These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 28862408)

  • 1. Benefits of electroanatomic ablation of conventional cardiac arrhytmias: from fluoroscopy to zero X-ray mapping.
    Casella M; Ribatti V; Catto V; Vettor G; Fassini G; Biagioli V; Dello Russo A; Tondo C
    Minerva Cardioangiol; 2018 Feb; 66(1):49-62. PubMed ID: 28862408
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new electrophysiology era: zero fluoroscopy.
    Anselmino M; Sillano D; Casolati D; Ferraris F; Scaglione M; Gaita F
    J Cardiovasc Med (Hagerstown); 2013 Mar; 14(3):221-7. PubMed ID: 22526222
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implementation of a near-zero fluoroscopy approach in interventional electrophysiology: impact of operator experience.
    Wannagat S; Loehr L; Lask S; Völk K; Karaköse T; Özcelik C; Mügge A; Wutzler A
    J Interv Card Electrophysiol; 2018 Apr; 51(3):215-220. PubMed ID: 29460234
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias.
    Christoph M; Wunderlich C; Moebius S; Forkmann M; Sitzy J; Salmas J; Mayer J; Huo Y; Piorkowski C; Gaspar T
    Europace; 2015 Jun; 17(6):928-37. PubMed ID: 25609207
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reduction of fluoroscopy dose for cardiac electrophysiology procedures: A feasibility and safety study.
    Plank F; Stowasser B; Till D; Schgör W; Dichtl W; Hintringer F; Weiss G; Stühlinger M
    Eur J Radiol; 2019 Jan; 110():105-111. PubMed ID: 30599845
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Near-zero x-ray in arrhythmia ablation using a 3-dimensional electroanatomic mapping system: A multicenter experience.
    Giaccardi M; Del Rosso A; Guarnaccia V; Ballo P; Mascia G; Chiodi L; Colella A
    Heart Rhythm; 2016 Jan; 13(1):150-6. PubMed ID: 26341606
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiofrequency catheter ablation of left-sided accessory pathways in children using a new fluoroscopy integrated 3D-mapping system.
    Drago F; Grifoni G; Remoli R; Russo MS; Righi D; Pazzano V; Palmieri R; Placidi S; Saputo FA; Silvetti MS
    Europace; 2017 Jul; 19(7):1198-1203. PubMed ID: 28201731
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reduction of radiation exposure during atrial fibrillation ablation using a novel fluoroscopy image integrated 3-dimensional electroanatomic mapping system: A prospective, randomized, single-blind, and controlled study.
    Huo Y; Christoph M; Forkmann M; Pohl M; Mayer J; Salmas J; Sitzy J; Wunderlich C; Piorkowski C; Gaspar T
    Heart Rhythm; 2015 Sep; 12(9):1945-55. PubMed ID: 26001508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Getting to zero: impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation.
    Clark BC; Sumihara K; McCarter R; Berul CI; Moak JP
    J Interv Card Electrophysiol; 2016 Aug; 46(2):183-9. PubMed ID: 26768435
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures.
    Bourier F; Reents T; Ammar-Busch S; Buiatti A; Kottmaier M; Semmler V; Telishevska M; Brkic A; Grebmer C; Lennerz C; Kolb C; Hessling G; Deisenhofer I
    Europace; 2016 Sep; 18(9):1406-10. PubMed ID: 26589627
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Minimising radiation exposure in catheter ablation of ventricular arrhythmias.
    Jan M; Žižek D; Prolič Kalinšek T; Kuhelj D; Trunk P; Kolar T; Kšela J; Rauber M; Yazici M
    BMC Cardiovasc Disord; 2021 Jun; 21(1):306. PubMed ID: 34134637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intracardiac Echocardiography to Guide Non-fluoroscopic Electrophysiology Procedures.
    Kautzner J; Haskova J; Lehar F
    Card Electrophysiol Clin; 2021 Jun; 13(2):399-408. PubMed ID: 33990278
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electroanatomic mapping systems (CARTO/EnSite NavX) vs. conventional mapping for ablation procedures in a training program.
    Romero J; Lupercio F; Goodman-Meza D; Ruiz JC; Briceno DF; Fisher JD; Gross J; Ferrick K; Kim S; Di Biase L; Garcia MJ; Krumerman A
    J Interv Card Electrophysiol; 2016 Jan; 45(1):71-80. PubMed ID: 26560500
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Benefit of a General, Systematic Use of Mapping Systems During Electrophysiological Procedures in Children and Teenagers: The Experience of an Adult EP Laboratory.
    Marini M; Del Greco M; Ravanelli D; Cima A; Coser A; Porcedda G; Guarracini F; Valentini A; Bonmassari R
    Pediatr Cardiol; 2016 Apr; 37(4):802-9. PubMed ID: 26932365
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nonfluoroscopic catheter ablation of cardiac arrhythmias in adults: feasibility, safety, and efficacy.
    Razminia M; Manankil MF; Eryazici PL; Arrieta-Garcia C; Wang T; D'Silva OJ; Lopez CS; Crystal GJ; Khan S; Stancu MM; Turner M; Anthony J; Zheutlin TA; Kehoe RF
    J Cardiovasc Electrophysiol; 2012 Oct; 23(10):1078-86. PubMed ID: 22571735
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures.
    Patel AR; Ganley J; Zhu X; Rome JJ; Shah M; Glatz AC
    Pediatr Cardiol; 2014 Oct; 35(7):1116-23. PubMed ID: 24801673
    [TBL] [Abstract][Full Text] [Related]  

  • 17. X-Ray Exposure in Cardiac Electrophysiology: A Retrospective Analysis in 8150 Patients Over 7 Years of Activity in a Modern, Large-Volume Laboratory.
    Casella M; Dello Russo A; Russo E; Catto V; Pizzamiglio F; Zucchetti M; Majocchi B; Riva S; Vettor G; Dessanai MA; Fassini G; Moltrasio M; Tundo F; Vignati C; Conti S; Bonomi A; Carbucicchio C; Di Biase L; Natale A; Tondo C
    J Am Heart Assoc; 2018 May; 7(11):. PubMed ID: 29789334
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Practical guidance to reduce radiation exposure in electrophysiology applying ultra low-dose protocols: a European Heart Rhythm Association review.
    Sommer P; Sciacca V; Anselmino M; Tilz R; Bourier F; Lehrmann H; Bulava A
    Europace; 2023 Jul; 25(7):. PubMed ID: 37410906
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimized Fluoroscopy Setting and Appropriate Project Position Can Reduce X-ray Radiation Doses Rates during Electrophysiology Procedures.
    Hou BB; Yao Y; Wu LM; Qiao Y; Zheng LH; Ding LG; Chen G; Zhang S
    Chin Med J (Engl); 2015 May; 128(9):1151-3. PubMed ID: 25947395
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safe procedures despite ultra low radiation doses during catheter ablations of atrial and ventricular arrhythmias-A multicenter experience.
    Attanasio P; Huemer M; Kaehler N; Keller T; Schreiber T; Niehues R; Katsani-Potempa D; Klein RM; Landmesser U; Deisenhofer I; Tutdibi O; Bourier F
    Pacing Clin Electrophysiol; 2021 May; 44(5):807-813. PubMed ID: 33665850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.