131 related articles for article (PubMed ID: 28829010)
1. Combined Stump Pressure and Oximetry for Shunt Use During Carotid Endarterectomy.
Findlay JM; Kesarwani R; Jacka M; Marchak BE
Can J Neurol Sci; 2017 Nov; 44(6):692-696. PubMed ID: 28829010
[TBL] [Abstract][Full Text] [Related]
2. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy.
Lee TS; Hines GL; Feuerman M
Ann Vasc Surg; 2008 Jan; 22(1):58-62. PubMed ID: 18023554
[TBL] [Abstract][Full Text] [Related]
3. Cerebral monitoring during carotid endarterectomy--a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure.
Botes K; Le Roux DA; Van Marle J
S Afr J Surg; 2007 May; 45(2):43-6. PubMed ID: 17674560
[TBL] [Abstract][Full Text] [Related]
4. Near-infrared spectroscopy as a predictor of cerebral ischaemia during carotid endarterectomy in awake patients.
Inčiūra D; Antuševas A; Aladaitis A; Gimžauskaitė A; Velička L; Kavaliauskienė Ž
Vascular; 2020 Jun; 28(3):301-308. PubMed ID: 31937208
[TBL] [Abstract][Full Text] [Related]
5. Correlation of cerebral oximetry with internal carotid artery stump pressures in carotid endarterectomy.
Manwaring ML; Durham CA; McNally MM; Agle SC; Parker FM; Stoner MC
Vasc Endovascular Surg; 2010 May; 44(4):252-6. PubMed ID: 20356866
[TBL] [Abstract][Full Text] [Related]
6. Angiographic criteria reliably predict when carotid endarterectomy can be safely performed without a shunt.
Wain RA; Veith FJ; Berkowitz BA; Legatt AD; Schwartz M; Lipsitz EC; Haut SR; Bello JA
J Am Coll Surg; 1999 Jul; 189(1):93-100; discussion 100-1. PubMed ID: 10401745
[TBL] [Abstract][Full Text] [Related]
7. The sensibility and specificity of cerebral oximetry, measured by INVOS - 4100, in patients undergoing carotid endarterectomy compared with awake testing.
Stilo F; Spinelli F; Martelli E; Pipitó N; Barillà D; De Caridi G; Benedetto F; Risitano D; Noto A; Messina R; David A
Minerva Anestesiol; 2012 Oct; 78(10):1126-35. PubMed ID: 23059517
[TBL] [Abstract][Full Text] [Related]
8. Carotid Artery Stump Pressure (CASP) in 1135 consecutive endarterectomies under general anesthesia: an old method that survived the test of times.
Jacob T; Hingorani A; Ascher E
J Cardiovasc Surg (Torino); 2007 Dec; 48(6):677-81. PubMed ID: 17947923
[TBL] [Abstract][Full Text] [Related]
9. Near Infrared Spectroscopy as a Predictor for Shunt Requirement During Carotid Endarterectomy.
Jonsson M; Lindström D; Wanhainen A; Djavani Gidlund K; Gillgren P
Eur J Vasc Endovasc Surg; 2017 Jun; 53(6):783-791. PubMed ID: 28431821
[TBL] [Abstract][Full Text] [Related]
10. Prospective randomized trial of routine versus selective shunting in carotid endarterectomy based on stump pressure.
Aburahma AF; Stone PA; Hass SM; Dean LS; Habib J; Keiffer T; Emmett M
J Vasc Surg; 2010 May; 51(5):1133-8. PubMed ID: 20347544
[TBL] [Abstract][Full Text] [Related]
11. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping.
Yamamoto K; Miyata T; Nagawa H
Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209
[TBL] [Abstract][Full Text] [Related]
12. Cerebral oximetry does not correlate with electroencephalography and somatosensory evoked potentials in determining the need for shunting during carotid endarterectomy.
Friedell ML; Clark JM; Graham DA; Isley MR; Zhang XF
J Vasc Surg; 2008 Sep; 48(3):601-6. PubMed ID: 18639412
[TBL] [Abstract][Full Text] [Related]
13. Carotid endarterectomy: a new technique replacing internal shunts.
Fachinetti P; Bellocchi S; Ramponi G; Sardella M; Dorizzi A
Acta Neurochir (Wien); 2001; 143(5):457-63; discussion 463-4. PubMed ID: 11482695
[TBL] [Abstract][Full Text] [Related]
14. Cerebral oximetry for the detection of cerebral ischemia during temporary carotid artery occlusion.
Takeda N; Fujita K; Katayama S; Tamaki N
Neurol Med Chir (Tokyo); 2000 Nov; 40(11):557-62; discussion 562-3. PubMed ID: 11109792
[TBL] [Abstract][Full Text] [Related]
15. Clinical validation of 40-mmHg carotid stump pressure for patients undergoing carotid endarterectomy under general anesthesia.
Shahidi S; Owen-Falkenberg A; Gottschalksen B
J Cardiovasc Surg (Torino); 2017 Jun; 58(3):431-438. PubMed ID: 24918194
[TBL] [Abstract][Full Text] [Related]
16. Computerized electroencephalographic monitoring and selective shunting: influence on intraoperative administration of phenylephrine and myocardial infarction after general anesthesia for carotid endarterectomy.
Modica PA; Tempelhoff R; Rich KM; Grubb RL
Neurosurgery; 1992 Jun; 30(6):842-6. PubMed ID: 1614584
[TBL] [Abstract][Full Text] [Related]
17. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy.
Pennekamp CW; Immink RV; den Ruijter HM; Kappelle LJ; Bots ML; Buhre WF; Moll FL; de Borst GJ
Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):397-403. PubMed ID: 23973277
[TBL] [Abstract][Full Text] [Related]
18. Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients.
Hans SS; Jareunpoon O
J Vasc Surg; 2007 Mar; 45(3):511-5. PubMed ID: 17275248
[TBL] [Abstract][Full Text] [Related]
19. Correlation of intraoperative collateral perfusion pressure during carotid endarterectomy and status of the contralateral carotid artery and collateral cerebral blood flow.
AbuRahma AF; Mousa AY; Stone PA; Hass SM; Dean LS; Keiffer T
Ann Vasc Surg; 2011 Aug; 25(6):830-6. PubMed ID: 21680143
[TBL] [Abstract][Full Text] [Related]
20. Cerebral Neuromonitoring during Carotid Endarterectomy and Impact of Contralateral Internal Carotid Occlusion.
Sef D; Skopljanac-Macina A; Milosevic M; Skrtic A; Vidjak V
J Stroke Cerebrovasc Dis; 2018 May; 27(5):1395-1402. PubMed ID: 29397311
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]