These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

293 related articles for article (PubMed ID: 28830928)

  • 21. A new technique for two-hand bag valve mask ventilation.
    Thomas AN; Dang PT; Hyatt J; Trinh TN
    Br J Anaesth; 1992 Oct; 69(4):397-8. PubMed ID: 1419449
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An evaluation of peak inspiratory pressure, tidal volume, and ventilatory frequency during ventilation with a neonatal self-inflating bag resuscitator.
    Bassani MA; Filho FM; de Carvalho Coppo MR; Martins Marba ST
    Respir Care; 2012 Apr; 57(4):525-30. PubMed ID: 22005778
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin.
    Solevåg AL; Haemmerle E; van Os S; Bach KP; Cheung PY; Schmölzer GM
    Front Pediatr; 2016; 4():129. PubMed ID: 27965949
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of three methods of bag valve mask ventilation.
    Wheatley S; Thomas AN; Taylor RJ; Brown T
    Resuscitation; 1997 Jan; 33(3):207-10. PubMed ID: 9044491
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Use of neonatal simulation models to assess competency in bag-mask ventilation.
    Pearlman SA; Zern SC; Blackson T; Ciarlo JA; Mackley AB; Locke RG
    J Perinatol; 2016 Mar; 36(3):242-6. PubMed ID: 26583941
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag.
    Barnes TA; Catino ME; Burns EC; Chan WK; Ghazarian G; Henneberg WR; Ruel KE; Stanley SA
    Respir Care; 2005 Nov; 50(11):1445-50. PubMed ID: 16253151
    [TBL] [Abstract][Full Text] [Related]  

  • 27. T-piece versus self-inflating bag ventilation in preterm neonates at birth.
    Guinsburg R; de Almeida MFB; de Castro JS; Gonçalves-Ferri WA; Marques PF; Caldas JPS; Krebs VLJ; Souza Rugolo LMS; de Almeida JHCL; Luz JH; Procianoy RS; Duarte JLMB; Penido MG; Ferreira DMLM; Alves Filho N; Diniz EMA; Santos JP; Acquesta AL; Santos CND; Gonzalez MRC; da Silva RPVC; Meneses J; Lopes JMA; Martinez FE
    Arch Dis Child Fetal Neonatal Ed; 2018 Jan; 103(1):F49-F55. PubMed ID: 28663283
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The mouth-to-bag resuscitator during standard anaesthesia induction in apnoeic patients.
    Herff H; Paal P; Mitterlechner T; von Goedecke A; Stadlbauer KH; Voelckel WG; Zecha-Stallinger A; Wenzel V
    Resuscitation; 2009 Oct; 80(10):1142-6. PubMed ID: 19674827
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Can Ambu self-inflating bag and Neopuff infant resuscitator provide adequate and safe manual inflations for infants up to 10 kg weight?
    Tracy M; Maheshwari R; Shah D; Hinder M
    Arch Dis Child Fetal Neonatal Ed; 2017 Jul; 102(4):F333-F338. PubMed ID: 28011794
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Responding to compliance changes in a lung model during manual ventilation: perhaps volume, rather than pressure, should be displayed.
    Kattwinkel J; Stewart C; Walsh B; Gurka M; Paget-Brown A
    Pediatrics; 2009 Mar; 123(3):e465-70. PubMed ID: 19188267
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?
    Maheshwari R; Tracy M; Hinder M; Wright A
    J Paediatr Child Health; 2017 Aug; 53(8):761-765. PubMed ID: 28675548
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of a novel paediatric self-inflating bag to improve accuracy of tidal volumes delivered during simulated advanced paediatric resuscitation.
    Park SO; Lee KR; Baek KJ; Shim HW; Hong DY
    Resuscitation; 2012 Jan; 83(1):101-6. PubMed ID: 21864479
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.
    O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F392-6. PubMed ID: 15871989
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Neonatal ventilation with a manikin model and two novel PEEP valves without an external gas source.
    Thallinger M; Ersdal HL; Morley C; Purington C; Gomo Ø; Mduma E; Eilevstjønn J; Størdal K
    Arch Dis Child Fetal Neonatal Ed; 2017 May; 102(3):F208-F213. PubMed ID: 27573519
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Device capable of reducing gastric inflation during artificial ventilation in a manikin model.
    Mutzbauer T; Tabacek G
    J Emerg Med; 2010 May; 38(4):428-33. PubMed ID: 18486408
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Providing PEEP during neonatal resuscitation: which device is best?
    Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
    J Paediatr Child Health; 2011 Oct; 47(10):698-703. PubMed ID: 21449898
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Developing a strategy to improve ventilation in an unprotected airway with a modified mouth-to-bag resuscitator in apneic patients.
    von Goedecke A; Keller C; Wagner-Berger HG; Voelckel WG; Hörmann C; Zecha-Stallinger A; Wenzel V
    Anesth Analg; 2004 Nov; 99(5):1516-1520. PubMed ID: 15502057
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of positive pressure ventilation devices in a newborn manikin.
    Solevåg AL; Haemmerle E; van Os S; Bach KP; Cheung PY; Schmölzer GM
    J Matern Fetal Neonatal Med; 2017 Mar; 30(5):595-599. PubMed ID: 27090159
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Newborn self-inflating manual resuscitators: precision robotic testing of safety and reliability.
    Tracy MB; Halliday R; Tracy SK; Hinder MK
    Arch Dis Child Fetal Neonatal Ed; 2019 Jul; 104(4):F403-F408. PubMed ID: 30337333
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Newborn ventilation: comparison between a T-piece resuscitator and self-infating bags in a neonatal preterm simulator].
    Szyld EG; Aguilar AM; Musante GA; Vain NE; Guerrero MN; Serra ME; Prudent LM; Carlo WA
    Arch Argent Pediatr; 2012 Apr; 110(2):106-12. PubMed ID: 22451282
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.