464 related articles for article (PubMed ID: 28915471)
1. Characterization of mechanical properties of pericardium tissue using planar biaxial tension and flexural deformation.
Murdock K; Martin C; Sun W
J Mech Behav Biomed Mater; 2018 Jan; 77():148-156. PubMed ID: 28915471
[TBL] [Abstract][Full Text] [Related]
2. Comparison of tensile properties of xenopericardium from three animal species and finite element analysis for bioprosthetic heart valve tissue.
Rassoli A; Fatouraee N; Guidoin R; Zhang Z
Artif Organs; 2020 Mar; 44(3):278-287. PubMed ID: 31386771
[TBL] [Abstract][Full Text] [Related]
3. A comparative study of different tissue materials for bioprosthetic aortic valves using experimental assays and finite element analysis.
Rassoli A; Fatouraee N; Guidoin R; Zhang Z; Ravaghi S
Comput Methods Programs Biomed; 2022 Jun; 220():106813. PubMed ID: 35461127
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of transcatheter heart valve biomaterials: Computational modeling using bovine and porcine pericardium.
Sulejmani F; Caballero A; Martin C; Pham T; Sun W
J Mech Behav Biomed Mater; 2019 Sep; 97():159-170. PubMed ID: 31125889
[TBL] [Abstract][Full Text] [Related]
5. Functional analysis of bioprosthetic heart valves.
Arcidiacono G; Corvi A; Severi T
J Biomech; 2005 Jul; 38(7):1483-90. PubMed ID: 15922759
[TBL] [Abstract][Full Text] [Related]
6. Dynamic simulation pericardial bioprosthetic heart valve function.
Kim H; Lu J; Sacks MS; Chandran KB
J Biomech Eng; 2006 Oct; 128(5):717-24. PubMed ID: 16995758
[TBL] [Abstract][Full Text] [Related]
7. Characterization of three-dimensional anisotropic heart valve tissue mechanical properties using inverse finite element analysis.
Abbasi M; Barakat MS; Vahidkhah K; Azadani AN
J Mech Behav Biomed Mater; 2016 Sep; 62():33-44. PubMed ID: 27173827
[TBL] [Abstract][Full Text] [Related]
8. The effects of collagen fiber orientation on the flexural properties of pericardial heterograft biomaterials.
Mirnajafi A; Raymer J; Scott MJ; Sacks MS
Biomaterials; 2005 Mar; 26(7):795-804. PubMed ID: 15350785
[TBL] [Abstract][Full Text] [Related]
9. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties.
Martin C; Sun W
Biomech Model Mechanobiol; 2014 Aug; 13(4):759-70. PubMed ID: 24092257
[TBL] [Abstract][Full Text] [Related]
10. Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.
Smuts AN; Blaine DC; Scheffer C; Weich H; Doubell AF; Dellimore KH
J Mech Behav Biomed Mater; 2011 Jan; 4(1):85-98. PubMed ID: 21094482
[TBL] [Abstract][Full Text] [Related]
11. Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.
Sun W; Li K; Sirois E
J Biomech; 2010 Dec; 43(16):3085-90. PubMed ID: 20817163
[TBL] [Abstract][Full Text] [Related]
12. Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves.
Mao J; Rassoli A; Tong Y; Rouse EN; Le-Bel G; How D; Germain L; Fatouraee N; Zhang Z; Reed RR; Guidoin R
Artif Organs; 2019 Oct; 43(10):976-987. PubMed ID: 31140630
[TBL] [Abstract][Full Text] [Related]
13. An experimentally derived stress resultant shell model for heart valve dynamic simulations.
Kim H; Chandran KB; Sacks MS; Lu J
Ann Biomed Eng; 2007 Jan; 35(1):30-44. PubMed ID: 17089074
[TBL] [Abstract][Full Text] [Related]
14. Simulated bioprosthetic heart valve deformation under quasi-static loading.
Sun W; Abad A; Sacks MS
J Biomech Eng; 2005 Nov; 127(6):905-14. PubMed ID: 16438226
[TBL] [Abstract][Full Text] [Related]
15. Simulated thin pericardial bioprosthetic valve leaflet deformation under static pressure-only loading conditions: implications for percutaneous valves.
Li K; Sun W
Ann Biomed Eng; 2010 Aug; 38(8):2690-701. PubMed ID: 20336372
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of transcatheter heart valve biomaterials: Biomechanical characterization of bovine and porcine pericardium.
Caballero A; Sulejmani F; Martin C; Pham T; Sun W
J Mech Behav Biomed Mater; 2017 Nov; 75():486-494. PubMed ID: 28826102
[TBL] [Abstract][Full Text] [Related]
17. Structural Model for Viscoelastic Properties of Pericardial Bioprosthetic Valves.
Rassoli A; Fatouraee N; Guidoin R
Artif Organs; 2018 Jun; 42(6):630-639. PubMed ID: 29602267
[TBL] [Abstract][Full Text] [Related]
18. Planar biaxial testing of heart valve cusp replacement biomaterials: Experiments, theory and material constants.
Labrosse MR; Jafar R; Ngu J; Boodhwani M
Acta Biomater; 2016 Nov; 45():303-320. PubMed ID: 27570204
[TBL] [Abstract][Full Text] [Related]
19. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.
Abbasi M; Azadani AN
J Biomech; 2015 Oct; 48(13):3663-71. PubMed ID: 26338100
[TBL] [Abstract][Full Text] [Related]
20. Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents.
Krucinski S; Vesely I; Dokainish MA; Campbell G
J Biomech; 1993 Aug; 26(8):929-43. PubMed ID: 8349718
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]