191 related articles for article (PubMed ID: 28922709)
21. Topically Applied Epsilon-Aminocaproic Acid Reduces Blood Loss and Length of Hospital Stay After Total Knee Arthroplasty.
Harper RA; Sucher MG; Giordani M; Nedopil AJ
Orthopedics; 2017 Nov; 40(6):e1044-e1049. PubMed ID: 28968480
[TBL] [Abstract][Full Text] [Related]
22. After early release of tourniquet in total knee arthroplasty, should it be reinflated or kept deflated? A randomized trial.
Na YG; Bamne AB; Won HH; Kim TK
Knee Surg Sports Traumatol Arthrosc; 2017 Sep; 25(9):2769-2777. PubMed ID: 26215773
[TBL] [Abstract][Full Text] [Related]
23. The limited use of a tourniquet during total knee arthroplasty: a randomized controlled trial.
Fan Y; Jin J; Sun Z; Li W; Lin J; Weng X; Qiu G
Knee; 2014 Dec; 21(6):1263-8. PubMed ID: 25212990
[TBL] [Abstract][Full Text] [Related]
24. The timing of tourniquet release and 'retransfusion' drains in total knee arthroplasty: A stratified randomised pilot investigation.
Dutton T; De-Souza R; Parsons N; Costa ML
Knee; 2012 Jun; 19(3):190-2. PubMed ID: 21440444
[TBL] [Abstract][Full Text] [Related]
25. Closed Suction Drainage Is Not Associated with Faster Recovery after Total Knee Arthroplasty: A Prospective Randomized Controlled Study of 80 Patients.
Wang D; Xu J; Zeng WN; Zhou K; Xie TH; Chen Z; Yu HD; Li JL; Zhou ZK; Pei FX
Orthop Surg; 2016 May; 8(2):226-33. PubMed ID: 27384732
[TBL] [Abstract][Full Text] [Related]
26. Closed Suction Drainage after Primary Total Knee Arthroplasty: A Prospective Randomized Trial.
Erne F; Wetzel S; Wülker N; Gesicki M; Hofmann UK
J Knee Surg; 2018 Sep; 31(8):804-810. PubMed ID: 29294497
[TBL] [Abstract][Full Text] [Related]
27. Is lower tourniquet pressure during total knee arthroplasty effective? A prospective randomized controlled trial.
Kim TK; Bamne AB; Sim JA; Park JH; Na YG
BMC Musculoskelet Disord; 2019 Jun; 20(1):275. PubMed ID: 31159799
[TBL] [Abstract][Full Text] [Related]
28. Scalpel can achieve better clinical outcomes compared with electric cautery in primary total knee arthroplasty: a comparison study.
Lin W; Dai Y; Niu J; Yang G; Li M; Wang F
BMC Musculoskelet Disord; 2020 Jun; 21(1):409. PubMed ID: 32600294
[TBL] [Abstract][Full Text] [Related]
29. Tourniquet and closed-suction drains in total knee arthroplasty. No beneficial effects on bleeding management and knee function at a higher cost.
Yin D; Delisle J; Banica A; Senay A; Ranger P; Laflamme GY; Jun J; Fernandes J
Orthop Traumatol Surg Res; 2017 Jun; 103(4):583-589. PubMed ID: 28330800
[TBL] [Abstract][Full Text] [Related]
30. The effect of tourniquet use on hidden blood loss in total knee arthroplasty.
Li B; Wen Y; Wu H; Qian Q; Lin X; Zhao H
Int Orthop; 2009 Oct; 33(5):1263-8. PubMed ID: 18751703
[TBL] [Abstract][Full Text] [Related]
31. Computer assisted versus conventional total knee replacement: a comparison of tourniquet time, blood loss and length of stay.
Ajwani SH; Jones M; Jarratt JW; Shepard GJ; Ryan WG
Knee; 2012 Oct; 19(5):606-10. PubMed ID: 22197632
[TBL] [Abstract][Full Text] [Related]
32. The effect of tourniquet usage on cement penetration in total knee arthroplasty: A prospective randomized study of 3 methods.
Ozkunt O; Sariyilmaz K; Gemalmaz HC; Dikici F
Medicine (Baltimore); 2018 Jan; 97(4):e9668. PubMed ID: 29369184
[TBL] [Abstract][Full Text] [Related]
33. Prospective randomised trial comparing unlinked, modular bicompartmental knee arthroplasty and total knee arthroplasty: a five years follow-up.
Yeo NE; Chen JY; Yew A; Chia SL; Lo NN; Yeo SJ
Knee; 2015 Sep; 22(4):321-7. PubMed ID: 25956739
[TBL] [Abstract][Full Text] [Related]
34. Comparison of three different tourniquet application strategies for minimally invasive total knee arthroplasty: a prospective non-randomized clinical trial.
Huang ZY; Pei FX; Ma J; Yang J; Zhou ZK; Kang PD; Shen B
Arch Orthop Trauma Surg; 2014 Apr; 134(4):561-70. PubMed ID: 24515866
[TBL] [Abstract][Full Text] [Related]
35. A comparative analysis of the role of Tranexamic acid as an independent variable in reducing intraoperative blood loss in patients undergoing conventional total knee arthroplasty versus computer-assisted total knee arthroplasty.
Eachempati KK; Gurava Reddy AV; Apsingi S; Sankineani SR; Shaheed J; Dannana C
Musculoskelet Surg; 2017 Dec; 101(3):255-259. PubMed ID: 28470576
[TBL] [Abstract][Full Text] [Related]
36. Early Removal of Drainage Tube after Fast-Track Primary Total Knee Arthroplasty.
Zhang S; Xu B; Huang Q; Yao H; Xie J; Pei F
J Knee Surg; 2017 Jul; 30(6):571-576. PubMed ID: 27776372
[TBL] [Abstract][Full Text] [Related]
37. Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial.
Stetzelberger V; Obertacke U; Jawhar A
Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1728-1736. PubMed ID: 29058023
[TBL] [Abstract][Full Text] [Related]
38. Effects of different methods of using pneumatic tourniquet in patients undergoing total knee arthroplasty: a randomized control trial.
Zhang Y; Li D; Liu P; Wang X; Li M
Ir J Med Sci; 2017 Nov; 186(4):953-959. PubMed ID: 28260153
[TBL] [Abstract][Full Text] [Related]
39. Electric cautery does not reduce blood loss in primary total knee arthroplasty compared with scalpel only surgery a double-blinded randomized controlled trial.
Tammachote N; Kanitnate S
Int Orthop; 2018 Dec; 42(12):2755-2760. PubMed ID: 29968137
[TBL] [Abstract][Full Text] [Related]
40. No effect of tourniquet in primary total knee arthroplasty on muscle strength, functional outcome, patient satisfaction and health status: a randomized clinical trial.
Jawhar A; Skeirek D; Stetzelberger V; Kollowa K; Obertacke U
Knee Surg Sports Traumatol Arthrosc; 2020 Apr; 28(4):1045-1054. PubMed ID: 31372679
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]