These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 28804141)

  • 21. Optimal resonance configuration for ultrasonic wireless power transmission to millimeter-sized biomedical implants.
    Miao Meng ; Kiani M
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():1934-1937. PubMed ID: 28268706
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A parallel-architecture parametric equalizer for air-coupled capacitive ultrasonic transducers.
    McSweeney SG; Wright WM
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jan; 59(1):90-7. PubMed ID: 22293739
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An equivalent circuit model for transmitting capacitive micromachined ultrasonic transducers in collapse mode.
    Olcum S; Yamaner FY; Bozkurt A; Köymen H; Atalar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jul; 58(7):1468-77. PubMed ID: 21768031
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Capacitive Micromachined Ultrasonic Transducers (CMUTs) for Underwater Imaging Applications.
    Song J; Xue C; He C; Zhang R; Mu L; Cui J; Miao J; Liu Y; Zhang W
    Sensors (Basel); 2015 Sep; 15(9):23205-17. PubMed ID: 26389902
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Unbiased Charged Circular CMUT Microphone: Lumped-Element Modeling and Performance.
    Koymen H; Atalar A; Guler S; Koymen I; Tasdelen AS; Unlugedik A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Jan; 65(1):60-71. PubMed ID: 29283348
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Frequency Tuning of Collapse-Mode Capacitive Micromachined Ultrasonic Transducer.
    Pekař M; Dittmer WU; Mihajlović N; van Soest G; de Jong N
    Ultrasonics; 2017 Feb; 74():144-152. PubMed ID: 27780034
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers.
    Yaralioglu GG; Ergun AS; Bayram B; Haeggström E; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Apr; 50(4):449-56. PubMed ID: 12744401
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Air-coupled MUMPs capacitive micromachined ultrasonic transducers with resonant cavities.
    Octavio Manzanares A; Montero de Espinosa F
    Ultrasonics; 2012 Apr; 52(4):482-9. PubMed ID: 22099252
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A three-mask process for fabricating vacuum-sealed capacitive micromachined ultrasonic transducers using anodic bonding.
    Yamaner FY; Zhang X; Oralkan Ö
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 May; 62(5):972-82. PubMed ID: 25965687
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An Ultrasonic Laminated Transducer for Viscoelastic Media Detection.
    Yang S; Song W; Chen Y; Yang L; Wang M; Lian Y; Liu K
    Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770495
    [TBL] [Abstract][Full Text] [Related]  

  • 31. High-Efficiency Output Pressure Performance Using Capacitive Micromachined Ultrasonic Transducers with Substrate-Embedded Springs.
    Lee BC; Nikoozadeh A; Park KK; Khuri-Yakub BT
    Sensors (Basel); 2018 Aug; 18(8):. PubMed ID: 30072601
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Stepped-plate ultrasonic transducer used as a source of harmonic radiation force optimized by genetic algorithm.
    Selicani GV; Buiochi F
    Ultrasonics; 2021 Sep; 116():106505. PubMed ID: 34217912
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A negative-capacitance equivalent circuit model for parallel-plate capacitive-gap-transduced micromechanical resonators.
    Akgul M; Wu L; Ren Z; Nguyen CT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 May; 61(5):849-69. PubMed ID: 24801124
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Nonlinear modeling of an immersed transmitting capacitive micromachined ultrasonic transducer for harmonic balance analysis.
    Oguz HK; Olcum S; Senlik MN; Taş V; Atalar A; Köymen H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010; 57(2):438-47. PubMed ID: 20178910
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Finite-element analysis of capacitive micromachined ultrasonic transducers.
    Yaralioglu GG; Ergun AS; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2185-98. PubMed ID: 16463485
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Acoustic reflectivity minimization in Capacitive Micromachined Ultrasonic Transducers (CMUTs).
    La Mura M; Lamberti NA; Mauti BL; Caliano G; Savoia AS
    Ultrasonics; 2017 Jan; 73():130-139. PubMed ID: 27643654
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Simulation and experimental characterization of a 2-D capacitive micromachined ultrasonic transducer array element.
    Oralkan O; Jin X; Degertekin FL; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(6):1337-40. PubMed ID: 18244328
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surface micromachined capacitive ultrasonic transducers.
    Ladabaum I; Jin X; Soh HT; Atalar A; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(3):678-90. PubMed ID: 18244219
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Therapeutic Effect Enhancement by Dual-bias High-voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications.
    Choi H; Choe SW
    Sensors (Basel); 2018 Nov; 18(12):. PubMed ID: 30513693
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Radiation impedance of an array of circular capacitive micromachined ultrasonic transducers.
    Senlik MN; Olcum S; Koymen H; Atalar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Apr; 57(4):969-76. PubMed ID: 20378459
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.