BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

663 related articles for article (PubMed ID: 28800985)

  • 1. Assessment of Paravalvular Leak After Transcatheter Aortic Valve Replacement: Transesophageal Echocardiography Compared With Transthoracic Echocardiography.
    Teeter EG; Dakik C; Cooter M; Samad Z; Ghadimi K; Harrison JK; Gaca J; Stafford-Smith M; Bottiger BA
    J Cardiothorac Vasc Anesth; 2017 Aug; 31(4):1278-1284. PubMed ID: 28800985
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Evolution of Echocardiographic Type and Anesthetic Technique for Transcatheter Aortic Valve Replacement at a High-Volume Transcatheter Aortic Valve Replacement Center.
    Marino M; Lilie CJ; Culp WC; Schepel SR; Tippett JC
    J Cardiothorac Vasc Anesth; 2019 Jan; 33(1):29-35. PubMed ID: 30087025
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative Transesophageal and Postoperative Transthoracic Echocardiographic Evaluation of a Mechanical Heart Valve Prosthesis Implanted at Aortic Position.
    Babu S; Sreedhar R; Gadhinglajkar SV; Dash PK; Sukesan S; Pillai V; Panicker VT; Shriram LP; Aggarwal N
    J Cardiothorac Vasc Anesth; 2018 Apr; 32(2):782-789. PubMed ID: 29217244
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Comparing Transthoracic versus Transesophageal Echocardiographic Guidance.
    Hayek SS; Corrigan FE; Condado JF; Lin S; Howell S; MacNamara JP; Spilias N; Zheng S; Keegan P; Thourani V; Babaliaros VC; Lerakis S
    J Am Soc Echocardiogr; 2017 Jun; 30(6):533-540. PubMed ID: 28391002
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality.
    Schoechlin S; Brennemann T; Allali A; Ruile P; Jander N; Allgeier M; Gick M; Richardt G; Neumann FJ; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2018 May; 91(6):E56-E63. PubMed ID: 29105984
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Paravalvular leak after transcatheter aortic valve implantation (TAVI): Short-term results. Data from Polish national POL-TAVI registry.
    Kleczyński P; Zasada W; Bagieński M; Rzeszutko Ł; Sorysz D; Sobczyński R; Trębacz J; Kapelak B; Zembala M; Dudek D
    Cardiol J; 2016; 23(2):163-8. PubMed ID: 26503080
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of transthoracic and transesophageal echocardiography for transcatheter aortic valve replacement sizing in high-risk patients.
    Fox H; Hemmann K; Lehmann R
    J Echocardiogr; 2020 Mar; 18(1):47-56. PubMed ID: 31630329
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Grading Aortic Stenosis With Mean Gradient and Aortic Valve Area: A Comparison Between Preoperative Transthoracic and Precardiopulmonary Bypass Transesophageal Echocardiography.
    Whitener G; Sivak J; Akushevich I; Samad Z; Swaminathan M
    J Cardiothorac Vasc Anesth; 2016 Oct; 30(5):1254-9. PubMed ID: 27495962
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intra-procedural monitoring protocol using routine transthoracic echocardiography with backup trans-oesophageal probe in transcatheter aortic valve replacement: a single centre experience.
    Stella S; Melillo F; Capogrosso C; Fisicaro A; Ancona F; Latib A; Montorfano M; Colombo A; Alfieri O; Castiglioni A; Margonato A; Agricola E
    Eur Heart J Cardiovasc Imaging; 2020 Jan; 21(1):85-92. PubMed ID: 30977790
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional printing for assessment of paravalvular leak in transcatheter aortic valve implantation.
    Thorburn C; Abdel-Razek O; Fagan S; Pearce N; Furey M; Harris S; Bartellas M; Adams C
    J Cardiothorac Surg; 2020 Aug; 15(1):211. PubMed ID: 32758268
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictors of Paravalvular Regurgitation After Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (from the REPRISE II Trial Extended Cohort).
    Blackman DJ; Meredith IT; Dumonteil N; Tchétché D; Hildick-Smith D; Spence MS; Walters DL; Harnek J; Worthley SG; Rioufol G; Lefèvre T; Houle VM; Allocco DJ; Dawkins KD
    Am J Cardiol; 2017 Jul; 120(2):292-299. PubMed ID: 28535962
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does pre-existing aortic regurgitation protect from death in patients who develop paravalvular leak after TAVI?
    Colli A; Besola L; Salizzoni S; Gregori D; Tarantini G; Agrifoglio M; Chieffo A; Regesta T; Gabbieri D; Saia F; Tamburino C; Ribichini F; Valsecchi O; Loi B; Iadanza A; Stolcova M; Minati A; Martinelli G; Bedogni F; Petronio A; Dallago M; Cappai A; D'Onofrio A; Gerosa G; Rinaldi M
    Int J Cardiol; 2017 Apr; 233():52-60. PubMed ID: 28188002
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Grading Aortic Valve Stenosis With Dimensionless Index During Pre-cardiopulmonary Bypass Transesophageal Echocardiography: A Comparison With Transthoracic Echocardiography.
    Whitener GB; Shanahan PC; Wolf BJ; Finley AC
    J Cardiothorac Vasc Anesth; 2019 Sep; 33(9):2376-2384. PubMed ID: 31097337
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Erroneous measurement of the aortic annular diameter using 2-dimensional echocardiography resulting in inappropriate CoreValve size selection: a retrospective comparison with multislice computed tomography.
    Mylotte D; Dorfmeister M; Elhmidi Y; Mazzitelli D; Bleiziffer S; Wagner A; Noterdaeme T; Lange R; Piazza N
    JACC Cardiovasc Interv; 2014 Jun; 7(6):652-61. PubMed ID: 24947721
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of grading of aortic stenosis between transthoracic and transesophageal echocardiography in adult patients undergoing elective aortic valve replacement surgeries: A prospective observational study.
    Nanditha S; Malik V; Hasija S; Malhotra P; Sreenivas V; Chauhan S
    Ann Card Anaesth; 2019; 22(2):194-198. PubMed ID: 30971602
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Can we predict postprocedural paravalvular leak after Edwards SAPIEN transcatheter aortic valve implantation?
    Watanabe Y; Lefèvre T; Arai T; Hayashida K; Bouvier E; Hovasse T; Romano M; Chevalier B; Garot P; Donzeau-Gouge P; Farge A; Cormier B; Morice MC
    Catheter Cardiovasc Interv; 2015 Jul; 86(1):144-51. PubMed ID: 25205469
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of CoreValve size selection based on multi-slice computed tomography on paravalvular leak after transcatheter aortic valve implantation.
    Chodór P; Wilczek K; Przybylski R; Głowacki J; Kukulski T; Streb W; Niklewski T; Honisz G; Trzeciak P; Podolecki T; Włoch Ł; Zembala M; Kalarus Z
    Cardiol J; 2017; 24(5):467-476. PubMed ID: 28150295
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Techniques and outcomes of paravalvular leak repair after transcatheter aortic valve replacement.
    Waterbury TM; Reeder GS; Pislaru SV; Cabalka AK; Rihal CS; Eleid MF
    Catheter Cardiovasc Interv; 2017 Nov; 90(5):870-877. PubMed ID: 28766839
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transthoracic Echocardiography to Assess Aortic Regurgitation after TAVR: A Comparison with Periprocedural Transesophageal Echocardiography.
    Goncalves A; Nyman C; Okada DR; Singh A; Swanson J; Cheezum M; Steigner M; Di Carli M; Solomon S; Shah PB; Bhatt DL; Shook D; Blankstein R
    Cardiology; 2017; 137(1):1-8. PubMed ID: 27925612
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Paravalvular leak after transcatheter aortic valve implantation: is it anatomically predictable or procedurally determined? MDCT study.
    Sakrana AA; Nasr MM; Ashamallah GA; Abuelatta RA; Naeim HA; Tahlawi ME
    Clin Radiol; 2016 Nov; 71(11):1095-103. PubMed ID: 27612848
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 34.