These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 28861392)
1. The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V). Huang GY; Jiang HB; Cha JY; Kim KM; Hwang CJ Korean J Orthod; 2017 Sep; 47(5):306-312. PubMed ID: 28861392 [TBL] [Abstract][Full Text] [Related]
2. [Effect of fluoride ion on corrosion of two dental titanium alloys]. Cao BW; Chen L Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653 [TBL] [Abstract][Full Text] [Related]
3. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments. Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225 [TBL] [Abstract][Full Text] [Related]
4. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions. Nakagawa M; Matsuya S; Udoh K Dent Mater J; 2001 Dec; 20(4):305-14. PubMed ID: 11915624 [TBL] [Abstract][Full Text] [Related]
5. Comparative corrosion study of Ti-Ta alloys for dental applications. Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903 [TBL] [Abstract][Full Text] [Related]
6. Electrochemical Behaviour of Ti and Ti-6Al-4V Alloy in Phosphate Buffered Saline Solution. Gudić S; Vrsalović L; Kvrgić D; Nagode A Materials (Basel); 2021 Dec; 14(24):. PubMed ID: 34947090 [TBL] [Abstract][Full Text] [Related]
7. Corrosion behavior of pure titanium and titanium alloys in various concentrations of Acidulated Phosphate Fluoride (APF) solutions. Matono Y; Nakagawa M; Matsuya S; Ishikawa K; Terada Y Dent Mater J; 2006 Mar; 25(1):104-12. PubMed ID: 16706304 [TBL] [Abstract][Full Text] [Related]
8. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540 [TBL] [Abstract][Full Text] [Related]
9. [Corrosion resistance of a new Ti-12.5Zr-3Nb-2.5Sn alloy]. Hu X; Wei Q; Li CY; Deng JY; Liu S; Zhang LY Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Sep; 45(9):569-72. PubMed ID: 21122455 [TBL] [Abstract][Full Text] [Related]
10. Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy. Huang HH Biomaterials; 2003 Jan; 24(2):275-82. PubMed ID: 12419628 [TBL] [Abstract][Full Text] [Related]
11. Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride. Takemoto S; Hattori M; Yoshinari M; Kawada E; Asami K; Oda Y Dent Mater J; 2004 Sep; 23(3):379-86. PubMed ID: 15510869 [TBL] [Abstract][Full Text] [Related]
12. Corrosion behavior of novel Ti-24Nb-4Zr-7.9Sn alloy for dental implant applications in vitro. Cheng Y; Hu J; Zhang C; Wang Z; Hao Y; Gao B J Biomed Mater Res B Appl Biomater; 2013 Feb; 101(2):287-94. PubMed ID: 23166067 [TBL] [Abstract][Full Text] [Related]
13. Effect of corrosion on the strength of soldered titanium and Ti-6Al-4V alloy. Oda Y; Okabe T Dent Mater; 1996 May; 12(3):167-72. PubMed ID: 9002859 [TBL] [Abstract][Full Text] [Related]
14. Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys. Nakagawa M; Matsuya S; Udoh K Dent Mater J; 2002 Jun; 21(2):83-92. PubMed ID: 12238790 [TBL] [Abstract][Full Text] [Related]
15. Corrosion resistance of titanium-silver alloys in an artificial saliva containing fluoride ions. Shim HM; Oh KT; Woo JY; Hwang CJ; Kim KN J Biomed Mater Res B Appl Biomater; 2005 May; 73(2):252-9. PubMed ID: 15674839 [TBL] [Abstract][Full Text] [Related]
16. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin. Huang HH; Lee TH Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783 [TBL] [Abstract][Full Text] [Related]
17. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation. Berbel LO; Banczek EDP; Karoussis IK; Kotsakis GA; Costa I PLoS One; 2019; 14(1):e0210530. PubMed ID: 30703125 [TBL] [Abstract][Full Text] [Related]
18. Corrosion resistance characteristics of a Ti-6Al-4V alloy scaffold that is fabricated by electron beam melting and selective laser melting for implantation in vivo. Zhao B; Wang H; Qiao N; Wang C; Hu M Mater Sci Eng C Mater Biol Appl; 2017 Jan; 70(Pt 1):832-841. PubMed ID: 27770961 [TBL] [Abstract][Full Text] [Related]
19. Attachment of Porphyromonas gingivalis to corroded commercially pure titanium and titanium-aluminum-vanadium alloy. Barão VA; Yoon CJ; Mathew MT; Yuan JC; Wu CD; Sukotjo C J Periodontol; 2014 Sep; 85(9):1275-82. PubMed ID: 24444400 [TBL] [Abstract][Full Text] [Related]
20. The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength. Yamazoe J; Nakagawa M; Matono Y; Takeuchi A; Ishikawa K Dent Mater J; 2007 Mar; 26(2):260-7. PubMed ID: 17621943 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]