These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
152 related articles for article (PubMed ID: 28856207)
1. A new sensitive automated assay for procalcitonin detection: LIAISON Fortunato A Pract Lab Med; 2016 Dec; 6():1-7. PubMed ID: 28856207 [TBL] [Abstract][Full Text] [Related]
2. Comparison of Procalcitonin Assays on KRYPTOR and LIAISON Dipalo M; Gnocchi C; Avanzini P; Musa R; Di Pietro M; Aloe R Diagnostics (Basel); 2019 Aug; 9(3):. PubMed ID: 31398868 [TBL] [Abstract][Full Text] [Related]
3. Multicenter comparison of automated procalcitonin immunoassays. Dipalo M; Guido L; Micca G; Pittalis S; Locatelli M; Motta A; Bianchi V; Callegari T; Aloe R; Da Rin G; Lippi G Pract Lab Med; 2015 Aug; 2():22-28. PubMed ID: 28932801 [TBL] [Abstract][Full Text] [Related]
4. Comparison of the novel ARCHITECT procalcitonin assay with established procalcitonin assay systems. Soh A; Binder L; Clough M; Hernandez MH; Lefèvre G; Mostert K; Nguyen TB; Otte KM; Portakal O; Sandri MS; Yen JL; Huang J; Beshiri A Pract Lab Med; 2018 Nov; 12():e00110. PubMed ID: 30519621 [TBL] [Abstract][Full Text] [Related]
5. Concordance of Three Automated Procalcitonin Immunoassays at Medical Decision Points. Cho HW; Kim SH; Cho Y; Jeong SH; Lee SG Ann Lab Med; 2021 Jul; 41(4):419-423. PubMed ID: 33536362 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of a fully automated procalcitonin chemiluminescence immunoassay. Hubl W; Krassler J; Zingler C; Pertschy A; Hentschel J; Gerhards-Reich C; Mack M; Demant T Clin Lab; 2003; 49(7-8):319-27. PubMed ID: 12908732 [TBL] [Abstract][Full Text] [Related]
7. Analytical Evaluation of Point-of-Care Finecare™ Procalcitonin Rapid Quantitative Test in Sepsis Population as Compared with Elecsys Mazlan MZ; Wan Azman WN; Yaacob NM; Koon TS; Yahya NK Diagnostics (Basel); 2024 May; 14(11):. PubMed ID: 38893607 [TBL] [Abstract][Full Text] [Related]
8. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay. Ruzzenente O; Salvagno GL; Gelati M; Lippi G Pract Lab Med; 2016 Dec; 6():8-13. PubMed ID: 28856208 [TBL] [Abstract][Full Text] [Related]
9. Detection of procalcitonin (PCT) in healthy controls and patients with local infection by a sensitive ILMA. Morgenthaler NG; Struck J; Fischer-Schulz C; Seidel-Mueller E; Beier W; Bergmann A Clin Lab; 2002; 48(5-6):263-70. PubMed ID: 12071576 [TBL] [Abstract][Full Text] [Related]
10. Comparison of the Siemens Atellica BRAHMS and the Abbott Architect BRAHMS Procalcitonin Assays. Walker C; Shuster A; Weber C; Gebhardt K; Scheidegger M; Swartzwelder J; Williams J; Li J Ann Clin Lab Sci; 2021 Mar; 51(2):241-244. PubMed ID: 33941564 [TBL] [Abstract][Full Text] [Related]
12. Two-center comparison of 10 fully-automated commercial procalcitonin (PCT) immunoassays. Lippi G; Salvagno GL; Gelati M; Pucci M; Lo Cascio C; Demonte D; Faggian D; Plebani M Clin Chem Lab Med; 2019 Dec; 58(1):77-84. PubMed ID: 31539351 [TBL] [Abstract][Full Text] [Related]
13. Method Verification Shows a Negative Bias between 2 Procalcitonin Methods at Medical Decision Concentrations. Gruzdys V; Cahoon K; Pearson L; Lehman CM J Appl Lab Med; 2019 Jul; 4(1):69-77. PubMed ID: 31639709 [TBL] [Abstract][Full Text] [Related]
14. Diagnostic Value of Procalcitonin in ANCA-Associated Vasculitis (AAV) to Differentiate Between Disease Activity, Infection and Drug Hypersensitivity. Herrmann K; Schinke S; Csernok E; Moosig F; Holle JU Open Rheumatol J; 2015; 9():71-6. PubMed ID: 26535070 [TBL] [Abstract][Full Text] [Related]
15. Analytical evaluation of the performances of Diazyme and BRAHMS procalcitonin applied to Roche Cobas in comparison with BRAHMS PCT-sensitive Kryptor. Ceriotti F; Marino I; Motta A; Carobene A Clin Chem Lab Med; 2017 Nov; 56(1):162-169. PubMed ID: 28809746 [TBL] [Abstract][Full Text] [Related]
16. Comparison of a novel automated DiaSys procalcitonin immunoassay with four different BRAHMS-partnered immunoassays. Eidizadeh A; Wiederhold M; Schnelle M; Binder L Pract Lab Med; 2022 May; 30():e00274. PubMed ID: 35465623 [TBL] [Abstract][Full Text] [Related]
17. [Evaluation of procalcitonin assay on the Abbott Architect i2000 SR® analyzer]. El Mouatani A; Rotaru I; Beaudeux JL; Hennequin C Ann Biol Clin (Paris); 2018 Jun; 76(3):308-312. PubMed ID: 29622524 [TBL] [Abstract][Full Text] [Related]
18. Comparison of the Abbott Architect BRAHMS and the Biomérieux Vidas BRAHMS Procalcitonin Assays. Wang D; Caddell B; Nolte FS; Babic N J Appl Lab Med; 2019 Jan; 3(4):580-586. PubMed ID: 31639727 [TBL] [Abstract][Full Text] [Related]
19. Analytical Evaluation of the New Beckman Coulter Access Procalcitonin (PCT) Chemiluminescent Immunoassay. Lippi G; Salvagno GL; Gelati M; Pucci M; Demonte D; Faggian D; Plebani M Diagnostics (Basel); 2020 Feb; 10(3):. PubMed ID: 32111028 [TBL] [Abstract][Full Text] [Related]
20. [Use of procalcitonine in intensive care units: comparison of semi quantitative PCT-Q Brahms assay with automated PCT-Kryptor assay]. Schuch G; Duc-Marchand C; Venet C; Mann H; Tixier A; Bionda C Ann Biol Clin (Paris); 2011; 69(6):663-70. PubMed ID: 22123565 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]