These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 2887083)

  • 1. Tissue reactions to implanted orthodontic wires in rabbits.
    Gjerdet NR; Kallus T; Hensten-Pettersen A
    Acta Odontol Scand; 1987 Jun; 45(3):163-9. PubMed ID: 2887083
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Corrosion of silver soldered orthodontic wires.
    Berge M; Gjerdet NR; Erichsen ES
    Acta Odontol Scand; 1982; 40(2):75-9. PubMed ID: 6125077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material--an in vitro study.
    Dua R; Nandlal B
    J Indian Soc Pedod Prev Dent; 2004 Mar; 22(1):13-6. PubMed ID: 15255439
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Studies on silver soldering of super-elastic Ti-Ni alloy wire to Co-Cr alloy wire].
    Kuroda K
    Kokubyo Gakkai Zasshi; 1994 Dec; 61(4):542-63. PubMed ID: 7897269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Composition and in vitro corrosion of orthodontic appliances.
    Grimsdottir MR; Gjerdet NR; Hensten-Pettersen A
    Am J Orthod Dentofacial Orthop; 1992 Jun; 101(6):525-32. PubMed ID: 1350883
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Failure investigation of soldered stainless steel orthodontic appliances exposed to artificial saliva.
    Vahed A; Lachman N; Knutsen RD
    Dent Mater; 2007 Jul; 23(7):855-61. PubMed ID: 16911820
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corrosion by external polarization of soldered orthodontic wires in cleanser solutions.
    Mueller HJ; Greener EH; Marker BC
    Am J Orthod; 1979 Nov; 76(5):555-64. PubMed ID: 41454
    [No Abstract]   [Full Text] [Related]  

  • 8. Micro-XRD study of beta-titanium wires and infrared soldered joints.
    Iijima M; Brantley WA; Baba N; Alapati SB; Yuasa T; Ohno H; Mizoguchi I
    Dent Mater; 2007 Sep; 23(9):1051-6. PubMed ID: 17178150
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Corrosion properties of soldered joints. Part II: Corrosion pattern of dental solder and dental nickel-chromium alloy.
    Shigeto N; Yanagihara T; Murakami S; Hamada T
    J Prosthet Dent; 1991 Nov; 66(5):607-10. PubMed ID: 1687152
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corrosion properties of soldered joints. Part I: Electrochemical action of dental solder and dental nickel-chromium alloy.
    Shigeto N; Yanagihara T; Hamada T; Budtz-Jørgensen E
    J Prosthet Dent; 1989 Nov; 62(5):512-5. PubMed ID: 2575168
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical properties and clinical applications of orthodontic wires.
    Kapila S; Sachdeva R
    Am J Orthod Dentofacial Orthop; 1989 Aug; 96(2):100-9. PubMed ID: 2667330
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of tack welding and increasing surface area on the tensile strength of silver electric and flame soldered stainless steel joints.
    Gawlik JA; Mathieu GP; Hondrum S
    Pediatr Dent; 1996; 18(3):215-8. PubMed ID: 8784912
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Materials science studies on the soldering of different orthodontic wires].
    Hannemann M; Minarski P; Lugscheider E; Diedrich P
    Fortschr Kieferorthop; 1989 Dec; 50(6):506-17. PubMed ID: 2575567
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tensile strength of soldered joints.
    O'Toole TJ; Furnish GM; von Fraunhofer JA
    J Prosthet Dent; 1985 Mar; 53(3):350-2. PubMed ID: 2859365
    [No Abstract]   [Full Text] [Related]  

  • 15. Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys.
    Kapila S; Angolkar PV; Duncanson MG; Nanda RS
    Am J Orthod Dentofacial Orthop; 1990 Aug; 98(2):117-26. PubMed ID: 2378317
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires.
    Kim H; Johnson JW
    Angle Orthod; 1999 Feb; 69(1):39-44. PubMed ID: 10022183
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nickel hypersensitivity reaction before, during, and after orthodontic therapy.
    Janson GR; Dainesi EA; Consolaro A; Woodside DG; de Freitas MR
    Am J Orthod Dentofacial Orthop; 1998 Jun; 113(6):655-60. PubMed ID: 9637569
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relative kinetic frictional forces between sintered stainless steel brackets and orthodontic wires.
    Vaughan JL; Duncanson MG; Nanda RS; Currier GF
    Am J Orthod Dentofacial Orthop; 1995 Jan; 107(1):20-7. PubMed ID: 7817958
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative friction of orthodontic wires under dry and wet conditions.
    Stannard JG; Gau JM; Hanna MA
    Am J Orthod; 1986 Jun; 89(6):485-91. PubMed ID: 3459362
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro toxicity evaluation of silver soldering, electrical resistance, and laser welding of orthodontic wires.
    Sestini S; Notarantonio L; Cerboni B; Alessandrini C; Fimiani M; Nannelli P; Pelagalli A; Giorgetti R
    Eur J Orthod; 2006 Dec; 28(6):567-72. PubMed ID: 17035485
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.