246 related articles for article (PubMed ID: 28900359)
1. Effectiveness of ATP bioluminescence to assess hospital cleaning: a review.
Nante N; Ceriale E; Messina G; Lenzi D; Manzi P
J Prev Med Hyg; 2017 Jun; 58(2):E177-E183. PubMed ID: 28900359
[TBL] [Abstract][Full Text] [Related]
2. Use of ATP bioluminescence for assessing the cleanliness of hospital surfaces: a review of the published literature (1990-2012).
Amodio E; Dino C
J Infect Public Health; 2014; 7(2):92-8. PubMed ID: 24231159
[TBL] [Abstract][Full Text] [Related]
3. The use of adenosine triphosphate bioluminescence to assess the efficacy of a modified cleaning program implemented within an intensive care setting.
Moore G; Smyth D; Singleton J; Wilson P
Am J Infect Control; 2010 Oct; 38(8):617-22. PubMed ID: 20605265
[TBL] [Abstract][Full Text] [Related]
4. Comparing visual inspection, aerobic colony counts, and adenosine triphosphate bioluminescence assay for evaluating surface cleanliness at a medical center.
Huang YS; Chen YC; Chen ML; Cheng A; Hung IC; Wang JT; Sheng WH; Chang SC
Am J Infect Control; 2015 Aug; 43(8):882-6. PubMed ID: 25952617
[TBL] [Abstract][Full Text] [Related]
5. ATP bioluminescence assay for evaluating cleaning practices in operating theatres: applicability and limitations.
Sanna T; Dallolio L; Raggi A; Mazzetti M; Lorusso G; Zanni A; Farruggia P; Leoni E
BMC Infect Dis; 2018 Nov; 18(1):583. PubMed ID: 30453892
[TBL] [Abstract][Full Text] [Related]
6. Application of a fluorescent marker with quantitative bioburden methods to assess cleanliness.
Hung IC; Chang HY; Cheng A; Chen AC; Ting L; Chen MW; Lai YH; Sheng WH
Infect Control Hosp Epidemiol; 2018 Nov; 39(11):1296-1300. PubMed ID: 30221609
[TBL] [Abstract][Full Text] [Related]
7. Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay.
Boyce JM; Havill NL; Dumigan DG; Golebiewski M; Balogun O; Rizvani R
Infect Control Hosp Epidemiol; 2009 Jul; 30(7):678-84. PubMed ID: 19489715
[TBL] [Abstract][Full Text] [Related]
8. The adenosine triphosphate method as a quality control tool to assess 'cleanliness' of frequently touched hospital surfaces.
Knape L; Hambraeus A; Lytsy B
J Hosp Infect; 2015 Oct; 91(2):166-70. PubMed ID: 26213368
[TBL] [Abstract][Full Text] [Related]
9. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.
Richard RD; Bowen TR
Clin Orthop Relat Res; 2017 Jul; 475(7):1819-1824. PubMed ID: 28050814
[TBL] [Abstract][Full Text] [Related]
10. A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces.
Lewis T; Griffith C; Gallo M; Weinbren M
J Hosp Infect; 2008 Jun; 69(2):156-63. PubMed ID: 18468725
[TBL] [Abstract][Full Text] [Related]
11. Analytical performance issues: comparison of ATP bioluminescence and aerobic bacterial count for evaluating surface cleanliness in an Italian hospital.
Amodio E; Cannova L; Villafrate MR; Merendino AM; Aprea L; Calamusa G
J Occup Environ Hyg; 2014; 11(2):D23-7. PubMed ID: 24369935
[TBL] [Abstract][Full Text] [Related]
12. Diagnostic assessment of different environmental cleaning monitoring methods.
Luick L; Thompson PA; Loock MH; Vetter SL; Cook J; Guerrero DM
Am J Infect Control; 2013 Aug; 41(8):751-2. PubMed ID: 23380380
[TBL] [Abstract][Full Text] [Related]
13. Assessing the effectiveness of surface cleaning methods in intravitreal injection procedure rooms.
Amin SR; Folkert CM; Erie JC
Ophthalmology; 2014 Jan; 121(1):276-282. PubMed ID: 24112945
[TBL] [Abstract][Full Text] [Related]
14. [Adenosine triphosphate bioluminescence to evaluate the effectiveness of surface cleaning: an integrative review].
Oliveira AC; Viana Rel H
Rev Bras Enferm; 2014; 67(6):987-93. PubMed ID: 25590891
[TBL] [Abstract][Full Text] [Related]
15. Comparing visual inspection and performance observation for evaluation of hospital cleanliness.
Chen YC; Huang HM; Lin PY; Shi ZY
Am J Infect Control; 2021 Dec; 49(12):1511-1514. PubMed ID: 34314756
[TBL] [Abstract][Full Text] [Related]
16. Finding a benchmark for monitoring hospital cleanliness.
Mulvey D; Redding P; Robertson C; Woodall C; Kingsmore P; Bedwell D; Dancer SJ
J Hosp Infect; 2011 Jan; 77(1):25-30. PubMed ID: 21129820
[TBL] [Abstract][Full Text] [Related]
17. Monitoring the effectiveness of cleaning in four British hospitals.
Cooper RA; Griffith CJ; Malik RE; Obee P; Looker N
Am J Infect Control; 2007 Jun; 35(5):338-41. PubMed ID: 17577482
[TBL] [Abstract][Full Text] [Related]
18. Use of audit tools to evaluate the efficacy of cleaning systems in hospitals.
Malik RE; Cooper RA; Griffith CJ
Am J Infect Control; 2003 May; 31(3):181-7. PubMed ID: 12734526
[TBL] [Abstract][Full Text] [Related]
19. Comparison of fluorescent marker systems with 2 quantitative methods of assessing terminal cleaning practices.
Boyce JM; Havill NL; Havill HL; Mangione E; Dumigan DG; Moore BA
Infect Control Hosp Epidemiol; 2011 Dec; 32(12):1187-93. PubMed ID: 22080657
[TBL] [Abstract][Full Text] [Related]
20. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care.
Watanabe R; Shimoda T; Yano R; Hayashi Y; Nakamura S; Matsuo J; Yamaguchi H
BMC Res Notes; 2014 Mar; 7():121. PubMed ID: 24593868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]