical substrate rather than by its modification.
    Strik M; Ploux S; Huntjens PR; Nguyên UC; Frontera A; Eschalier R; Dubois R; Ritter P; Klotz N; Vernooy K; Haïssaguerre M; Crijns HJGM; Prinzen FW; Bordachar P
    Int J Cardiol; 2018 Nov; 270():143-148. PubMed ID: 29895424
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.