BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 28913930)

  • 1. Accuracy, repeatability, and interplatform reproducibility of T
    Bane O; Hectors SJ; Wagner M; Arlinghaus LL; Aryal MP; Cao Y; Chenevert TL; Fennessy F; Huang W; Hylton NM; Kalpathy-Cramer J; Keenan KE; Malyarenko DI; Mulkern RV; Newitt DC; Russek SE; Stupic KF; Tudorica A; Wilmes LJ; Yankeelov TE; Yen YF; Boss MA; Taouli B
    Magn Reson Med; 2018 May; 79(5):2564-2575. PubMed ID: 28913930
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Repeatability and reproducibility of variable flip angle T
    Zhong X; Shakeri S; Liu D; Sayre J; Raman SS; Wu HH; Sung K
    J Magn Reson Imaging; 2019 Jun; 49(6):1730-1735. PubMed ID: 30548513
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization and evaluation of reference region variable flip angle (RR-VFA) B1+ and T
    Rangwala NA; Dregely I; Wu HH; Sung K
    J Magn Reson Imaging; 2017 Mar; 45(3):751-760. PubMed ID: 27532669
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of single reference variable flip angle (SR-VFA) dynamic T
    Malmberg MA; Odéen H; Hofstetter LW; Hadley JR; Parker DL
    Magn Reson Med; 2024 Apr; 91(4):1419-1433. PubMed ID: 38115639
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bias, Repeatability and Reproducibility of Liver T
    Tadimalla S; Wilson DJ; Shelley D; Bainbridge G; Saysell M; Mendichovszky IA; Graves MJ; Guthrie JA; Waterton JC; Parker GJM; Sourbron SP
    J Magn Reson Imaging; 2022 Oct; 56(4):1042-1052. PubMed ID: 35224803
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessing effects of scanner upgrades for clinical studies.
    Keenan KE; Gimbutas Z; Dienstfrey A; Stupic KF
    J Magn Reson Imaging; 2019 Dec; 50(6):1948-1954. PubMed ID: 31111981
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dual flip-angle IR-FLASH with spin history mapping for B1+ corrected T1 mapping: Application to T1 cardiovascular magnetic resonance multitasking.
    Serry FM; Ma S; Mao X; Han F; Xie Y; Han H; Li D; Christodoulou AG
    Magn Reson Med; 2021 Dec; 86(6):3182-3191. PubMed ID: 34309072
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners.
    Raman FS; Kawel-Boehm N; Gai N; Freed M; Han J; Liu CY; Lima JA; Bluemke DA; Liu S
    J Cardiovasc Magn Reson; 2013 Jul; 15(1):64. PubMed ID: 23890156
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla.
    Sung K; Daniel BL; Hargreaves BA
    J Magn Reson Imaging; 2013 Aug; 38(2):454-9. PubMed ID: 23292822
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of T
    Malmberg MA; Odéen H; Parker DL
    Med Phys; 2022 Apr; 49(4):2396-2412. PubMed ID: 35066898
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Repeatability and robustness of MP-GRASP T
    Li Z; Xu X; Yang Y; Feng L
    Magn Reson Med; 2022 May; 87(5):2271-2286. PubMed ID: 34971467
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feasibility of a fast method for B1-inhomogeneity correction for FSPGR sequences.
    van Schie JJ; Lavini C; van Vliet LJ; Vos FM
    Magn Reson Imaging; 2015 Apr; 33(3):312-8. PubMed ID: 25460328
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid multicontrast brain imaging on a 0.35T MR-linac.
    Nejad-Davarani SP; Zakariaei N; Chen Y; Haacke EM; Hurst NJ; Salim Siddiqui M; Schultz LR; Snyder JM; Walbert T; Glide-Hurst CK
    Med Phys; 2020 Sep; 47(9):4064-4076. PubMed ID: 32434276
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a temperature-controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements.
    Jerome NP; Papoutsaki MV; Orton MR; Parkes HG; Winfield JM; Boss MA; Leach MO; deSouza NM; Collins DJ
    Med Phys; 2016 Jun; 43(6):2998-3007. PubMed ID: 27277048
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid high-resolution T
    Li Z; Bilgin A; Johnson K; Galons JP; Vedantham S; Martin DR; Altbach MI
    J Magn Reson Imaging; 2019 Jan; 49(1):239-252. PubMed ID: 30142230
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bloch-Siegert
    Whisenant JG; Dortch RD; Grissom W; Kang H; Arlinghaus LR; Yankeelov TE
    Tomography; 2016 Dec; 2(4):250-259. PubMed ID: 28044146
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of DCE-MRI parametric mapping using MP2RAGE and variable flip angle T1 mapping.
    Bergen RV; Ryner L; Essig M
    Magn Reson Imaging; 2023 Jan; 95():103-109. PubMed ID: 32646633
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Repeatability of T1-quantification in dGEMRIC for three different acquisition techniques: two-dimensional inversion recovery, three-dimensional look locker, and three-dimensional variable flip angle.
    Siversson C; Tiderius CJ; Neuman P; Dahlberg L; Svensson J
    J Magn Reson Imaging; 2010 May; 31(5):1203-9. PubMed ID: 20432357
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determining the longitudinal accuracy and reproducibility of T
    Carr ME; Keenan KE; Rai R; Metcalfe P; Walker A; Holloway L
    J Appl Clin Med Phys; 2021 Nov; 22(11):143-150. PubMed ID: 34562341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. B
    Boudreau M; Tardif CL; Stikov N; Sled JG; Lee W; Pike GB
    J Magn Reson Imaging; 2017 Dec; 46(6):1673-1682. PubMed ID: 28301086
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.