BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 28874164)

  • 1. Radiation-free CMR diagnostic heart catheterization in children.
    Ratnayaka K; Kanter JP; Faranesh AZ; Grant EK; Olivieri LJ; Cross RR; Cronin IF; Hamann KS; Campbell-Washburn AE; O'Brien KJ; Rogers T; Hansen MS; Lederman RJ
    J Cardiovasc Magn Reson; 2017 Sep; 19(1):65. PubMed ID: 28874164
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Invasive cardiovascular magnetic resonance (iCMR) for diagnostic right and left heart catheterization using an MR-conditional guidewire and passive visualization in congenital heart disease.
    Veeram Reddy SR; Arar Y; Zahr RA; Gooty V; Hernandez J; Potersnak A; Douglas P; Blair Z; Greer JS; Roujol S; Forte MNV; Greil G; Nugent AW; Hussain T
    J Cardiovasc Magn Reson; 2020 Mar; 22(1):20. PubMed ID: 32213193
    [TBL] [Abstract][Full Text] [Related]  

  • 3. CMR fluoroscopy right heart catheterization for cardiac output and pulmonary vascular resistance: results in 102 patients.
    Rogers T; Ratnayaka K; Khan JM; Stine A; Schenke WH; Grant LP; Mazal JR; Grant EK; Campbell-Washburn A; Hansen MS; Ramasawmy R; Herzka DA; Xue H; Kellman P; Faranesh AZ; Lederman RJ
    J Cardiovasc Magn Reson; 2017 Jul; 19(1):54. PubMed ID: 28750642
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time MRI-guided right heart catheterization in adults using passive catheters.
    Ratnayaka K; Faranesh AZ; Hansen MS; Stine AM; Halabi M; Barbash IM; Schenke WH; Wright VJ; Grant LP; Kellman P; Kocaturk O; Lederman RJ
    Eur Heart J; 2013 Feb; 34(5):380-9. PubMed ID: 22855740
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Right heart catheterization using metallic guidewires and low SAR cardiovascular magnetic resonance fluoroscopy at 1.5 Tesla: first in human experience.
    Campbell-Washburn AE; Rogers T; Stine AM; Khan JM; Ramasawmy R; Schenke WH; McGuirt DR; Mazal JR; Grant LP; Grant EK; Herzka DA; Lederman RJ
    J Cardiovasc Magn Reson; 2018 Jun; 20(1):41. PubMed ID: 29925397
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiovascular magnetic resonance-guided right heart catheterization in a conventional CMR environment - predictors of procedure success and duration in pulmonary artery hypertension.
    Knight DS; Kotecha T; Martinez-Naharro A; Brown JT; Bertelli M; Fontana M; Muthurangu V; Coghlan JG
    J Cardiovasc Magn Reson; 2019 Sep; 21(1):57. PubMed ID: 31495338
    [TBL] [Abstract][Full Text] [Related]  

  • 7. X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions.
    Grant EK; Kanter JP; Olivieri LJ; Cross RR; Campbell-Washburn A; Faranesh AZ; Cronin I; Hamann KS; O'Byrne ML; Slack MC; Lederman RJ; Ratnayaka K
    Catheter Cardiovasc Interv; 2019 Sep; 94(3):399-408. PubMed ID: 31062506
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility, safety and diagnostic yield of interventional cardiac magnetic resonance for routine right heart catheterization in adults.
    Sanguineti F; Garot P; Toupin S; Pezel T; Bohbot Y; Tawa C; Poupineau M; Boileve V; Landon V; Duhamel S; Garot J
    Arch Cardiovasc Dis; 2024 Apr; 117(4):275-282. PubMed ID: 38472043
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improved passive catheter tracking with positive contrast for CMR-guided cardiac catheterization using partial saturation (pSAT).
    Velasco Forte MN; Pushparajah K; Schaeffter T; Valverde Perez I; Rhode K; Ruijsink B; Alhrishy M; Byrne N; Chiribiri A; Ismail T; Hussain T; Razavi R; Roujol S
    J Cardiovasc Magn Reson; 2017 Aug; 19(1):60. PubMed ID: 28806996
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anesthetic considerations for magnetic resonance imaging-guided right-heart catheterization in pediatric patients: A single institution experience.
    Deutsch N; Swink J; Matisoff AJ; Olivieri LJ; Cross RR; Waberski AT; Unegbu C; Cronin IF; Kanter JP; Schwartz JM
    Paediatr Anaesth; 2019 Jan; 29(1):8-15. PubMed ID: 30375141
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved catheter tracking during cardiovascular magnetic resonance-guided cardiac catheterization using overlay visualization.
    Greer JS; Hussein MA; Vamsee R; Arar Y; Krueger S; Weiss S; Dillenbeck J; Greil G; Veeram Reddy SR; Hussain T
    J Cardiovasc Magn Reson; 2022 Jun; 24(1):32. PubMed ID: 35650624
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series.
    Hilbert S; Sommer P; Gutberlet M; Gaspar T; Foldyna B; Piorkowski C; Weiss S; Lloyd T; Schnackenburg B; Krueger S; Fleiter C; Paetsch I; Jahnke C; Hindricks G; Grothoff M
    Europace; 2016 Apr; 18(4):572-7. PubMed ID: 26316146
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MRI for Guided Right and Left Heart Cardiac Catheterization: A Prospective Study in Congenital Heart Disease.
    Velasco Forte MN; Roujol S; Ruijsink B; Valverde I; Duong P; Byrne N; Krueger S; Weiss S; Arar Y; Reddy SRV; Schaeffter T; Hussain T; Razavi R; Pushparajah K
    J Magn Reson Imaging; 2021 May; 53(5):1446-1457. PubMed ID: 33155758
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiovascular magnetic resonance catheterization derived pulmonary vascular resistance and medium-term outcomes in congenital heart disease.
    Pushparajah K; Tzifa A; Bell A; Wong JK; Hussain T; Valverde I; Bellsham-Revell HR; Greil G; Simpson JM; Schaeffter T; Razavi R
    J Cardiovasc Magn Reson; 2015 Apr; 17(1):28. PubMed ID: 25890289
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reducing Radiation Exposure in Cardiac Catheterizations for Congenital Heart Disease.
    Patel C; Grossman M; Shabanova V; Asnes J
    Pediatr Cardiol; 2019 Mar; 40(3):638-649. PubMed ID: 30542920
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dual echo positive contrast bSSFP for real-time visualization of passive devices during magnetic resonance guided cardiovascular catheterization.
    Campbell-Washburn AE; Rogers T; Xue H; Hansen MS; Lederman RJ; Faranesh AZ
    J Cardiovasc Magn Reson; 2014 Oct; 16(1):88. PubMed ID: 25359137
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three-Dimensional Echocardiographic Guidance of Right Heart Catheterization Decreases Radiation Exposure in Atrial Septal Defect Closures.
    Jone PN; Zablah JE; Burkett DA; Schäfer M; Wilson N; Morgan GJ; Ross M
    J Am Soc Echocardiogr; 2018 Sep; 31(9):1044-1049. PubMed ID: 29958759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulse fluoroscopy radiation reduction in a pediatric cardiac catheterization laboratory.
    Covi SH; Whiteside W; Yu S; Zampi JD
    Congenit Heart Dis; 2015; 10(2):E43-7. PubMed ID: 24965688
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MRI Catheterization: Ready for Broad Adoption.
    Nageotte SJ; Lederman RJ; Ratnayaka K
    Pediatr Cardiol; 2020 Mar; 41(3):503-513. PubMed ID: 32198594
    [TBL] [Abstract][Full Text] [Related]  

  • 20. X-ray magnetic resonance fusion modality may reduce radiation exposure and contrast dose in diagnostic cardiac catheterization of congenital heart disease.
    Abu Hazeem AA; Dori Y; Whitehead KK; Harris MA; Fogel MA; Gillespie MJ; Rome JJ; Glatz AC
    Catheter Cardiovasc Interv; 2014 Nov; 84(5):795-800. PubMed ID: 24619541
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.