These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 2889234)

  • 1. Electron-transfer biosensors.
    Frew JE; Hill HA
    Philos Trans R Soc Lond B Biol Sci; 1987 Aug; 316(1176):95-106. PubMed ID: 2889234
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct and indirect electron transfer between electrodes and redox proteins.
    Frew JE; Hill HA
    Eur J Biochem; 1988 Mar; 172(2):261-9. PubMed ID: 3280307
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct electrochemical probes of redox protein and redox enzyme structure and function.
    Barker PD; Hill HA
    Prog Clin Biol Res; 1988; 274():419-33. PubMed ID: 3406032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct electrochemistry and intramolecular electron transfer of ascorbate oxidase confined on L-cysteine self-assembled gold electrode.
    Patil B; Kobayashi Y; Fujikawa S; Okajima T; Mao L; Ohsaka T
    Bioelectrochemistry; 2014 Feb; 95():15-22. PubMed ID: 24189123
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Small electron-transfer proteins as mediators in enzymatic electrochemical biosensors.
    Silveira CM; Almeida MG
    Anal Bioanal Chem; 2013 Apr; 405(11):3619-35. PubMed ID: 23430181
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination.
    Manjunatha R; Shivappa Suresh G; Melo JS; D'Souza SF; Venkatesha TV
    Talanta; 2012 Sep; 99():302-9. PubMed ID: 22967556
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Designing electrochemical interfaces with functionalized magnetic nanoparticles and wrapped carbon nanotubes as platforms for the construction of high-performance bienzyme biosensors.
    Eguílaz M; Villalonga R; Yáñez-Sedeño P; Pingarrón JM
    Anal Chem; 2011 Oct; 83(20):7807-14. PubMed ID: 21905724
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improving enzyme-electrode contacts by redox modification of cofactors.
    Riklin A; Katz E; Willner I; Stocker A; Bückmann AF
    Nature; 1995 Aug; 376(6542):672-5. PubMed ID: 7651516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bioelectrocatalysis by redox enzymes at modified electrodes.
    Scheller FW; Wollenberger U; Lei C; Jin W; Ge B; Lehmann C; Lisdat F; Fridman V
    J Biotechnol; 2002 Feb; 82(4):411-24. PubMed ID: 11996219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Immobilization of glucose oxidase on electrodeposited nickel oxide nanoparticles: direct electron transfer and electrocatalytic activity.
    Salimi A; Sharifi E; Noorbakhsh A; Soltanian S
    Biosens Bioelectron; 2007 Jun; 22(12):3146-53. PubMed ID: 17368016
    [TBL] [Abstract][Full Text] [Related]  

  • 11. β-galactosidase determination by an electrochemical biosensor mediated with ferrocene.
    Sezgintürk MK; Dinçkaya E
    Artif Cells Blood Substit Immobil Biotechnol; 2011 Oct; 39(5):267-73. PubMed ID: 21338333
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Amperometric enzyme biosensors based on optimised electron-transfer pathways and non-manual immobilisation procedures.
    Schuhmann W
    J Biotechnol; 2002 Feb; 82(4):425-41. PubMed ID: 11996220
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Immobilization of horseradish peroxidase on multi-wall carbon nanotubes and its electrochemical properties.
    Lee YM; Kwon OY; Yoon YJ; Ryu K
    Biotechnol Lett; 2006 Jan; 28(1):39-43. PubMed ID: 16369873
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct electrochemistry and electrocatalysis of glucose oxidase immobilized on reduced graphene oxide and silver nanoparticles nanocomposite modified electrode.
    Palanisamy S; Karuppiah C; Chen SM
    Colloids Surf B Biointerfaces; 2014 Feb; 114():164-9. PubMed ID: 24184536
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Polyazetidine-based immobilization of redox proteins for electron-transfer-based biosensors.
    Frasconi M; Favero G; Di Fusco M; Mazzei F
    Biosens Bioelectron; 2009 Jan; 24(5):1424-30. PubMed ID: 18829298
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Direct electron transfer between copper-containing proteins and electrodes.
    Shleev S; Tkac J; Christenson A; Ruzgas T; Yaropolov AI; Whittaker JW; Gorton L
    Biosens Bioelectron; 2005 Jun; 20(12):2517-54. PubMed ID: 15854824
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Direct electron transfer at a glucose oxidase-chitosan-modified Vulcan carbon paste electrode for electrochemical biosensing of glucose.
    Mutyala S; Mathiyarasu J
    Appl Biochem Biotechnol; 2014 Feb; 172(3):1517-29. PubMed ID: 24222502
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effective Electrochemistry of Human Sulfite Oxidase Immobilized on Quantum-Dots-Modified Indium Tin Oxide Electrode.
    Zeng T; Leimkühler S; Koetz J; Wollenberger U
    ACS Appl Mater Interfaces; 2015 Sep; 7(38):21487-94. PubMed ID: 26357959
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electronically type-sorted carbon nanotube-based electrochemical biosensors with glucose oxidase and dehydrogenase.
    Muguruma H; Hoshino T; Nowaki K
    ACS Appl Mater Interfaces; 2015 Jan; 7(1):584-92. PubMed ID: 25522366
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Concepts of electrically connecting redox enzymes to metal electrodes.
    Heller A
    Am Biotechnol Lab; 1990 Jun; 8(8):14-6. PubMed ID: 1366597
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.