295 related articles for article (PubMed ID: 28901351)
1. All-solid-state ion-selective electrodes with redox-active lithium, sodium, and potassium insertion materials as the inner solid-contact layer.
Komaba S; Akatsuka T; Ohura K; Suzuki C; Yabuuchi N; Kanazawa S; Tsuchiya K; Hasegawa T
Analyst; 2017 Oct; 142(20):3857-3866. PubMed ID: 28901351
[TBL] [Abstract][Full Text] [Related]
2. Stability of the inner polyaniline solid contact layer in all-solid-state K+-selective electrodes based on plasticized poly(vinyl chloride).
Lindfors T; Ivaska A
Anal Chem; 2004 Aug; 76(15):4387-94. PubMed ID: 15283577
[TBL] [Abstract][Full Text] [Related]
3. Multi-analyte biochip (MAB) based on all-solid-state ion-selective electrodes (ASSISE) for physiological research.
Wan Salim WW; Zeitchek MA; Hermann AC; Ricco AJ; Tan M; Selch F; Fleming E; Bebout BM; Bader MM; Ul Haque A; Porterfield DM
J Vis Exp; 2013 Apr; (74):. PubMed ID: 23628944
[TBL] [Abstract][Full Text] [Related]
4. All-solid-state potassium-selective electrode using graphene as the solid contact.
Li F; Ye J; Zhou M; Gan S; Zhang Q; Han D; Niu L
Analyst; 2012 Feb; 137(3):618-23. PubMed ID: 22140676
[TBL] [Abstract][Full Text] [Related]
5. Highly-stable Li
Criscuolo F; Taurino I; Stradolini F; Carrara S; De Micheli G
Anal Chim Acta; 2018 Oct; 1027():22-32. PubMed ID: 29866266
[TBL] [Abstract][Full Text] [Related]
6. All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant.
Abdalla NS; Youssef MA; Algarni H; Awwad NS; Kamel AH
Molecules; 2019 Feb; 24(4):. PubMed ID: 30781449
[TBL] [Abstract][Full Text] [Related]
7. Emulsion Doping of Ionophores and Ion-Exchangers into Ion-Selective Electrode Membranes.
Soda Y; Gao W; Bosset J; Bakker E
Anal Chem; 2020 Nov; 92(21):14319-14324. PubMed ID: 33084307
[TBL] [Abstract][Full Text] [Related]
8. Application of nanostructured TCNQ to potentiometric ion-selective K(+) and Na(+) electrodes.
Paczosa-Bator B; Pięk M; Piech R
Anal Chem; 2015 Feb; 87(3):1718-25. PubMed ID: 25551547
[TBL] [Abstract][Full Text] [Related]
9. A comparative study of solid and liquid inner contact benzalkonium chloride ion-selective electrode membranes.
Abu Shawish HM; Khedr AM; Abed-Almonem KI; Gaber M
Talanta; 2012 Nov; 101():211-9. PubMed ID: 23158314
[TBL] [Abstract][Full Text] [Related]
10. An experimental study of membrane materials and inner contacting layers for ion-selective K+ electrodes with a stable response and good dynamic range.
Michalska AJ; Appaih-Kusi C; Heng LY; Walkiewicz S; Hall EA
Anal Chem; 2004 Apr; 76(7):2031-9. PubMed ID: 15053668
[TBL] [Abstract][Full Text] [Related]
11. Potassium-selective electrodes with stable and geometrically well-defined internal solid contact based on nanoparticles of polyaniline and plasticized poly(vinyl chloride).
Lindfors T; Aarnio H; Ivaska A
Anal Chem; 2007 Nov; 79(22):8571-7. PubMed ID: 17929876
[TBL] [Abstract][Full Text] [Related]
12. Ferrocene bound poly(vinyl chloride) as ion to electron transducer in electrochemical ion sensors.
Pawlak M; Grygolowicz-Pawlak E; Bakker E
Anal Chem; 2010 Aug; 82(16):6887-94. PubMed ID: 20666464
[TBL] [Abstract][Full Text] [Related]
13. Fully Inkjet-Printed Paper-Based Potentiometric Ion-Sensing Devices.
Ruecha N; Chailapakul O; Suzuki K; Citterio D
Anal Chem; 2017 Oct; 89(19):10608-10616. PubMed ID: 28849646
[TBL] [Abstract][Full Text] [Related]
14. Carbon Nanotube-Based Ion Selective Sensors for Wearable Applications.
Roy S; David-Pur M; Hanein Y
ACS Appl Mater Interfaces; 2017 Oct; 9(40):35169-35177. PubMed ID: 28925684
[TBL] [Abstract][Full Text] [Related]
15. All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples.
Yuan D; Anthis AH; Ghahraman Afshar M; Pankratova N; Cuartero M; Crespo GA; Bakker E
Anal Chem; 2015 Sep; 87(17):8640-5. PubMed ID: 26272001
[TBL] [Abstract][Full Text] [Related]
16. Simple and disposable potentiometric sensors based on graphene or multi-walled carbon nanotubes--carbon-plastic potentiometric sensors.
Jaworska E; Lewandowski W; Mieczkowski J; Maksymiuk K; Michalska A
Analyst; 2013 Apr; 138(8):2363-71. PubMed ID: 23457707
[TBL] [Abstract][Full Text] [Related]
17. Functionalizing Carbon Substrates with a Covalently Attached Cobalt Redox Buffer for Calibration-Free Solid-Contact Ion-Selective Electrodes.
Kim M; Dong XIN; Spindler BD; Bühlmann P; Stein A
Anal Chem; 2024 May; 96(19):7558-7565. PubMed ID: 38696396
[TBL] [Abstract][Full Text] [Related]
18. A solid-contact Pb(2+)-selective electrode using poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene) as ion-to-electron transducer.
Yu S; Li F; Yin T; Liu Y; Pan D; Qin W
Anal Chim Acta; 2011 Sep; 702(2):195-8. PubMed ID: 21839197
[TBL] [Abstract][Full Text] [Related]
19. Solid-Contact Ion Sensing Without Using an Ion-Selective Membrane through Classic Li-Ion Battery Materials.
Lyu Y; Zhang Y; Xu L; Zhong L; Sun Z; Ma Y; Bao Y; Gan S; Niu L
Anal Chem; 2021 Jun; 93(21):7588-7595. PubMed ID: 34008950
[TBL] [Abstract][Full Text] [Related]
20. Cesium ion-selective electrodes based on 1,3-alternate thiacalix[4]biscrown-6,6.
Choi Y; Kim H; Lee JK; Lee SH; Lim HB; Kim JS
Talanta; 2004 Nov; 64(4):975-80. PubMed ID: 18969699
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]