These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
512 related articles for article (PubMed ID: 28841999)
1. Voltammetric detection of carbofuran determination using screen-printed carbon electrodes modified with gold nanoparticles and graphene oxide. Jirasirichote A; Punrat E; Suea-Ngam A; Chailapakul O; Chuanuwatanakul S Talanta; 2017 Dec; 175():331-337. PubMed ID: 28841999 [TBL] [Abstract][Full Text] [Related]
2. A highly sensitive electrochemical sensor based on poly(3-aminobenzoic acid)/graphene oxide-gold nanoparticles modified screen printed carbon electrode for paraquat detection. Pimalai D; Putnin T; Bamrungsap S J Environ Sci (China); 2025 Feb; 148():139-150. PubMed ID: 39095153 [TBL] [Abstract][Full Text] [Related]
3. Investigate electrochemical immunosensor of cortisol based on gold nanoparticles/magnetic functionalized reduced graphene oxide. Sun B; Gou Y; Ma Y; Zheng X; Bai R; Ahmed Abdelmoaty AA; Hu F Biosens Bioelectron; 2017 Feb; 88():55-62. PubMed ID: 27499382 [TBL] [Abstract][Full Text] [Related]
5. Fabrication of graphene/gold-modified screen-printed electrode for detection of carcinoembryonic antigen. Chan KF; Lim HN; Shams N; Jayabal S; Pandikumar A; Huang NM Mater Sci Eng C Mater Biol Appl; 2016 Jan; 58():666-74. PubMed ID: 26478358 [TBL] [Abstract][Full Text] [Related]
6. Very sensitive electrochemical determination of diuron on glassy carbon electrode modified with reduced graphene oxide-gold nanoparticle-Nafion composite film. Zarei K; Khodadadi A Ecotoxicol Environ Saf; 2017 Oct; 144():171-177. PubMed ID: 28622555 [TBL] [Abstract][Full Text] [Related]
7. Electroanalytical Determination of Ziram by Differential Pulse Voltammetry with Reduced Graphene Oxide/Gold Nanoparticles Modified Glassy Carbon Electrode. Aslan N; Ocak SB; Gökmen U Acta Chim Slov; 2022 Sep; 69(3):638-646. PubMed ID: 36196823 [TBL] [Abstract][Full Text] [Related]
8. A highly sensitive competitive immunosensor based on branched polyethyleneimine functionalized reduced graphene oxide and gold nanoparticles modified electrode for detection of melamine. Ren Q; Shen X; Sun Y; Fan R; Zhang J Food Chem; 2020 Jan; 304():125397. PubMed ID: 31479996 [TBL] [Abstract][Full Text] [Related]
9. Functionalized gold nanoparticles/reduced graphene oxide nanocomposites for ultrasensitive electrochemical sensing of mercury ions based on thymine-mercury-thymine structure. Wang N; Lin M; Dai H; Ma H Biosens Bioelectron; 2016 May; 79():320-6. PubMed ID: 26720921 [TBL] [Abstract][Full Text] [Related]
10. Glucose oxidase immobilized amine terminated multiwall carbon nanotubes/reduced graphene oxide/polyaniline/gold nanoparticles modified screen-printed carbon electrode for highly sensitive amperometric glucose detection. Maity D; C R M; R T RK Mater Sci Eng C Mater Biol Appl; 2019 Dec; 105():110075. PubMed ID: 31546385 [TBL] [Abstract][Full Text] [Related]
11. Sonochemical and sustainable synthesis of graphene-gold (G-Au) nanocomposites for enzymeless and selective electrochemical detection of nitric oxide. Geetha Bai R; Muthoosamy K; Zhou M; Ashokkumar M; Huang NM; Manickam S Biosens Bioelectron; 2017 Jan; 87():622-629. PubMed ID: 27616288 [TBL] [Abstract][Full Text] [Related]
12. Highly sensitive and selective detection of dopamine based on hollow gold nanoparticles-graphene nanocomposite modified electrode. Zhu W; Chen T; Ma X; Ma H; Chen S Colloids Surf B Biointerfaces; 2013 Nov; 111():321-6. PubMed ID: 23838199 [TBL] [Abstract][Full Text] [Related]
13. Preparation and characterization of AuNPs/CNTs-ErGO electrochemical sensors for highly sensitive detection of hydrazine. Zhao Z; Sun Y; Li P; Zhang W; Lian K; Hu J; Chen Y Talanta; 2016 Sep; 158():283-291. PubMed ID: 27343607 [TBL] [Abstract][Full Text] [Related]
14. Gold nanoparticles conjugates-amplified aptamer immunosensing screen-printed carbon electrode strips for thrombin detection. Yeh FY; Liu TY; Tseng IH; Yang CW; Lu LC; Lin CS Biosens Bioelectron; 2014 Nov; 61():336-43. PubMed ID: 24912033 [TBL] [Abstract][Full Text] [Related]
15. Electrochemical Determination of Chlorogenic Acid in Nutraceuticals Using Voltammetric Sensors Based on Screen-Printed Carbon Electrode Modified with Graphene and Gold Nanoparticles. Munteanu IG; Apetrei C Int J Mol Sci; 2021 Aug; 22(16):. PubMed ID: 34445600 [TBL] [Abstract][Full Text] [Related]
17. Determination of the antioxidant propyl gallate in meat by using a screen-printed electrode modified with CoSe Chen SM; Manavalan S; Rajaji U; Govindasamy M; Chen TW; Ajmal Ali M; Alnakhli AK; Al-Hemaid FMA; Elshikh MS Mikrochim Acta; 2018 Oct; 185(11):520. PubMed ID: 30367266 [TBL] [Abstract][Full Text] [Related]
18. Supramolecular Electrochemical Sensor for Dopamine Detection Based on Self-Assembled Mixed Surfactants on Gold Nanoparticles Deposited Graphene Oxide. Uppachai P; Srijaranai S; Poosittisak S; Md Isa I; Mukdasai S Molecules; 2020 May; 25(11):. PubMed ID: 32485804 [TBL] [Abstract][Full Text] [Related]
19. An Electrochemical Screen-Printed Sensor Based on Gold-Nanoparticle-Decorated Reduced Graphene Oxide-Carbon Nanotubes Composites for the Determination of 17-β Estradiol. Musa AM; Kiely J; Luxton R; Honeychurch KC Biosensors (Basel); 2023 Apr; 13(4):. PubMed ID: 37185565 [TBL] [Abstract][Full Text] [Related]
20. An enzymeless organophosphate pesticide sensor using Au nanoparticle-decorated graphene hybrid nanosheet as solid-phase extraction. Gong J; Miao X; Zhou T; Zhang L Talanta; 2011 Sep; 85(3):1344-9. PubMed ID: 21807193 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]