These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 28890122)

  • 1. Lumbar segmental artery pseudoaneurysm after L5 pedicle screw placement. A rare vascular complication.
    Álvarez Postigo M; Pizones Arce J; Izquierdo Núñez E
    Rev Esp Cir Ortop Traumatol; 2017; 61(6):436-440. PubMed ID: 28890122
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of major vascular injury during pedicle screw instrumentation of thoracolumbar spine.
    Mirza AK; Alvi MA; Naylor RM; Kerezoudis P; Krauss WE; Clarke MJ; Shepherd DL; Nassr A; DeMartino RR; Bydon M
    Clin Neurol Neurosurg; 2017 Dec; 163():53-59. PubMed ID: 29073499
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Management of lumbar artery injury related to pedicle screw insertion.
    Sugimoto Y; Tanaka M; Gobara H; Misawa H; Kunisada T; Ozaki T
    Acta Med Okayama; 2013; 67(2):113-6. PubMed ID: 23603928
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws.
    Parker SL; Amin AG; Santiago-Dieppa D; Liauw JA; Bydon A; Sciubba DM; Wolinsky JP; Gokaslan ZL; Witham TF
    Spine (Phila Pa 1976); 2014 Apr; 39(8):683-7. PubMed ID: 24480963
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An Unusual Case of Ureteral Perforation in Minimally Invasive Pedicle Screw Instrumentation: Case Report and Review of the Literature.
    Fomekong E; Pierrard J; Danse E; Tombal B; Raftopoulos C
    World Neurosurg; 2018 Mar; 111():28-35. PubMed ID: 29229340
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates.
    Raley DA; Mobbs RJ
    Spine (Phila Pa 1976); 2012 May; 37(12):1092-100. PubMed ID: 22037528
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of pedicle screw placement in the thoracic and lumbosacral spine using a conventional intraoperative fluoroscopy-guided technique: a national neurosurgical education and training center analysis of 1236 consecutive screws.
    Nevzati E; Marbacher S; Soleman J; Perrig WN; Diepers M; Khamis A; Fandino J
    World Neurosurg; 2014 Nov; 82(5):866-71.e1-2. PubMed ID: 24954252
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Delayed Presentation of Thoracic Aortic Pseudoaneurysm Following Pedicle Screw Implantation: A Case Report.
    Liu LD; Hong X; Li JB; Zhang SK
    Orthop Surg; 2021 Feb; 13(1):338-341. PubMed ID: 33410291
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Posterior lumbar interbody fusion with cortical bone trajectory screw fixation versus posterior lumbar interbody fusion using traditional pedicle screw fixation for degenerative lumbar spondylolisthesis: a comparative study.
    Sakaura H; Miwa T; Yamashita T; Kuroda Y; Ohwada T
    J Neurosurg Spine; 2016 Nov; 25(5):591-595. PubMed ID: 27231813
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time.
    Spitz SM; Sandhu FA; Voyadzis JM
    J Neurosurg Spine; 2015 Apr; 22(4):422-31. PubMed ID: 25658468
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Posterior lumbar fusion using the O-arm surgical imaging system: initial experience].
    Castro Castro J; Rodino Padín J; Pinzón Millán A; Agulleiro Díaz JP; Villa Fernández JM; Pastor Zapata A
    Neurocirugia (Astur); 2013; 24(1):1-8. PubMed ID: 23246338
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique.
    Modi HN; Suh SW; Fernandez H; Yang JH; Song HR
    Eur Spine J; 2008 Dec; 17(12):1686-96. PubMed ID: 18830636
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal "Low" Pedicle Screw Stimulation Threshold to Predict New Postoperative Lower-Extremity Neurologic Deficits During Lumbar Spinal Fusions.
    Melachuri SR; Melachuri MK; Mina A; Anetakis K; Crammond DJ; Balzer JR; Shandal V; Thirumala PD
    World Neurosurg; 2021 Jul; 151():e250-e256. PubMed ID: 33872842
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
    Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
    Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery.
    Tormenti MJ; Kostov DB; Gardner PA; Kanter AS; Spiro RM; Okonkwo DO
    Neurosurg Focus; 2010 Mar; 28(3):E11. PubMed ID: 20192656
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence and Risk Factors for Facet Joint Violation in Open Versus Minimally Invasive Procedures During Pedicle Screw Placement in Patients with Trauma.
    Herren C; Reijnen M; Pishnamaz M; Lichte P; Andruszkow H; Nebelung S; Siewe J; Hildebrand F; Kobbe P
    World Neurosurg; 2018 Apr; 112():e711-e718. PubMed ID: 29391300
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe?
    Karapinar L; Erel N; Ozturk H; Altay T; Kaya A
    J Spinal Disord Tech; 2008 Feb; 21(1):63-7. PubMed ID: 18418139
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of single-time, multilevel registration in image-guided spinal surgery.
    Papadopoulos EC; Girardi FP; Sama A; Sandhu HS; Cammisa FP
    Spine J; 2005; 5(3):263-7; discussion 268. PubMed ID: 15863081
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A distraction technique using reduction multi-axial screws for open reduction of high-grade lumbar posterior dislocation:a case report and literature review.
    Zhou Z; Wang Y; Sun Z; Zhu X; Qian Z
    BMC Musculoskelet Disord; 2019 Nov; 20(1):545. PubMed ID: 31731891
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws.
    Bydon M; Xu R; Amin AG; Macki M; Kaloostian P; Sciubba DM; Wolinsky JP; Bydon A; Gokaslan ZL; Witham TF
    J Neurosurg Spine; 2014 Sep; 21(3):320-8. PubMed ID: 24926927
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.