  • 1. [Effects of Different Containers on Radioactivity Measurements using a Dose Calibrator with Special Reference to
    Inoue Y; Abe Y; Kikuchi K; Miyatake H; Watanabe A
    Kaku Igaku; 2017; 54(1):545-549. PubMed ID: 28804109
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dose calibrator assay of iodine-123 and indium-111 with a copper filter.
    Kowalsky RJ; Johnston RE
    J Nucl Med Technol; 1998 Jun; 26(2):94-8. PubMed ID: 9604830
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of characteristic x-rays on assay of I-123 by dose calibrator.
    Harris CC; Jaszczak RJ; Greer KL; Briner WH; Coleman RE
    J Nucl Med; 1984 Dec; 25(12):1367-70. PubMed ID: 6502258
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes.
    Mushtaq A; Ur Rehman T; Safdar Mansur M; Jehangir M
    J Nucl Med Technol; 2008 Jun; 36(2):91-4. PubMed ID: 18483140
    [TBL] [Abstract][Full Text] [Related]  

  • 5. NPL secondary standard radionuclide calibrator. Syringe calibration factors for radionuclides used in nuclear medicine. National Physical Laboratory.
    Tyler DK; Baker M; Woods MJ
    Appl Radiat Isot; 2002; 56(1-2):343-7. PubMed ID: 11839039
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Survey of the performance of commercial dose calibrators for measurement of ¹²³I activity.
    Jacobson AF; Centofanti R; Babalola OI; Dean B
    J Nucl Med Technol; 2011 Dec; 39(4):302-6. PubMed ID: 21875924
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radioassay of yttrium-90 radiation using the radionuclide dose calibrator.
    Salako QA; DeNardo SJ
    J Nucl Med; 1997 May; 38(5):723-6. PubMed ID: 9170436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dose variance associated with calibration and administration of radiopharmaceuticals.
    Dansereau RN; Methe BM
    Am J Health Syst Pharm; 2001 Apr; 58(7):580-4. PubMed ID: 11296606
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Feasibility study of radioactivity estimation of
    Nakamura Y; Yasuno N
    Radiol Phys Technol; 2024 Jun; 17(2):396-401. PubMed ID: 38517669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Syringe calibration factors for the NPL Secondary Standard Radionuclide Calibrator for selected medical radionuclides.
    Tyler DK; Woods MJ
    Appl Radiat Isot; 2003; 59(5-6):367-72. PubMed ID: 14622937
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of varying geometry on dose calibrator response: cobalt-57 and technetium-99m.
    Calhoun JM; Golas DB; Harris SG
    J Nucl Med; 1987 Sep; 28(9):1478-83. PubMed ID: 3625300
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental determination of dose calibrator settings and study of associated volume dependence in v-vials for rhenium-186 perrhenate solution sources.
    Zimmerman BE; Pipes DW
    J Nucl Med Technol; 2000 Dec; 28(4):264-70. PubMed ID: 11142329
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Counting efficiency of a double-well single-plastic scintillation counter to commercially available radionuclides (Tl-201, Tc-99m, I-123, Ga-67, In-111 and I-131).
    Itoh K; Sasaki K
    Ann Nucl Med; 2003 Jul; 17(5):375-80. PubMed ID: 12971635
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental determination of calibration settings of a commercially available radionuclide calibrator for various clinical measurement geometries and radionuclides.
    Ceccatelli A; Benassi M; D'Andrea M; De Felice P; Fazio A; Nocentini S; Strigari L
    Appl Radiat Isot; 2007 Jan; 65(1):120-5. PubMed ID: 16996744
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Resin 90Y microsphere activity measurements for liver brachytherapy.
    Dezarn WA; Kennedy AS
    Med Phys; 2007 Jun; 34(6):1896-900. PubMed ID: 17654890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intercomparison of
    Saldarriaga Vargas C; Rodríguez Pérez S; Baete K; Pommé S; Paepen J; Van Ammel R; Struelens L
    Phys Med; 2018 Jan; 45():134-142. PubMed ID: 29472078
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stability of stabilized 99mTc-D,L-HMPAO stored in vials and syringes.
    Del Carmen Plancha-Mansanet M; Caballero-Calabuig E; Félix-Fontestad J; Reyes-Ojeda MD; Sopena-Novales P; Abreu-Sánchez P; Del Carmen Cano-Terol M; Sopena-Monforte R
    J Nucl Med Technol; 2008 Dec; 36(4):213-6. PubMed ID: 19008289
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radionuclide calibrator intercomparison study of clinical PET centres in England to a single traceable 68Ge syringe source.
    Sanghera B; Fenwick A; Lowe G; Sullivan K; Wong WL
    Nucl Med Commun; 2020 Sep; 41(9):965-976. PubMed ID: 32796486
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simple and effective technique to reduce staff exposure during the preparation of radiopharmaceuticals.
    Tsopelas C; Collins PJ; Blefari C
    J Nucl Med Technol; 2003 Mar; 31(1):37-40. PubMed ID: 12624127
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of radiation source geometry on determination of (111)In and (90)Y activity of radiopharmaceuticals.
    Peitl PK; Tomse P; Kroselj M; Socan A; Hojker S; Pecar S; Stopar TG
    Nucl Med Commun; 2009 Oct; 30(10):807-14. PubMed ID: 19623093
    [TBL] [Abstract][Full Text] [Related]  