  • 1. A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent.
    Beigzadeh B; Mirmohammadi SA; Ayatollahi MR
    Biomed Mater Eng; 2017; 28(5):463-476. PubMed ID: 28854490
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Finite element analysis and stent design: Reduction of dogboning.
    De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P
    Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery--finite element simulation.
    Schiavone A; Zhao LG; Abdel-Wahab AA
    Mater Sci Eng C Mater Biol Appl; 2014 Sep; 42():479-88. PubMed ID: 25063145
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design optimization of stent and its dilatation balloon using kriging surrogate model.
    Li H; Liu T; Wang M; Zhao D; Qiao A; Wang X; Gu J; Li Z; Zhu B
    Biomed Eng Online; 2017 Jan; 16(1):13. PubMed ID: 28086895
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Computational Study of Mechanical Performance of Bioresorbable Polymeric Stents with Design Variations.
    Qiu TY; Zhao LG; Song M
    Cardiovasc Eng Technol; 2019 Mar; 10(1):46-60. PubMed ID: 30536211
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A method for investigating the mechanical properties of intracoronary stents using finite element numerical simulation.
    Tan LB; Webb DC; Kormi K; Al-Hassani ST
    Int J Cardiol; 2001 Mar; 78(1):51-67. PubMed ID: 11259813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Finite element methods to analyze helical stent expansion.
    Paryab N; Cronin DS; Lee-Sullivan P
    Int J Numer Method Biomed Eng; 2014 Mar; 30(3):339-52. PubMed ID: 24123985
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A numerical study on the application of the functionally graded materials in the stent design.
    Khosravi A; Bahreinizad H; Bani MS; Karimi A
    Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():182-188. PubMed ID: 28183596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element evaluation of artery damage in deployment of polymeric stent with pre- and post-dilation.
    He R; Zhao LG; Silberschmidt VV; Liu Y; Vogt F
    Biomech Model Mechanobiol; 2020 Feb; 19(1):47-60. PubMed ID: 31317295
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of the stent expansion in a stenosed artery using finite element method: application to stent versus stent study.
    Imani SM; Goudarzi AM; Ghasemi SE; Kalani A; Mahdinejad J
    Proc Inst Mech Eng H; 2014 Oct; 228(10):996-1004. PubMed ID: 25406228
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling of stents exhibiting negative Poisson's ratio effect.
    Raamachandran J; Jayavenkateshwaran K
    Comput Methods Biomech Biomed Engin; 2007 Aug; 10(4):245-55. PubMed ID: 17671858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Vulnerability analysis on the interaction between Asymmetric stent and arterial layer.
    Syaifudin A; Ariatedja JB; Kaelani Y; Takeda R; Sasaki K
    Biomed Mater Eng; 2019; 30(3):309-322. PubMed ID: 31127751
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of stent design parameters on normal artery wall mechanics.
    Bedoya J; Meyer CA; Timmins LH; Moreno MR; Moore JE
    J Biomech Eng; 2006 Oct; 128(5):757-65. PubMed ID: 16995763
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion.
    Lim D; Cho SK; Park WP; Kristensson A; Ko JY; Al-Hassani ST; Kim HS
    Ann Biomed Eng; 2008 Jul; 36(7):1118-29. PubMed ID: 18437572
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics.
    Timmins LH; Meyer CA; Moreno MR; Moore JE
    J Endovasc Ther; 2008 Dec; 15(6):643-54. PubMed ID: 19090628
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Numerical investigations of the mechanical properties of braided vascular stents.
    Fu W; Xia Q; Yan R; Qiao A
    Biomed Mater Eng; 2018; 29(1):81-94. PubMed ID: 29254075
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of asymmetric stent for treatment of eccentric plaque.
    Syaifudin A; Takeda R; Sasaki K
    Biomed Mater Eng; 2018; 29(3):299-317. PubMed ID: 29578470
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of carotid stent cell design on vessel scaffolding: a case study comparing experimental investigation and numerical simulations.
    Conti M; Van Loo D; Auricchio F; De Beule M; De Santis G; Verhegghe B; Pirrelli S; Odero A
    J Endovasc Ther; 2011 Jun; 18(3):397-406. PubMed ID: 21679082
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent.
    García A; Peña E; Martínez MA
    J Mech Behav Biomed Mater; 2012 Jun; 10():166-75. PubMed ID: 22520428
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiovascular stent design and vessel stresses: a finite element analysis.
    Lally C; Dolan F; Prendergast PJ
    J Biomech; 2005 Aug; 38(8):1574-81. PubMed ID: 15958213
    [TBL] [Abstract][Full Text] [Related]  