739 related articles for article (PubMed ID: 28869845)
1. A microdevice for rapid, monoplex and colorimetric detection of foodborne pathogens using a centrifugal microfluidic platform.
Sayad A; Ibrahim F; Mukim Uddin S; Cho J; Madou M; Thong KL
Biosens Bioelectron; 2018 Feb; 100():96-104. PubMed ID: 28869845
[TBL] [Abstract][Full Text] [Related]
2. Centrifugal loop-mediated isothermal amplification microdevice for rapid, multiplex and colorimetric foodborne pathogen detection.
Oh SJ; Park BH; Jung JH; Choi G; Lee DC; Kim DH; Seo TS
Biosens Bioelectron; 2016 Jan; 75():293-300. PubMed ID: 26322592
[TBL] [Abstract][Full Text] [Related]
3. Fully automated and colorimetric foodborne pathogen detection on an integrated centrifugal microfluidic device.
Oh SJ; Park BH; Choi G; Seo JH; Jung JH; Choi JS; Kim do H; Seo TS
Lab Chip; 2016 May; 16(10):1917-26. PubMed ID: 27112702
[TBL] [Abstract][Full Text] [Related]
4. An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics.
Park BH; Oh SJ; Jung JH; Choi G; Seo JH; Kim DH; Lee EY; Seo TS
Biosens Bioelectron; 2017 May; 91():334-340. PubMed ID: 28043075
[TBL] [Abstract][Full Text] [Related]
5. Fully integrated and slidable paper-embedded plastic microdevice for point-of-care testing of multiple foodborne pathogens.
Trinh KTL; Trinh TND; Lee NY
Biosens Bioelectron; 2019 Jun; 135():120-128. PubMed ID: 31004922
[TBL] [Abstract][Full Text] [Related]
6. Point-of-care genetic analysis for multiplex pathogenic bacteria on a fully integrated centrifugal microdevice with a large-volume sample.
Nguyen HV; Nguyen VD; Lee EY; Seo TS
Biosens Bioelectron; 2019 Jul; 136():132-139. PubMed ID: 31078871
[TBL] [Abstract][Full Text] [Related]
7. Combination of a centrifugal microfluidic device with a solution-loading cartridge for fully automatic molecular diagnostics.
Oh SJ; Seo TS
Analyst; 2019 Sep; 144(19):5766-5774. PubMed ID: 31436781
[TBL] [Abstract][Full Text] [Related]
8. Paper-Based All-in-One Origami Microdevice for Nucleic Acid Amplification Testing for Rapid Colorimetric Identification of Live Cells for Point-of-Care Testing.
Trieu PT; Lee NY
Anal Chem; 2019 Sep; 91(17):11013-11022. PubMed ID: 31276385
[TBL] [Abstract][Full Text] [Related]
9. A newly developed paper embedded microchip based on LAMP for rapid multiple detections of foodborne pathogens.
Zhang M; Liu J; Shen Z; Liu Y; Song Y; Liang Y; Li Z; Nie L; Fang Y; Zhao Y
BMC Microbiol; 2021 Jun; 21(1):197. PubMed ID: 34182947
[TBL] [Abstract][Full Text] [Related]
10. A foldable isothermal amplification microdevice for fuchsin-based colorimetric detection of multiple foodborne pathogens.
Trinh TND; Lee NY
Lab Chip; 2019 Apr; 19(8):1397-1405. PubMed ID: 30847458
[TBL] [Abstract][Full Text] [Related]
11. A centrifugal direct recombinase polymerase amplification (direct-RPA) microdevice for multiplex and real-time identification of food poisoning bacteria.
Choi G; Jung JH; Park BH; Oh SJ; Seo JH; Choi JS; Kim do H; Seo TS
Lab Chip; 2016 Jun; 16(12):2309-16. PubMed ID: 27216297
[TBL] [Abstract][Full Text] [Related]
12. A rapid and eco-friendly isothermal amplification microdevice for multiplex detection of foodborne pathogens.
Trinh TND; Lee NY
Lab Chip; 2018 Aug; 18(16):2369-2377. PubMed ID: 29923578
[TBL] [Abstract][Full Text] [Related]
13. Micro-nano-bio acoustic system for the detection of foodborne pathogens in real samples.
Papadakis G; Murasova P; Hamiot A; Tsougeni K; Kaprou G; Eck M; Rabus D; Bilkova Z; Dupuy B; Jobst G; Tserepi A; Gogolides E; Gizeli E
Biosens Bioelectron; 2018 Jul; 111():52-58. PubMed ID: 29635118
[TBL] [Abstract][Full Text] [Related]
14. Fully Integrated and Foldable Microdevice Encapsulated with Agarose for Long-Term Storage Potential for Point-of-Care Testing of Multiplex Foodborne Pathogens.
Trinh TND; La HC; Lee NY
ACS Sens; 2019 Oct; 4(10):2754-2762. PubMed ID: 31502446
[TBL] [Abstract][Full Text] [Related]
15. A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform.
Uddin SM; Ibrahim F; Sayad AA; Thiha A; Pei KX; Mohktar MS; Hashim U; Cho J; Thong KL
Sensors (Basel); 2015 Mar; 15(3):5376-89. PubMed ID: 25751077
[TBL] [Abstract][Full Text] [Related]
16. A film-based integrated chip for gene amplification and electrochemical detection of pathogens causing foodborne illnesses.
Park YM; Lim SY; Shin SJ; Kim CH; Jeong SW; Shin SY; Bae NH; Lee SJ; Na J; Jung GY; Lee TJ
Anal Chim Acta; 2018 Oct; 1027():57-66. PubMed ID: 29866270
[TBL] [Abstract][Full Text] [Related]
17. A polymer microfluidic chip for quantitative detection of multiple water- and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification.
Tourlousse DM; Ahmad F; Stedtfeld RD; Seyrig G; Tiedje JM; Hashsham SA
Biomed Microdevices; 2012 Aug; 14(4):769-78. PubMed ID: 22566273
[TBL] [Abstract][Full Text] [Related]
18. Chip-based automated equipment for dual-mode point-of-care testing foodborne pathogens.
Yin B; Zhu H; Zeng S; Sohan ASMMF; Wan X; Liu J; Zhang P; Lin X
Biosens Bioelectron; 2024 Aug; 257():116338. PubMed ID: 38677017
[TBL] [Abstract][Full Text] [Related]
19. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.
Kant K; Shahbazi MA; Dave VP; Ngo TA; Chidambara VA; Than LQ; Bang DD; Wolff A
Biotechnol Adv; 2018; 36(4):1003-1024. PubMed ID: 29534915
[TBL] [Abstract][Full Text] [Related]
20. A single cell droplet microfluidic system for quantitative determination of food-borne pathogens.
An X; Zuo P; Ye BC
Talanta; 2020 Mar; 209():120571. PubMed ID: 31892085
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]