These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 28894320)

  • 1. Effect of Tubing Flush or Preconditioning on Available Insulin Concentration for IV Infusion: A Pilot Project.
    Newby B; Holmes DT
    Can J Hosp Pharm; 2017; 70(4):320-321. PubMed ID: 28894320
    [No Abstract]   [Full Text] [Related]  

  • 2. The effect of tubing dwell time on insulin adsorption during intravenous insulin infusions.
    Thompson CD; Vital-Carona J; Faustino EV
    Diabetes Technol Ther; 2012 Oct; 14(10):912-6. PubMed ID: 22746979
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Infection related to intravascular pressure monitoring: effects of flush and tubing changes.
    Covey M; McLane C; Smith N; Matasic J; Holm K
    Am J Infect Control; 1988 Oct; 16(5):206-13. PubMed ID: 3195780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Administration of IV medications via soluset.
    Ford NA; Drott HR; Cieplinski-Robertson JA
    Pediatr Nurs; 2003; 29(4):283-6, 319. PubMed ID: 12956548
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of flow rate and insulin priming on the recovery of insulin from microbore infusion tubing.
    Fuloria M; Friedberg MA; DuRant RH; Aschner JL
    Pediatrics; 1998 Dec; 102(6):1401-6. PubMed ID: 9832576
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal frequency of changing intravenous administration sets: is it safe to prolong use beyond 72 hours?
    Raad I; Hanna HA; Awad A; Alrahwan A; Bivins C; Khan A; Richardson D; Umphrey JL; Whimbey E; Mansour G
    Infect Control Hosp Epidemiol; 2001 Mar; 22(3):136-9. PubMed ID: 11310690
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Insulin infusions in the neonatal unit: delivery variation due to adsorption.
    Hewson M; Nawadra V; Oliver J; Odgers C; Plummer J; Simmer K
    J Paediatr Child Health; 2000 Jun; 36(3):216-20. PubMed ID: 10849219
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Taste and/or Odour Disturbances in Pediatric Patients Undergoing IV Flush with Normal Saline Administered by Prefilled Syringe.
    Celetti SJ; Vaillancourt R; Pascuet E; Sharp D
    Can J Hosp Pharm; 2012 Sep; 65(5):368-72. PubMed ID: 23129865
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Taste and Odour Disturbances in Pediatric Patients Undergoing IV Flush with Normal Saline Administered by Prefilled or Freshly Prepared Syringes: Randomized Single-Blind Study.
    Mancini D; Vaillancourt R; Pouliot A; Lin A; Sharp D
    Can J Hosp Pharm; 2014 Sep; 67(5):353-7. PubMed ID: 25364017
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flush volumes delivered from pressurized bag pump flush systems in neonates and small children.
    Cornelius A; Balmer C; Hug MI; Gerber ACh; Weiss M
    Paediatr Anaesth; 2002 Oct; 12(8):718-23. PubMed ID: 12472710
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of recombinant factor VIII (Kogenate) stability for continuous infusion using a minipump infusion device.
    Hurst D; Zabor S; Malianni D; Miller D
    Haemophilia; 1998 Nov; 4(6):785-9. PubMed ID: 10028298
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Active warming of saline or blood is ineffective when standard infusion tubing is used: an experimental study.
    Bissonnette B; Paut O
    Can J Anaesth; 2002 Mar; 49(3):270-5. PubMed ID: 11861345
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of Drug Concentration, Rate of Infusion, and Flush Volume on G-CSF Drug Loss When Administered Intravenously.
    Saelue P; Sripakdee W; Suknuntha K
    Hosp Pharm; 2019 Dec; 54(6):393-397. PubMed ID: 31762488
    [No Abstract]   [Full Text] [Related]  

  • 14. Effect of tubing length on adsorption of diazepam to polyvinyl chloride administration sets.
    Yliruusi JK; Uotila JA; Kristoffersson ER
    Am J Hosp Pharm; 1986 Nov; 43(11):2789-94. PubMed ID: 3799616
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of high infusion pressure and large-bore tubing on intravenous flow rates.
    Mateer JR; Thompson BM; Tucker J; Aprahamian C; Darin JC
    Am J Emerg Med; 1985 May; 3(3):187-9. PubMed ID: 3994794
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Venous air embolism during home infusion therapy.
    Laskey AL; Dyer C; Tobias JD
    Pediatrics; 2002 Jan; 109(1):E15. PubMed ID: 11773583
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Factors affecting drug delivery from a syringe-pump infusion set.
    Geater RE; Leff RD; Roberts RJ
    Am J Hosp Pharm; 1985 Nov; 42(11):2510-3. PubMed ID: 4073070
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The management of diabetic ketoacidosis by continuous infusion of low-dose insulin using the ordinary intravenous plastic bag and tubing.
    Mengistu M
    Ethiop Med J; 1991 Jan; 29(1):7-13. PubMed ID: 1900469
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Heating Intravenous Fluid Tubing in an Experimental Setting for Prehospital Hypothermia.
    Rodriguez A; Algaze I; Almog R; Katzer RJ
    Air Med J; 2021; 40(1):41-44. PubMed ID: 33455624
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of tubing on loss of clonazepam administered by continuous subcutaneous infusion.
    Schneider JJ; Good P; Ravenscroft PJ
    J Pain Symptom Manage; 2006 Jun; 31(6):563-7. PubMed ID: 16793496
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.