These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

265 related articles for article (PubMed ID: 28843787)

  • 21. Evaluation of a rapid test for the detection of antibodies to human immunodeficiency virus type 1 and 2 in the setting of multiple transmitted viral subtypes.
    Reynolds SJ; Ndongala LM; Luo CC; Mwandagalirwa K; Losoma AJ; Mwamba KJ; Bazepeyo E; Nzilambi NE; Quinn TC; Bollinger RC
    Int J STD AIDS; 2002 Mar; 13(3):171-3. PubMed ID: 11860693
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of rapid HIV-1/HIV-2 INSTI on plasma and capillary blood for serological diagnosis of non B subtypes and circulating recombinant forms of HIV-1 in Gabon.
    Ndjoyi-Mbiguino A; Nzengui Nzengui GF; Robin L; M'Boyis Kamdem H; Bélec L
    Med Mal Infect; 2015 Aug; 45(8):339-40. PubMed ID: 26159380
    [No Abstract]   [Full Text] [Related]  

  • 23. Field Evaluation of a Dual Rapid Immunodiagnostic Test for HIV and Syphilis Infection in Peru.
    Bristow CC; Leon SR; Huang E; Ramos LB; Vargas SK; Flores JA; Konda KA; Caceres CF; Klausner JD
    Sex Transm Dis; 2016 Jan; 43(1):57-60. PubMed ID: 26650998
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparative performance of electrochemiluminescence immunoassay and EIA for HIV screening in a multiethnic region of China.
    Bi X; Ning H; Wang T; Li D; Liu Y; Yang T; Yu J; Tao C
    PLoS One; 2012; 7(10):e48162. PubMed ID: 23144740
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting.
    Ingole NA; Mehta PR; Bande RN; Paranjpe SM; Wanjare SW
    Indian J Med Microbiol; 2010; 28(4):295-8. PubMed ID: 20966557
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Performance evaluation of a particle agglutination test for antibody to human immunodeficiency virus 1: comparison with enzyme immunoassay.
    Elavia AJ; Thomas A; Nandi J; Coyaji GD; Bhavalkar-Potdar V
    Vox Sang; 1995; 69(1):23-6. PubMed ID: 7483488
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Specificity of new peptide immunoassays versus other immunoassays and agglutination tests for detection of HIV antibody in African sera.
    Léonard G; Verdier M; Sangaré A; Rey JL; Denis F
    Eur J Clin Microbiol Infect Dis; 1991 Aug; 10(8):636-40. PubMed ID: 1660808
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sensitivity of the STAT-VIEW rapid self-test and implications for use during acute HIV infection.
    Boukli N; Boyd A; Wendremaire N; Girard PM; Bottero J; Morand-Joubert L
    Sex Transm Infect; 2018 Nov; 94(7):475-478. PubMed ID: 28835532
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Use of stored serum from Uganda for development and evaluation of a human immunodeficiency virus type 1 testing algorithm involving multiple rapid immunoassays.
    Singer DE; Kiwanuka N; Serwadda D; Nalugoda F; Hird L; Bulken-Hoover J; Kigozi G; Malia JA; Calero EK; Sateren W; Robb ML; Wabwire-Mangen F; Wawer M; Gray RH; Sewankambo N; Birx DL; Michael NL
    J Clin Microbiol; 2005 Oct; 43(10):5312-5. PubMed ID: 16208006
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [The capacities of current test systems to verify early HIV infection].
    Baranova EN; Sharipova IN; Denisova NM; Susekina ME; Puzyrev VF; Sarkisian KA; Vorob'eva MS; Burkov AN; Ulanova TI
    Vopr Virusol; 2009; 54(5):37-40. PubMed ID: 19882902
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Differentiation of human immunodeficiency virus type 1 (HIV-1) infections with HIV-2-cross-reacting antibody from mixed infections with HIV-1 and HIV-2 by serological absorption test.
    Imai M; Hayashi T; Kondo M; Saito T; Ito A; Hayami M; Nishioka K
    J Clin Microbiol; 1995 Jul; 33(7):1727-9. PubMed ID: 7665636
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Performance characteristics of a rapid new immunochromatographic test for detection of antibodies to human immunodeficiency virus.
    Ribeiro-Rodrigues R; Ferreira da Silva Pinto Neto L; Cunha CB; Cabral VP; Dietze R
    Clin Diagn Lab Immunol; 2003 Mar; 10(2):303-7. PubMed ID: 12626458
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Immunofluorescence assay in India for confirmation of HIV-1 infection using a T-cell line infected with defective HIV-1.
    Bala M; Arias JF; Deb M; Ikuta K
    Int J Infect Dis; 2010 Dec; 14(12):e1093-8. PubMed ID: 20952236
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Performance evaluation of the ADVIA Centaur(®) HIV Ag/Ab Combo assay.
    Pumarola T; Freeman J; Saxton E; Dillon P; Bal T; van Helden J
    J Virol Methods; 2010 Dec; 170(1-2):16-20. PubMed ID: 20723562
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Analysis of False-Negative Human Immunodeficiency Virus Rapid Tests Performed on Oral Fluid in 3 International Clinical Research Studies.
    Curlin ME; Gvetadze R; Leelawiwat W; Martin M; Rose C; Niska RW; Segolodi TM; Choopanya K; Tongtoyai J; Holtz TH; Samandari T; McNicholl JM;
    Clin Infect Dis; 2017 Jun; 64(12):1663-1669. PubMed ID: 28369309
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An evaluation of the performance of OraQuick ADVANCE Rapid HIV-1/2 Test in a high-risk population attending genitourinary medicine clinics in East London, UK.
    Zelin J; Garrett N; Saunders J; Warburton F; Anderson J; Moir K; Symonds M; Estcourt C;
    Int J STD AIDS; 2008 Oct; 19(10):665-7. PubMed ID: 18824617
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Performance and usability evaluation of the INSTI HIV self-test in Kenya for qualitative detection of antibodies to HIV.
    Bwana P; Ochieng' L; Mwau M
    PLoS One; 2018; 13(9):e0202491. PubMed ID: 30212525
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of salivary and serum antibody detection in HIV-1 infection by ELISA and rapid methods in India.
    Garg N; Gautam V; Gill PS; Arora B; Arora DR
    Trop Doct; 2006 Apr; 36(2):108-9. PubMed ID: 16611447
    [No Abstract]   [Full Text] [Related]  

  • 39. Diagnostic particle agglutination using ultrasound: a new technology to rejuvenate old microbiological methods.
    Ellis RW; Sobanski MA
    J Med Microbiol; 2000 Oct; 49(10):853-859. PubMed ID: 11023182
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance of an oral fluid rapid HIV-1/2 test: experience from four CDC studies.
    Delaney KP; Branson BM; Uniyal A; Kerndt PR; Keenan PA; Jafa K; Gardner AD; Jamieson DJ; Bulterys M
    AIDS; 2006 Aug; 20(12):1655-60. PubMed ID: 16868447
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.