These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 28922125)

  • 1. Efficiency Enhancement for an Inductive Wireless Power Transfer System by Optimizing the Impedance Matching Networks.
    Miao Z; Liu D; Gong C
    IEEE Trans Biomed Circuits Syst; 2017 Oct; 11(5):1160-1170. PubMed ID: 28922125
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An Adaptive Impedance Matching Network with Closed Loop Control Algorithm for Inductive Wireless Power Transfer.
    Miao Z; Liu D; Gong C
    Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28763011
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impedance matching wireless power transmission system for biomedical devices.
    Lum KY; Lindén M; Tan TS
    Stud Health Technol Inform; 2015; 211():225-32. PubMed ID: 25980873
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A low-frequency versatile wireless power transfer technology for biomedical implants.
    Jiang H; Zhang J; Lan D; Chao ; Liou S; Shahnasser H; Fechter R; Hirose S; Harrison M; Roy S
    IEEE Trans Biomed Circuits Syst; 2013 Aug; 7(4):526-35. PubMed ID: 23893211
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficiency optimization of class-D biomedical inductive wireless power transfer systems by means of frequency adjustment.
    Schormans M; Valente V; Demosthenous A
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():5473-6. PubMed ID: 26737530
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Maximum achievable efficiency in near-field coupled power-transfer systems.
    Zargham M; Gulak PG
    IEEE Trans Biomed Circuits Syst; 2012 Jun; 6(3):228-45. PubMed ID: 23853145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inductive and ultrasonic multi-tier interface for low-power, deeply implantable medical devices.
    Sanni A; Vilches A; Toumazou C
    IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):297-308. PubMed ID: 23853174
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous Power Feedback and Maximum Efficiency Point Tracking for Miniaturized RF Wireless Power Transfer Systems.
    Stoecklin S; Yousaf A; Gidion G; Reindl L; Rupitsch SJ
    Sensors (Basel); 2021 Mar; 21(6):. PubMed ID: 33809337
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial.
    Schormans M; Valente V; Demosthenous A
    IEEE Trans Biomed Circuits Syst; 2018 Oct; 12(5):1112-1130. PubMed ID: 30010596
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design of Tunable Ultrasonic Receivers for Efficient Powering of Implantable Medical Devices With Reconfigurable Power Loads.
    Chang TC; Weber MJ; Wang ML; Charthad J; Khuri-Yakub BP; Arbabian A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Oct; 63(10):1554-1562. PubMed ID: 27623580
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimal wireless receiver structure for omnidirectional inductive power transmission to biomedical implants.
    Gougheri HS; Kiani M
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():1975-1978. PubMed ID: 28268716
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safe inductive power transmission to millimeter-sized implantable microelectronics devices.
    Ibrahim A; Kiani M
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():817-20. PubMed ID: 26736387
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhanced-efficiency Capacitive Coupling Intra-body Power Transfer Systems with 1.8 V Output for Neural Interfaces.
    Han C; Lin C; Mao J; Yu S; Zhang Z
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38083244
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wireless Pacing Using an Asynchronous Three-Tiered Inductive Power Transfer System.
    Abiri P; Abiri A; Gudapati V; Chang CC; Roustaei M; Bourenane H; Anwar U; Markovic D; Hsiai TK
    Ann Biomed Eng; 2020 Apr; 48(4):1368-1381. PubMed ID: 31974869
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Robust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants.
    Mirbozorgi SA; Yeon P; Ghovanloo M
    IEEE Trans Biomed Circuits Syst; 2017 Jun; 11(3):692-702. PubMed ID: 28504947
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An NFC on Two-Coil WPT Link for Implantable Biomedical Sensors under Ultra-Weak Coupling.
    Gong C; Liu D; Miao Z; Wang W; Li M
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28604610
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Linear-Power-Regulated Wireless Power Transfer Method for Decreasing the Heat Dissipation of Fully Implantable Microsystems.
    Wang H; Zhu C; Jin W; Tang J; Wu Z; Chen K; Hong H
    Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433362
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modeling and Optimization of Class-E Amplifier at Subnominal Condition in a Wireless Power Transfer System for Biomedical Implants.
    Liu H; Shao Q; Fang X
    IEEE Trans Biomed Circuits Syst; 2017 Feb; 11(1):35-43. PubMed ID: 27323372
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A high-power versatile wireless power transfer for biomedical implants.
    Jiang H; Zhang JM; Liou SS; Fechter R; Hirose S; Harrison M; Roy S
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6437-40. PubMed ID: 21096712
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An Energy-Efficient Antenna Impedance Detection Using Electrical Balance for Single-Step On-Chip Tunable Matching in Wearable/Implantable Applications.
    Song M; Lu C; Ba A; Wang X; Liu YH; Shibata K; Bachmann C; Philips K
    IEEE Trans Biomed Circuits Syst; 2017 Dec; 11(6):1236-1244. PubMed ID: 29293421
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.