242 related articles for article (PubMed ID: 28803112)
1. In vivo documentation of shape and position changes of MRI-visible mesh placed in rectovaginal septum.
Iva U; Nikhil S; Geertje C; Alice T; Rynkevic R; Lucie H; Andrew F; Jan D
J Mech Behav Biomed Mater; 2017 Nov; 75():379-389. PubMed ID: 28803112
[TBL] [Abstract][Full Text] [Related]
2. Short term post-operative morphing of sacrocolpopexy mesh measured by magnetic resonance imaging.
Sindhwani N; Callewaert G; Deprest T; Housmans S; Van Beckevoort D; Deprest J
J Mech Behav Biomed Mater; 2018 Apr; 80():269-276. PubMed ID: 29455036
[TBL] [Abstract][Full Text] [Related]
3. Three-dimensional analysis of implanted magnetic-resonance-visible meshes.
Sindhwani N; Feola A; De Keyzer F; Claus F; Callewaert G; Urbankova I; Ourselin S; D'hooge J; Deprest J
Int Urogynecol J; 2015 Oct; 26(10):1459-65. PubMed ID: 25800904
[TBL] [Abstract][Full Text] [Related]
4. Changes in pelvic organ prolapse mesh mechanical properties following implantation in rats.
Ulrich D; Edwards SL; Alexander DLJ; Rosamilia A; Werkmeister JA; Gargett CE; Letouzey V
Am J Obstet Gynecol; 2016 Feb; 214(2):260.e1-260.e8. PubMed ID: 26348376
[TBL] [Abstract][Full Text] [Related]
5. Host reaction to vaginally inserted collagen containing polypropylene implants in sheep.
Feola A; Endo M; Urbankova I; Vlacil J; Deprest T; Bettin S; Klosterhalfen B; Deprest J
Am J Obstet Gynecol; 2015 Apr; 212(4):474.e1-8. PubMed ID: 25446700
[TBL] [Abstract][Full Text] [Related]
6. Immediate postoperative changes in synthetic meshes - In vivo measurements.
Sindhwani N; Liaquat Z; Urbankova I; Vande Velde G; Feola A; Deprest J
J Mech Behav Biomed Mater; 2015 Mar; 55():228-235. PubMed ID: 26594782
[TBL] [Abstract][Full Text] [Related]
7. Tissue response to collagen containing polypropylene meshes in an ovine vaginal repair model.
Darzi S; Urbankova I; Su K; White J; Lo C; Alexander D; Werkmeister JA; Gargett CE; Deprest J
Acta Biomater; 2016 Jul; 39():114-123. PubMed ID: 27163402
[TBL] [Abstract][Full Text] [Related]
8. Assessment of Electrospun and Ultra-lightweight Polypropylene Meshes in the Sheep Model for Vaginal Surgery.
Hympánová L; Rynkevic R; Román S; Mori da Cunha MGMC; Mazza E; Zündel M; Urbánková I; Gallego MR; Vange J; Callewaert G; Chapple C; MacNeil S; Deprest J
Eur Urol Focus; 2020 Jan; 6(1):190-198. PubMed ID: 30049658
[TBL] [Abstract][Full Text] [Related]
9. Comparison of 2 single incision slings on the vagina in an ovine model.
Shapiro KK; Knight KM; Liang R; Cook J; King GE; Abramowitch SD; Moalli PA
Am J Obstet Gynecol; 2021 Jan; 224(1):78.e1-78.e7. PubMed ID: 32707267
[TBL] [Abstract][Full Text] [Related]
10. Extracellular matrix regenerative graft attenuates the negative impact of polypropylene prolapse mesh on vagina in rhesus macaque.
Liang R; Knight K; Barone W; Powers RW; Nolfi A; Palcsey S; Abramowitch S; Moalli PA
Am J Obstet Gynecol; 2017 Feb; 216(2):153.e1-153.e9. PubMed ID: 27615441
[TBL] [Abstract][Full Text] [Related]
11. Mesh deformation: A mechanism underlying polypropylene prolapse mesh complications in vivo.
Knight KM; King GE; Palcsey SL; Suda A; Liang R; Moalli PA
Acta Biomater; 2022 Aug; 148():323-335. PubMed ID: 35671876
[TBL] [Abstract][Full Text] [Related]
12. Graft-related complications and biaxial tensiometry following experimental vaginal implantation of flat mesh of variable dimensions.
Manodoro S; Endo M; Uvin P; Albersen M; Vláčil J; Engels A; Schmidt B; De Ridder D; Feola A; Deprest J
BJOG; 2013 Jan; 120(2):244-250. PubMed ID: 23240803
[TBL] [Abstract][Full Text] [Related]
13. Ultrasound visualization of sacrocolpopexy polyvinylidene fluoride meshes containing paramagnetic Fe particles compared with polypropylene mesh.
Eisenberg VH; Callewaert G; Sindhwani N; Housmans S; van Schoubroeck D; Lowenstein L; Deprest J
Int Urogynecol J; 2019 May; 30(5):795-804. PubMed ID: 30083941
[TBL] [Abstract][Full Text] [Related]
14. Textile properties of synthetic prolapse mesh in response to uniaxial loading.
Barone WR; Moalli PA; Abramowitch SD
Am J Obstet Gynecol; 2016 Sep; 215(3):326.e1-9. PubMed ID: 27001219
[TBL] [Abstract][Full Text] [Related]
15. Nanofibrous biomimetic mesh can be used for pelvic reconstructive surgery: A randomized study.
Ding J; Deng M; Song XC; Chen C; Lai KL; Wang GS; Yuan YY; Xu T; Zhu L
J Mech Behav Biomed Mater; 2016 Aug; 61():26-35. PubMed ID: 26820994
[TBL] [Abstract][Full Text] [Related]
16. 3D reconstruction of MR-visible Fe
Brocker KA; Mokry T; Alt CD; Kauczor HU; Lenz F; Sohn C; DeLancey JO; Chen L
Neurourol Urodyn; 2019 Jan; 38(1):369-378. PubMed ID: 30387537
[TBL] [Abstract][Full Text] [Related]
17. [Current state of transvaginal meshes by resolution of pelvic organ prolapse].
Jírová J; Pán M
Ceska Gynekol; 2017; 82(1):72-78. PubMed ID: 28252314
[TBL] [Abstract][Full Text] [Related]
18. Mesh contraction: in vivo documentation of changes in apparent surface area utilizing meshes visible on magnetic resonance imaging in the rabbit abdominal wall model.
Endo M; Feola A; Sindhwani N; Manodoro S; Vlacil J; Engels AC; Claus F; Deprest JA
Int Urogynecol J; 2014 Jun; 25(6):737-43. PubMed ID: 24448724
[TBL] [Abstract][Full Text] [Related]
19. Evaluating Alternative Materials for the Treatment of Stress Urinary Incontinence and Pelvic Organ Prolapse: A Comparison of the In Vivo Response to Meshes Implanted in Rabbits.
Roman S; Urbánková I; Callewaert G; Lesage F; Hillary C; Osman NI; Chapple CR; Deprest J; MacNeil S
J Urol; 2016 Jul; 196(1):261-9. PubMed ID: 26880411
[TBL] [Abstract][Full Text] [Related]
20. Deformation of Transvaginal Mesh in Response to Multiaxial Loading.
Barone WR; Knight KM; Moalli PA; Abramowitch SD
J Biomech Eng; 2019 Feb; 141(2):0210011-8. PubMed ID: 30347035