BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 28920236)

  • 1. Are we really doing better with Hem-o-lok in VATS?
    Lv X; Wang Z; Cha Y; Hu J; Rusidanmu A; He Z
    Thorac Cancer; 2013 Aug; 4(3):335-338. PubMed ID: 28920236
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ligation of uterine vessels in total laparoscopic hysterectomy using Hem-o-lok clips.
    Lee JE; Kim KG; Lee DO; Seo SS; Kang S; Park SY; Lim MC
    Taiwan J Obstet Gynecol; 2015 Feb; 54(1):8-12. PubMed ID: 25675912
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a commercial vascular clip: risk factors and predictors of failure from in vitro studies.
    Sooriakumaran P; Kommu SS; Cooke J; Gordon S; Brown C; Eddy B; Rimington PD; Rane A
    BJU Int; 2009 May; 103(10):1410-2. PubMed ID: 19021622
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Routine vascular control using the Hem-o-lok clip in laparoscopic nephrectomy: animal study and clinical application.
    Yip SK; Tan YH; Cheng C; Sim HG; Lee YM; Chee C
    J Endourol; 2004 Feb; 18(1):77-81. PubMed ID: 15006060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hilar closure using staplers or Hem-o-lok clips in a rabbit model.
    Smith AL; Mayhew PD; Soares JH; Kass PH; Brosnan RJ
    J Surg Res; 2014 Dec; 192(2):616-20. PubMed ID: 25167784
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental Studies of Nonabsorbable Polymeric Surgical Clips for Use in Urologic Laparoscopy.
    Saki Z; Kallidonis P; Noureldin Y; Kotsiris D; Ntasiotis P; Adamou C; Vagionis A; Liatsikos E
    J Endourol; 2019 Sep; 33(9):730-735. PubMed ID: 31266362
    [No Abstract]   [Full Text] [Related]  

  • 7. Clinical research of renal vein control using Hem-o-lok clips in laparoscopic nephrectomy.
    Izaki H; Fukumori T; Takahashi M; Nakatsuji H; Oka N; Taue R; Nishitani MA; Kanayama HO
    Int J Urol; 2006 Aug; 13(8):1147-9. PubMed ID: 16903952
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Vascular clips are safe and a great cost-effective technique for arterial and venous control in laparoscopic nephrectomy: single-center experience with 1834 laparoscopic nephrectomies.
    Simforoosh N; Sarhangnejad R; Basiri A; Ziaee SA; Sharifiaghdas F; Tabibi A; Nouralizadeh A; Kashi AH; Moosanejad N
    J Endourol; 2012 Aug; 26(8):1009-12. PubMed ID: 22332818
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Failure of Hem-o-lok clips used on a renal artery after laparoscopic renal surgery.
    Yanagi M; Hamasaki T; Shimizu H; Kimata R; Takeda H; Akatsuka J; Endo Y; Hayashi T; Kondo Y
    J Med Invest; 2021; 68(3.4):393-395. PubMed ID: 34759167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Hem-o-lok clip is safe for laparoscopic nephrectomy: a multi-institutional review.
    Ponsky L; Cherullo E; Moinzadeh A; Desai M; Kaouk J; Haber GP; Chen D; Ng C; Fuchs G; Singh D; Finelli A; Frank I; Matin S
    Urology; 2008 Apr; 71(4):593-6. PubMed ID: 18295866
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of holding strength of suture anchors on human renal capsule.
    Tarin T; Kimm S; Chung B; Shinghal R; Reese J
    J Endourol; 2010 Feb; 24(2):293-7. PubMed ID: 20050785
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of the Hem-o-lok ligation system in laparoscopic nephrectomy.
    Ping H; Xing NZ; Zhang JH; Yan Y; Kang N; Niu YN
    Surg Endosc; 2010 Jun; 24(6):1494-7. PubMed ID: 20033713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polymeric locking clips [Hem-o-lok] versus Metallic clips in elective Laparoscopic Cholecystectomy: A Retrospective study of 1496 patients.
    Madhavan S; Pandey A; Masood S; Kumar S; Chauhan S; Kumar D; Jha S
    Pol Przegl Chir; 2021 Apr; 93(3):1-5. PubMed ID: 33949331
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Absolok® versus Hem-o-Lok® clips for renorrhaphy during partial nephrectomy for parenchymal renal tumors.
    Rossanese M; Crestani A; Giannarini G; Calandriello M; Alario G; Simonato A; Ficarra V
    Minerva Urol Nefrol; 2020 Feb; 72(1):91-98. PubMed ID: 31833724
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reported failures of the polymer self-locking (Hem-o-lok) clip: review of data from the Food and Drug Administration.
    Meng MV
    J Endourol; 2006 Dec; 20(12):1054-7. PubMed ID: 17206901
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the Ti-knot device and Hem-o-lok clips with other devices commonly used for laparoscopic renal-artery ligation.
    Joseph J; Leung YY; Eichel L; Scheidweiler K; Erturk E; Wood R
    J Endourol; 2004 Mar; 18(2):163-6. PubMed ID: 15072624
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hem-o-lok clip migration to duodenal bulb post-cholecystectomy: A case report.
    Liu HY; Yin AH; Wei Z
    World J Gastrointest Surg; 2024 May; 16(5):1461-1466. PubMed ID: 38817275
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of a single Hem-o-lok clip in securing the base of the appendix during laparoscopic appendectomy.
    Delibegović S
    J Laparoendosc Adv Surg Tech A; 2012; 22(1):85-7. PubMed ID: 22145605
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraneobladder Hem-o-Lok Migration with Stone Formation after Orthotopic Neobladder Cystectomy.
    Shu-Xiong Z; Zhen-Sheng Z; Xiao-Wen Y; Hui-Zhen L; Xin L; Ying-Hao S; Chuan-Liang X
    Case Rep Urol; 2014; 2014():872989. PubMed ID: 25436169
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transmural migration of azygous vein Hem-O-lok clip causing food bolus 3 months following uneventful minimally invasive oesophagectomy.
    Kordzadeh A; Charalabopoulos A; Lorenzi B
    Acta Chir Belg; 2018 Aug; 118(4):270-271. PubMed ID: 29969952
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.