These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
154 related articles for article (PubMed ID: 28799273)
1. Sensitivity of array detector measurements in determining shifts of MLC leaf positions. Shang Q; Godley A; Huang L; Qi P; Xia P J Appl Clin Med Phys; 2017 Sep; 18(5):80-88. PubMed ID: 28799273 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system. Karagoz G; Zorlu F; Yeginer M; Yildiz D; Ozyigit G J Appl Clin Med Phys; 2016 Mar; 17(2):14-23. PubMed ID: 27074451 [TBL] [Abstract][Full Text] [Related]
3. Development of an iterative reconstruction method to overcome 2D detector low resolution limitations in MLC leaf position error detection for 3D dose verification in IMRT. Visser R; Godart J; Wauben DJ; Langendijk JA; Van't Veld AA; Korevaar EW Phys Med Biol; 2016 May; 61(10):3843-56. PubMed ID: 27100169 [TBL] [Abstract][Full Text] [Related]
4. On the sensitivity of patient-specific IMRT QA to MLC positioning errors. Yan G; Liu C; Simon TA; Peng LC; Fox C; Li JG J Appl Clin Med Phys; 2009 Feb; 10(1):120-128. PubMed ID: 19223841 [TBL] [Abstract][Full Text] [Related]
5. Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT. Visser R; Godart J; Wauben DJ; Langendijk JA; Van't Veld AA; Korevaar EW Phys Med Biol; 2016 Dec; 61(23):N642-N649. PubMed ID: 27819251 [TBL] [Abstract][Full Text] [Related]
6. Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and correlation to dose volume histogram based metrics. Coleman L; Skourou C Med Phys; 2013 Nov; 40(11):111715. PubMed ID: 24320423 [TBL] [Abstract][Full Text] [Related]
7. A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA. Woon W; Ravindran PB; Ekayanake P; S V; Lim YY; Khalid J J Appl Clin Med Phys; 2018 Mar; 19(2):230-248. PubMed ID: 29460465 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID. Mohammadi M; Bezak E Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123 [TBL] [Abstract][Full Text] [Related]
9. Clinical implementation and error sensitivity of a 3D quality assurance protocol for prostate and thoracic IMRT. Gueorguiev G; Cotter C; Turcotte JC; Crawford B; Sharp G; Mah'D M J Appl Clin Med Phys; 2015 Sep; 16(5):179–192. PubMed ID: 26699299 [TBL] [Abstract][Full Text] [Related]
10. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning. Yang Y; Xing L Med Phys; 2003 Mar; 30(3):433-41. PubMed ID: 12674244 [TBL] [Abstract][Full Text] [Related]
11. Biological consequences of MLC calibration errors in IMRT delivery and QA. Moiseenko V; Lapointe V; James K; Yin L; Liu M; Pawlicki T Med Phys; 2012 Apr; 39(4):1917-24. PubMed ID: 22482613 [TBL] [Abstract][Full Text] [Related]
12. A novel method for routine quality assurance of volumetric-modulated arc therapy. Wang Q; Dai J; Zhang K Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902 [TBL] [Abstract][Full Text] [Related]
13. An error detection method for real-time EPID-based treatment delivery quality assurance. Alves VGL; Ahmed M; Aliotta E; Choi W; Siebers JV Med Phys; 2021 Feb; 48(2):569-578. PubMed ID: 33314247 [TBL] [Abstract][Full Text] [Related]
14. Impact of leaf motion constraints on IMAT plan quality, deliver accuracy, and efficiency. Chen F; Rao M; Ye JS; Shepard DM; Cao D Med Phys; 2011 Nov; 38(11):6106-18. PubMed ID: 22047375 [TBL] [Abstract][Full Text] [Related]
15. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation. Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942 [TBL] [Abstract][Full Text] [Related]
16. Characterization of positional accuracy of a double-focused and double-stack multileaf collimator on an MR-guided radiotherapy (MRgRT) Linac using an IC-profiler array. Mittauer KE; Yadav P; Paliwal B; Bayouth JE Med Phys; 2020 Feb; 47(2):317-330. PubMed ID: 31682018 [TBL] [Abstract][Full Text] [Related]
17. [Influence of high-definition multileaf collimator for three-dimensional conformal radiotherapy and intensity-modulated radiotherapy of prostate cancer]. Fujimoto S; Ono K; Furukawa K; Kudo T; Akagi Y; Koyama T; Hirokawa Y; Kawai S; Nakashima T Nihon Hoshasen Gijutsu Gakkai Zasshi; 2012; 68(7):825-34. PubMed ID: 22821155 [TBL] [Abstract][Full Text] [Related]
18. Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system. Nithiyanantham K; Mani GK; Subramani V; Mueller L; Palaniappan KK; Kataria T J Appl Clin Med Phys; 2015 Sep; 16(5):296–305. PubMed ID: 26699311 [TBL] [Abstract][Full Text] [Related]
19. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation. Li T; Wu Q; Yang Y; Rodrigues A; Yin FF; Jackie Wu Q Med Phys; 2015 Jan; 42(1):381-90. PubMed ID: 25563278 [TBL] [Abstract][Full Text] [Related]
20. Implementation of phantom-less IMRT delivery verification using Varian DynaLog files and R/V output. Agnew CE; King RB; Hounsell AR; McGarry CK Phys Med Biol; 2012 Nov; 57(21):6761-77. PubMed ID: 23032423 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]