These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

439 related articles for article (PubMed ID: 28791567)

  • 1. The oxygen reserve index (ORI): a new tool to monitor oxygen therapy.
    Scheeren TWL; Belda FJ; Perel A
    J Clin Monit Comput; 2018 Jun; 32(3):379-389. PubMed ID: 28791567
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Oxygen reserve index, a new method of monitoring oxygenation status: what do we need to know?
    Chen ST; Min S
    Chin Med J (Engl); 2020 Jan; 133(2):229-234. PubMed ID: 31904726
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ORi™: a new indicator of oxygenation.
    Ishida Y; Okada T; Kobayashi T; Uchino H
    J Anesth; 2021 Oct; 35(5):734-740. PubMed ID: 33900455
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Oxygen reserve index: a new parameter for oxygen therapy].
    Zou YS; Zhou XG
    Zhongguo Dang Dai Er Ke Za Zhi; 2022 Nov; 24(11):1275-1280. PubMed ID: 36398556
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Perioperative monitoring of the oxygen reserve: where do we stand?
    Massari D; de Keijzer IN; Vos JJ
    J Clin Monit Comput; 2023 Dec; 37(6):1431-1433. PubMed ID: 37863861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery.
    Applegate RL; Dorotta IL; Wells B; Juma D; Applegate PM
    Anesth Analg; 2016 Sep; 123(3):626-33. PubMed ID: 27007078
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Non-invasive assessment of oxygenation status using the oxygen reserve index in dogs.
    Zanusso F; De Benedictis GM; Zemko P; Bellini L
    BMC Vet Res; 2023 Nov; 19(1):241. PubMed ID: 37980491
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The ability of Oxygen Reserve Index® to detect hyperoxia in critically ill patients.
    de Courson H; Julien-Laferrière T; Georges D; Boyer P; Verchère E; Biais M
    Ann Intensive Care; 2022 May; 12(1):40. PubMed ID: 35576087
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Usefulness of oxygen reserve index (ORi™), a new parameter of oxygenation reserve potential, for rapid sequence induction of general anesthesia.
    Yoshida K; Isosu T; Noji Y; Hasegawa M; Iseki Y; Oishi R; Imaizumi T; Sanbe N; Obara S; Murakawa M
    J Clin Monit Comput; 2018 Aug; 32(4):687-691. PubMed ID: 28956237
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Oxygen Reserve Index: Validation of a New Variable.
    Vos JJ; Willems CH; van Amsterdam K; van den Berg JP; Spanjersberg R; Struys MMRF; Scheeren TWL
    Anesth Analg; 2019 Aug; 129(2):409-415. PubMed ID: 30138170
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Adjustment of oxygen reserve index (ORi™) to avoid excessive hyperoxia during general anesthesia.
    Yoshida K; Isosu T; Noji Y; Ebana H; Honda J; Sanbe N; Obara S; Murakawa M
    J Clin Monit Comput; 2020 Jun; 34(3):509-514. PubMed ID: 31227971
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How early warning with the Oxygen Reserve Index (ORi™) can improve the detection of desaturation during induction of general anesthesia?
    Cheng HW; Yeh CY; Chang MY; Ting CK; Chang PL
    J Clin Monit Comput; 2022 Oct; 36(5):1379-1385. PubMed ID: 34953137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Alarm settings for the Marquette 8000 pulse oximeter to prevent hyperoxic and hypoxic episodes.
    Cust AE; Donovan TJ; Colditz PB
    J Paediatr Child Health; 1999 Apr; 35(2):159-62. PubMed ID: 10365353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Oxygen Reserve Index: Utility as an Early Warning for Desaturation in High-Risk Surgical Patients.
    Fleming NW; Singh A; Lee L; Applegate RL
    Anesth Analg; 2021 Mar; 132(3):770-776. PubMed ID: 32815872
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early warning for SpO
    Wittenmeier E; Schmidtmann I; Heese P; Müller P; Didion N; Kriege M; Komorek Y; Pirlich N
    Paediatr Anaesth; 2023 Nov; 33(11):923-929. PubMed ID: 37551627
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hyperoxia: At what level of SpO
    Durlinger EMJ; Spoelstra-de Man AME; Smit B; de Grooth HJ; Girbes ARJ; Oudemans-van Straaten HM; Smulders YM
    J Crit Care; 2017 Jun; 39():199-204. PubMed ID: 28279497
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of pulse oximetry in the intensive care unit.
    Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L
    Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Study of early warning for desaturation provided by Oxygen Reserve Index in obese patients.
    Tsymbal E; Ayala S; Singh A; Applegate RL; Fleming NW
    J Clin Monit Comput; 2021 Aug; 35(4):749-756. PubMed ID: 32424516
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thresholds for oximetry alarms and target range in the NICU: an observational assessment based on likely oxygen tension and maturity.
    Bachman TE; Iyer NP; Newth CJL; Ross PA; Khemani RG
    BMC Pediatr; 2020 Jun; 20(1):317. PubMed ID: 32593300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Oxygen therapy in critical illness: precise control of arterial oxygenation and permissive hypoxemia.
    Martin DS; Grocott MP
    Crit Care Med; 2013 Feb; 41(2):423-32. PubMed ID: 23263574
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.