These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 28788093)

  • 1. Real-Time Electrical Bioimpedance Characterization of Neointimal Tissue for Stent Applications.
    Rivas-Marchena D; Olmo A; Miguel JA; Martínez M; Huertas G; Yúfera A
    Sensors (Basel); 2017 Jul; 17(8):. PubMed ID: 28788093
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of Implanted Stents through Neointimal Tissue Bioimpedance Simulations.
    Portillo-Anaya JM; Perez P; Huertas G; Olmo A; Serrano JA; Maldonado-Jacobi A; Yufera A
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5625-5628. PubMed ID: 31947129
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Towards a self-reporting coronary artery stent--measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques.
    Shedden L; Kennedy S; Wadsworth R; Connolly P
    Biosens Bioelectron; 2010 Oct; 26(2):661-6. PubMed ID: 20667708
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chronic impedance spectroscopy of an endovascular stent-electrode array.
    Opie NL; John SE; Rind GS; Ronayne SM; Grayden DB; Burkitt AN; May CN; O'Brien TJ; Oxley TJ
    J Neural Eng; 2016 Aug; 13(4):046020. PubMed ID: 27378157
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of IVOCT imaging of coronary artery metallic stents with neointimal coverage.
    Elahi S; Ho D; Feldman MD; Dijkstra J; Milner TE
    Int J Cardiovasc Imaging; 2015 Mar; 31(3):463-70. PubMed ID: 25395364
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In-stent restenosis is associated with neointimal angiogenesis and macrophage infiltrates.
    Zhang M; Cresswell N; Tavora F; Mont E; Zhao Z; Burke A
    Pathol Res Pract; 2014 Dec; 210(12):1026-30. PubMed ID: 24815534
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of local endothelial shear stress on neointima and plaque following stent implantation in patients with ST-elevation myocardial infarction: A subgroup-analysis of the COMFORTABLE AMI-IBIS 4 trial.
    Bourantas CV; Räber L; Zaugg S; Sakellarios A; Taniwaki M; Heg D; Moschovitis A; Radu M; Papafaklis MI; Kalatzis F; Naka KK; Fotiadis DI; Michalis LK; Serruys PW; Garcia Garcia HM; Windecker S
    Int J Cardiol; 2015; 186():178-85. PubMed ID: 25828109
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neointimal tissue component assessed by tissue characterization with 40 MHz intravascular ultrasound imaging: comparison of drug-eluting stents and bare-metal stents.
    Tsujita K; Takaoka N; Kaikita K; Hokimoto S; Horio E; Sato K; Mizobe M; Nakayama N; Kojima S; Tayama S; Sugiyama S; Nakamura S; Ogawa H
    Catheter Cardiovasc Interv; 2013 Dec; 82(7):1068-74. PubMed ID: 23460385
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of optical coherence tomography- and coronary angioscopy-assessed neointimal tissue characteristics on occurrence of periprocedural myonecrosis in patients with in-stent restenosis.
    Kimura S; Sugiyama T; Hishikari K; Nakamura S; Nakagama S; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Sagawa Y; Kojima K; Ohtani H; Hikita H; Takahashi A; Isobe M
    Int J Cardiovasc Imaging; 2016 Oct; 32(10):1483-94. PubMed ID: 27423209
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differences in tissue characterization of restenotic neointima between sirolimus-eluting stent and bare-metal stent: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.
    Ando H; Amano T; Takashima H; Harada K; Kitagawa K; Suzuki A; Kunimura A; Shimbo Y; Harada K; Yoshida T; Kato B; Uetani T; Kato M; Matsubara T; Kumagai S; Yoshikawa D; Isobe S; Ishii H; Murohara T
    Eur Heart J Cardiovasc Imaging; 2013 Oct; 14(10):996-1001. PubMed ID: 23341147
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cutting balloon combined with paclitaxel-eluting balloon for treatment of in-stent restenosis.
    Kong J; Hou J; Ma L; Xing L; Jia H; Liu H; Zhang S; Yu B; Jang IK
    Arch Cardiovasc Dis; 2013 Feb; 106(2):79-85. PubMed ID: 23527911
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neointimal patterns obtained by optical coherence tomography correlate with specific histological components and neointimal proliferation in a swine model of restenosis.
    Kim JS; Afari ME; Ha J; Tellez A; Milewski K; Conditt G; Cheng Y; Hua Yi G; Kaluza GL; Granada JF
    Eur Heart J Cardiovasc Imaging; 2014 Mar; 15(3):292-8. PubMed ID: 24022066
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In silico prediction of the mechanobiological response of arterial tissue: application to angioplasty and stenting.
    Boyle CJ; Lennon AB; Prendergast PJ
    J Biomech Eng; 2011 Aug; 133(8):081001. PubMed ID: 21950894
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Periluminal expression of a secreted transforming growth factor-β type II receptor inhibits in-stent neointima formation following adenovirus-mediated stent-based intracoronary gene transfer.
    Appleby CE; Ranjzad P; Williams PD; Kakar SJ; Driessen A; Tijsma E; Fernandes B; Heagerty AM; Kingston PA
    Hum Gene Ther; 2014 May; 25(5):443-51. PubMed ID: 24483849
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Segmental vessel wall shear stress and neointimal formation after sirolimus-eluting stent implantation: physiological insights in a porcine coronary model.
    Carter AJ; Wei W; Gibson L; Collingwood R; Tio F; Dooley J; Kopia GA
    Cardiovasc Revasc Med; 2005; 6(2):58-64. PubMed ID: 16263360
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.
    Fu Q; Hu H; Chen W; Tan Z; Li L; Wang D; Chen B
    Int J Clin Exp Pathol; 2015; 8(9):11068-75. PubMed ID: 26617825
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ex vivo assessment of neointimal characteristics after drug-eluting stent implantation: Optical coherence tomography and histopathology validation study.
    Imanaka T; Fujii K; Hao H; Shibuya M; Saita T; Kawakami R; Fukunaga M; Kawai K; Tamaru H; Miki K; Horimatsu T; Sumiyoshi A; Nishimura M; Hirota S; Masuyama T; Ishihara M
    Int J Cardiol; 2016 Oct; 221():1043-7. PubMed ID: 27447812
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vascular response and mechanical integrity of the new biodegradable polymer coated sirolimus-eluting PROLIM stent implanted in porcine coronary arteries.
    Milewski K; Gorycki B; Buszman PP; Jelonek M; Beaudry D; Lapointe JM; Guy LG; Abusamra M; Pająk J; Kinasz W; Wojakowski W; Leclerc G; Gil RJ; Buszman PE
    Kardiol Pol; 2012; 70(7):703-11. PubMed ID: 22825946
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of Early Healing Profile and Neointimal Transformation Over 24 Months Using Longitudinal Sequential Optical Coherence Tomography Assessments and 3-Year Clinical Results of the New Dual-Therapy Endothelial Progenitor Cell Capturing Sirolimus-Eluting Combo Stent: The EGO-Combo Study.
    Lee SW; Lam SC; Tam FC; Chan KK; Shea CP; Kong SL; Wong AY; Yung A; Zhang LW; Tse HF; Wu KK; Chan R; Haude M; Mehran R; Mintz GS; Maehara A
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27418609
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.