BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

279 related articles for article (PubMed ID: 28910857)

  • 1. A Guide to Quantitative Biomarker Assay Development using Whispering Gallery Mode Biosensors.
    Robison HM; Bailey RC
    Curr Protoc Chem Biol; 2017 Sep; 9(3):158-173. PubMed ID: 28910857
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Integration of digital microfluidics with whispering-gallery mode sensors for label-free detection of biomolecules.
    Wondimu SF; von der Ecken S; Ahrens R; Freude W; Guber AE; Koos C
    Lab Chip; 2017 May; 17(10):1740-1748. PubMed ID: 28406508
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Whispering gallery mode resonators for rapid label-free biosensing in small volume droplets.
    Wildgen SM; Dunn RC
    Biosensors (Basel); 2015 Mar; 5(1):118-30. PubMed ID: 25806835
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Label-free detection of ovarian cancer biomarkers using whispering gallery mode imaging.
    Huckabay HA; Wildgen SM; Dunn RC
    Biosens Bioelectron; 2013 Jul; 45():223-9. PubMed ID: 23500368
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Attaching biological probes to silica optical biosensors using silane coupling agents.
    Soteropulos CE; Hunt HK
    J Vis Exp; 2012 May; (63):e3866. PubMed ID: 22588224
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Photonic ring resonance is a versatile platform for performing multiplex immunoassays in real time.
    Mudumba S; de Alba S; Romero R; Cherwien C; Wu A; Wang J; Gleeson MA; Iqbal M; Burlingame RW
    J Immunol Methods; 2017 Sep; 448():34-43. PubMed ID: 28527901
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-Time Detection of Staphylococcus Aureus Using Whispering Gallery Mode Optical Microdisks.
    Ghali H; Chibli H; Nadeau JL; Bianucci P; Peter YA
    Biosensors (Basel); 2016 May; 6(2):20. PubMed ID: 27153099
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Integrating a DNA Strand Displacement Reaction with a Whispering Gallery Mode Sensor for Label-Free Mercury (II) Ion Detection.
    Wu F; Wu Y; Niu Z; Vollmer F
    Sensors (Basel); 2016 Jul; 16(8):. PubMed ID: 27483277
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Large-scale parallel surface functionalization of goblet-type whispering gallery mode microcavity arrays for biosensing applications.
    Bog U; Brinkmann F; Kalt H; Koos C; Mappes T; Hirtz M; Fuchs H; Köber S
    Small; 2014 Oct; 10(19):3863-8. PubMed ID: 24990526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fiber-integrated WGM optofluidic chip enhanced by microwave photonic analyzer for cardiac biomarker detection with ultra-high resolution.
    Niu P; Jiang J; Liu K; Wang S; Jing J; Xu T; Wang T; Liu Y; Liu T
    Biosens Bioelectron; 2022 Jul; 208():114238. PubMed ID: 35390720
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Whispering-Gallery Sensors.
    Jiang X; Qavi AJ; Huang SH; Yang L
    Matter; 2020 Aug; 3(2):371-392. PubMed ID: 32835223
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of ZnO Nanorods Based Whispering Gallery Mode Resonator in Optical Immunosensors.
    Tereshchenko A; Yazdi GR; Konup I; Smyntyna V; Khranovskyy V; Yakimova R; Ramanavicius A
    Colloids Surf B Biointerfaces; 2020 Jul; 191():110999. PubMed ID: 32289650
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multiplexed specific label-free detection of NCI-H358 lung cancer cell line lysates with silicon based photonic crystal microcavity biosensors.
    Chakravarty S; Lai WC; Zou Y; Drabkin HA; Gemmill RM; Simon GR; Chin SH; Chen RT
    Biosens Bioelectron; 2013 May; 43():50-5. PubMed ID: 23274197
    [TBL] [Abstract][Full Text] [Related]  

  • 14. From Whispering Gallery Mode Resonators to Biochemical Sensors.
    Loyez M; Adolphson M; Liao J; Yang L
    ACS Sens; 2023 Jul; 8(7):2440-2470. PubMed ID: 37390481
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On-chip label-free biosensing based on active whispering gallery mode resonators pumped by a light-emitting diode.
    Kim Y; Lee H
    Opt Express; 2019 Nov; 27(23):34405-34415. PubMed ID: 31878488
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Detection of Helicobacter hepaticus Using Whispering-Gallery Mode Microcavity Optical Sensors.
    Anderson ME; O'Brien EC; Grayek EN; Hermansen JK; Hunt HK
    Biosensors (Basel); 2015 Aug; 5(3):562-76. PubMed ID: 26262647
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Whispering-gallery-mode biosensing: label-free detection down to single molecules.
    Vollmer F; Arnold S
    Nat Methods; 2008 Jul; 5(7):591-6. PubMed ID: 18587317
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasensitive optofluidic enzyme-linked immunosorbent assay by on-chip integrated polymer whispering-gallery-mode microlaser sensors.
    Ouyang X; Liu T; Zhang Y; He J; He Z; Zhang AP; Tam HY
    Lab Chip; 2020 Jul; 20(14):2438-2446. PubMed ID: 32484485
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PEG Functionalization of Whispering Gallery Mode Optical Microresonator Biosensors to Minimize Non-Specific Adsorption during Targeted, Label-Free Sensing.
    Wang F; Anderson M; Bernards MT; Hunt HK
    Sensors (Basel); 2015 Jul; 15(8):18040-60. PubMed ID: 26213937
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct writing of optical microresonators in a lab-on-a-chip for label-free biosensing.
    Kelemen L; Lepera E; Horváth B; Ormos P; Osellame R; Martínez Vázquez R
    Lab Chip; 2019 Jun; 19(11):1985-1990. PubMed ID: 31044200
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.