These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

383 related articles for article (PubMed ID: 28806566)

  • 1. Volumetric adsorptive microsampling-liquid chromatography tandem mass spectrometry assay for the simultaneous quantification of four antibiotics in human blood: Method development, validation and comparison with dried blood spot.
    Barco S; Castagnola E; Moscatelli A; Rudge J; Tripodi G; Cangemi G
    J Pharm Biomed Anal; 2017 Oct; 145():704-710. PubMed ID: 28806566
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Volumetric absorptive microsampling (VAMS) as an alternative to conventional dried blood spots in the quantification of miltefosine in dried blood samples.
    Kip AE; Kiers KC; Rosing H; Schellens JHM; Beijnen JH; Dorlo TPC
    J Pharm Biomed Anal; 2017 Feb; 135():160-166. PubMed ID: 28033553
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC-MS/MS using a novel atmospheric pressure ionization probe (UniSpray™).
    Paniagua-González L; Díaz-Louzao C; Lendoiro E; Otero-Antón E; Cadarso-Suárez C; López-Rivadulla M; Cruz A; de-Castro-Ríos A
    J Pharm Biomed Anal; 2020 Sep; 189():113422. PubMed ID: 32590273
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.
    De Kesel PM; Lambert WE; Stove CP
    Anal Chim Acta; 2015 Jun; 881():65-73. PubMed ID: 26041521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Drug monitoring by volumetric absorptive microsampling: method development considerations to mitigate hematocrit effects.
    Fang K; Bowen CL; Kellie JF; Karlinsey MZ; Evans CA
    Bioanalysis; 2018 Feb; 10(4):241-255. PubMed ID: 29333871
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients.
    Qu Y; Brady K; Apilado R; O'Malley T; Reddy S; Chitkara P; Ibarra C; Alexander RV; Dervieux T
    J Pharm Biomed Anal; 2017 Jun; 140():334-341. PubMed ID: 28391006
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples.
    Rajadhyaksha M; Londhe V
    J Chromatogr B Analyt Technol Biomed Life Sci; 2024 Aug; 1244():124255. PubMed ID: 39059319
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Volumetric absorptive microsampling as an alternative sampling strategy for the determination of paracetamol in blood and cerebrospinal fluid.
    Delahaye L; Dhont E; De Cock P; De Paepe P; Stove CP
    Anal Bioanal Chem; 2019 Jan; 411(1):181-191. PubMed ID: 30353218
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Volumetric absorptive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs.
    Velghe S; Stove CP
    Anal Bioanal Chem; 2018 Mar; 410(9):2331-2341. PubMed ID: 29362853
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation and clinical application of an LC-MS/MS method for the quantification of everolimus using volumetric absorptive microsampling.
    Verheijen RB; Thijssen B; Atrafi F; Schellens JHM; Rosing H; de Vries N; Beijnen JH; Mathijssen RHJ; Steeghs N; Huitema ADR
    J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Jan; 1104():234-239. PubMed ID: 30530116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Volumetric absorptive microsampling for the quantification of tacrolimus in capillary blood by high performance liquid chromatography-tandem mass spectrometry.
    Tron C; Ferrand-Sorre MJ; Querzerho-Raguideau J; Chemouny JM; Houssel-Debry P; Verdier MC; Bellissant E; Lemaitre F
    J Chromatogr B Analyt Technol Biomed Life Sci; 2021 Feb; 1165():122521. PubMed ID: 33486216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Volumetric absorptive microsampling (VAMS®) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development.
    Gao X; Chen C; Geng D; Bateman KP; Shi S; Woolf EJ; Xu Y
    J Pharm Biomed Anal; 2021 Mar; 196():113895. PubMed ID: 33486450
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics.
    Jacobs CM; Wagmann L; Meyer MR
    Anal Bioanal Chem; 2021 Mar; 413(6):1729-1737. PubMed ID: 33517479
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitation of meropenem in dried blood spots using microfluidic-based volumetric sampling coupled with LC-MS/MS bioanalysis in preterm neonates.
    Hu L; Zhang J; He J; Zhang S; Liu D; Shao H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2023 Feb; 1217():123625. PubMed ID: 36753842
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A liquid chromatography-tandem mass spectrometry platform for the routine therapeutic drug monitoring of 14 antibiotics: Application to critically ill pediatric patients.
    Barco S; Mesini A; Barbagallo L; Maffia A; Tripodi G; Pea F; Saffioti C; Castagnola E; Cangemi G
    J Pharm Biomed Anal; 2020 Jul; 186():113273. PubMed ID: 32251979
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Volumetric absorptive microsampling (VAMS) for the quantification of ten kinase inhibitors and determination of their in vitro VAMS-to-plasma ratio.
    Zimmermann S; Aghai F; Schilling B; Kraus S; Grigoleit GU; Kalogirou C; Goebeler ME; Jung P; Pelzer T; Klinker H; Isberner N; Scherf-Clavel O
    J Pharm Biomed Anal; 2022 Mar; 211():114623. PubMed ID: 35121279
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Volumetric absorptive microsampling as an effective microsampling technique for LC-MS/MS bioanalysis of biomarkers in drug discovery.
    Kapadnis U; Locuson C; Okamura H; Rienzo G; Cotter C; Zhu D; Narayanaswami R; Castro-Perez J; Marathe P; Yang WC
    Bioanalysis; 2023 Jul; 15(14):845-859. PubMed ID: 37305945
    [No Abstract]   [Full Text] [Related]  

  • 18. Volumetric absorptive microsampling as a suitable tool to monitor tyrosine kinase inhibitors.
    Verougstraete N; Stove CP
    J Pharm Biomed Anal; 2022 Jan; 207():114418. PubMed ID: 34655987
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.
    Protti M; Rudge J; Sberna AE; Gerra G; Mercolini L
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Feb; 1044-1045():77-86. PubMed ID: 28088044
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analytical and clinical validation of dried blood spot and volumetric absorptive microsampling for measurement of tacrolimus and creatinine after renal transplantation.
    Mathew BS; Mathew SK; Aruldhas BW; Prabha R; Gangadharan N; David VG; Varughese S; John GT
    Clin Biochem; 2022; 105-106():25-34. PubMed ID: 35490728
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.