These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

243 related articles for article (PubMed ID: 28804839)

  • 21. Optical multichannel (optimul) platelet aggregometry in 96-well plates as an additional method of platelet reactivity testing.
    Chan MV; Armstrong PC; Papalia F; Kirkby NS; Warner TD
    Platelets; 2011; 22(7):485-94. PubMed ID: 21806492
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A prospective cohort study of light transmission platelet aggregometry for bleeding disorders: is testing native platelet-rich plasma non-inferior to testing platelet count adjusted samples?
    Castilloux JF; Moffat KA; Liu Y; Seecharan J; Pai M; Hayward CP
    Thromb Haemost; 2011 Oct; 106(4):675-82. PubMed ID: 21947061
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Is TRAP-6 suitable as a positive control for platelet reactivity when assessing response to clopidogrel?
    Gremmel T; Calatzis A; Steiner S; Kaider A; Seidinger D; Koppensteiner R; Kopp CW; Panzer S
    Platelets; 2010; 21(7):515-21. PubMed ID: 20624009
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Light transmission aggregometry and ATP release for the diagnostic assessment of platelet function.
    Cattaneo M
    Semin Thromb Hemost; 2009 Mar; 35(2):158-67. PubMed ID: 19408189
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Diagnosis of Glanzmann thrombasthenia by whole blood impedance analyzer (MEA) vs. light transmission aggregometry.
    Albanyan A; Al-Musa A; AlNounou R; Al Zahrani H; Nasr R; AlJefri A; Saleh M; Malik A; Masmali H; Owaidah T
    Int J Lab Hematol; 2015 Aug; 37(4):503-8. PubMed ID: 25537026
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Standardization of light transmittance aggregometry for monitoring antiplatelet therapy: an adjustment for platelet count is not necessary.
    Linnemann B; Schwonberg J; Mani H; Prochnow S; Lindhoff-Last E
    J Thromb Haemost; 2008 Apr; 6(4):677-83. PubMed ID: 18182038
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Aspirin response evaluated by the VerifyNow Aspirin System and light transmission aggregometry.
    Nielsen HL; Kristensen SD; Thygesen SS; Mortensen J; Pedersen SB; Grove EL; Hvas AM
    Thromb Res; 2008; 123(2):267-73. PubMed ID: 18499236
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A comparison of six major platelet function tests to determine the prevalence of aspirin resistance in patients with stable coronary artery disease.
    Lordkipanidzé M; Pharand C; Schampaert E; Turgeon J; Palisaitis DA; Diodati JG
    Eur Heart J; 2007 Jul; 28(14):1702-8. PubMed ID: 17569678
    [TBL] [Abstract][Full Text] [Related]  

  • 29. More on preanalytical variables affecting platelet function testing using light transmittance aggregometry.
    Favaloro EJ
    Clin Chem Lab Med; 2011 Apr; 49(4):737-9. PubMed ID: 21275810
    [No Abstract]   [Full Text] [Related]  

  • 30. Standardization of Light Transmission Aggregometry for Diagnosis of Platelet Disorders: An Inter-Laboratory External Quality Assessment.
    Althaus K; Zieger B; Bakchoul T; Jurk K;
    Thromb Haemost; 2019 Jul; 119(7):1154-1161. PubMed ID: 31154663
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Response to aspirin in healthy individuals. Cross-comparison of light transmission aggregometry, VerifyNow system, platelet count drop, thromboelastography (TEG) and urinary 11-dehydrothromboxane B(2).
    Blais N; Pharand C; Lordkipanidzé M; Sia YK; Merhi Y; Diodati JG
    Thromb Haemost; 2009 Aug; 102(2):404-11. PubMed ID: 19652893
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects of pH and concentration of sodium citrate anticoagulant on platelet aggregation measured by light transmission aggregometry induced by adenosine diphosphate.
    Germanovich K; Femia EA; Cheng CY; Dovlatova N; Cattaneo M
    Platelets; 2018 Jan; 29(1):21-26. PubMed ID: 28643541
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Validation of flow cytometric analysis of platelet function in patients with a suspected platelet function defect.
    van Asten I; Schutgens REG; Baaij M; Zandstra J; Roest M; Pasterkamp G; Huisman A; Korporaal SJA; Urbanus RT
    J Thromb Haemost; 2018 Apr; 16(4):689-698. PubMed ID: 29337406
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparative study of light transmission aggregometry and automated bedside platelet function assays in patients undergoing percutaneous coronary intervention and receiving abciximab, eptifibatide, or tirofiban.
    Simon DI; Liu CB; Ganz P; Kirshenbaum JM; Piana RN; Rogers C; Selwyn AP; Popma JJ
    Catheter Cardiovasc Interv; 2001 Apr; 52(4):425-32. PubMed ID: 11285593
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrical impedance vs. light transmission aggregometry: Testing platelet reactivity to antiplatelet drugs using the MICELI POC impedance aggregometer as compared to a commercial predecessor.
    Mencarini T; Roka-Moiia Y; Bozzi S; Redaelli A; Slepian MJ
    Thromb Res; 2021 Aug; 204():66-75. PubMed ID: 34147831
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Diagnostic utility of light transmission platelet aggregometry: results from a prospective study of individuals referred for bleeding disorder assessments.
    Hayward CP; Pai M; Liu Y; Moffat KA; Seecharan J; Webert KE; Cook RJ; Heddle NM
    J Thromb Haemost; 2009 Apr; 7(4):676-84. PubMed ID: 19143930
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Aggregometry in the settings of thrombocytopenia, thrombocytosis and antiplatelet therapy.
    Podda G; Scavone M; Femia EA; Cattaneo M
    Platelets; 2018 Nov; 29(7):644-649. PubMed ID: 29537938
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Flow cytometric analysis of platelet function to improve the recognition of thrombocytopathy.
    Huskens D; Li L; Florin L; de Kesel P; de Laat B; Roest M; Devreese KMJ
    Thromb Res; 2020 Oct; 194():183-189. PubMed ID: 32788114
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Assessment of platelet function on whole blood by multiple electrode aggregometry in high-risk patients with coronary artery disease receiving antiplatelet therapy.
    Paniccia R; Antonucci E; Maggini N; Romano E; Gori AM; Marcucci R; Prisco D; Abbate R
    Am J Clin Pathol; 2009 Jun; 131(6):834-42. PubMed ID: 19461090
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Insights into the interpretation of light transmission aggregometry for evaluation of platelet aggregation inhibition by clopidogrel.
    Lordkipanidzé M; Pharand C; Palisaitis DA; Schampaert E; Diodati JG
    Thromb Res; 2009 Nov; 124(5):546-53. PubMed ID: 19419755
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.