These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

252 related articles for article (PubMed ID: 28926354)

  • 1. Neointimal coverage of jailed side branches in coronary bifurcation lesions: an optical coherence tomography analysis.
    Kume T; Yamada R; Terumasa K; Tamada T; Imai K; Fukuhara K; Goryo Y; Kawamura A; Hiroshi O; Neishi Y; Uemura S
    Coron Artery Dis; 2018 Mar; 29(2):114-118. PubMed ID: 28926354
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relationship between neointimal strut bridge and jailed side-branch ostial area.
    Wu X; You W; Wu Z; Ye F; Chen S
    Herz; 2021 Mar; 46(2):178-187. PubMed ID: 31555892
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Serial changes in the three-dimensional aspect of the side-branch ostium jailed by a drug-eluting stent assessed by optical coherence tomography.
    Nakamura T; Okamura T; Fujimura T; Yamada J; Nao T; Tateishi H; Maeda T; Oda T; Shiraishi K; Nakashima T; Nishimura S; Miura T; Matsuzaki M; Yano M
    Int J Cardiovasc Imaging; 2017 Jun; 33(6):797-806. PubMed ID: 28168562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of the proximal optimization technique on crossover stenting in coronary bifurcation lesions in the 3D-OCT bifurcation registry.
    Murasato Y; Mori T; Okamura T; Nagoshi R; Fujimura T; Yamawaki M; Ono S; Serikawa T; Nakao F; Shite J;
    Int J Cardiovasc Imaging; 2019 Jun; 35(6):981-990. PubMed ID: 30887408
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging: The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months).
    Chevalier B; Smits PC; Carrié D; Mehilli J; Van Boven AJ; Regar E; Sawaya FJ; Chamié D; Kraaijeveld AO; Hovasse T; Vlachojannis GJ
    Circ Cardiovasc Interv; 2017 Dec; 10(12):. PubMed ID: 29246909
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Very early tissue coverage after drug-eluting stent implantation: an optical coherence tomography study.
    Takahara M; Kitahara H; Nishi T; Miura K; Miyayama T; Sugimoto K; Nakayama T; Fujimoto Y; Kobayashi Y
    Int J Cardiovasc Imaging; 2017 Jan; 33(1):25-30. PubMed ID: 27601229
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of Early Healing Profile and Neointimal Transformation Over 24 Months Using Longitudinal Sequential Optical Coherence Tomography Assessments and 3-Year Clinical Results of the New Dual-Therapy Endothelial Progenitor Cell Capturing Sirolimus-Eluting Combo Stent: The EGO-Combo Study.
    Lee SW; Lam SC; Tam FC; Chan KK; Shea CP; Kong SL; Wong AY; Yung A; Zhang LW; Tse HF; Wu KK; Chan R; Haude M; Mehran R; Mintz GS; Maehara A
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27418609
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neointimal response to everolimus-eluting bioresorbable scaffolds implanted at bifurcating coronary segments: insights from optical coherence tomography.
    Sato T; Jose J; El-Mawardy M; Sulimov DS; Tölg R; Richardt G; Abdel-Wahab M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):169-175. PubMed ID: 27757563
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term invasive follow-up of bioresorbable vascular scaffold: Optical Coherence Tomography assessment of jailed side branches.
    Paradies V; Smits PC; Vachojannis GJ; Royaards KJ; Wassing J; van der Ent M
    Cardiovasc Revasc Med; 2018 Apr; 19(3 Pt A):279-285. PubMed ID: 29066339
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.
    Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of final kissing balloon inflation on vessel healing following drug-eluting stent implantation: Insight from the optical coherence tomography sub-study of the J-REVERSE trial.
    Takahashi H; Otake H; Shinke T; Murasato Y; Kinoshita Y; Yamawaki M; Takeda Y; Fujii K; Yamada SI; Shimada Y; Yamashita T; Yumoto K; Hirata KI
    J Cardiol; 2016 Dec; 68(6):504-511. PubMed ID: 26899277
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion after Provisional Stenting of Coronary Bifurcation Lesions.
    Cao Y; Mintz GS; Matsumura M; Zhang W; Lin Y; Wang X; Fujino A; Lee T; Murai T; Hoshino M; Usui E; Kanaji Y; Yonetsu T; Kakuta T; Maehara A
    Cardiovasc Revasc Med; 2019 Nov; 20(11):1007-1013. PubMed ID: 30683562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of branching angle on neointimal coverage of drug-eluting stents implanted in bifurcation lesions.
    Watanabe M; Uemura S; Kita Y; Sugawara Y; Goryo Y; Ueda T; Soeda T; Okayama S; Okura H; Kume T; Saito Y
    Coron Artery Dis; 2016 Dec; 27(8):682-689. PubMed ID: 27525716
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Success rate and influencing factors of a balloon-push technique: A new technique to remove side branch-jailed struts under three-dimensional optical coherence tomography guidance.
    Nagoshi R; Kijima Y; Kozuki A; Fujiwara R; Shibata H; Suzuki A; Soga F; Asada H; Higuchi K; Shite J
    Catheter Cardiovasc Interv; 2023 Feb; 101(3):528-535. PubMed ID: 36617385
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two-week interval optical coherence tomography: imaging evidence on neointimal coverage completion after implantation of the Endeavor zotarolimus-eluting stent.
    Nishinari M; Shimohama T; Tojo T; Shiono T; Shinagawa H; Kameda R; Aoyama N; Izumi T
    Catheter Cardiovasc Interv; 2013 Dec; 82(7):E871-8. PubMed ID: 23873677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study.
    Hashikata T; Tojo T; Namba S; Kitasato L; Hashimoto T; Kameda R; Shimohama T; Yamaoka-Tojo M; Ako J
    Heart Vessels; 2016 Feb; 31(2):206-11. PubMed ID: 25362579
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography.
    Li S; Gai L; Yang T; Zhang L; Xu X; Bai Q; Xu H; Wang Y
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):768-75. PubMed ID: 22639418
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coronary bifurcation bench test using multimodality imaging: Impact of stent strut link location on stent deformity and jailed side-branch orifices during re-proximal optimizing technique.
    Kume T; Yamada R; Koyama T; Tamada T; Imai K; Fukuhara K; Goryo Y; Kawamura A; Okamoto H; Neishi Y; Uemura S
    Catheter Cardiovasc Interv; 2019 Jan; 93(1):E17-E23. PubMed ID: 30244506
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Protection of side-branch ostium by the jailed balloon technique validated by three-dimensional optical coherence tomography].
    Cui JG; Jin QH; Wu X; Yang X; Qian G; Chen YD
    Zhonghua Xin Xue Guan Bing Za Zhi; 2023 Feb; 51(2):136-142. PubMed ID: 36789592
    [No Abstract]   [Full Text] [Related]  

  • 20. Ex vivo assessment of neointimal characteristics after drug-eluting stent implantation: Optical coherence tomography and histopathology validation study.
    Imanaka T; Fujii K; Hao H; Shibuya M; Saita T; Kawakami R; Fukunaga M; Kawai K; Tamaru H; Miki K; Horimatsu T; Sumiyoshi A; Nishimura M; Hirota S; Masuyama T; Ishihara M
    Int J Cardiol; 2016 Oct; 221():1043-7. PubMed ID: 27447812
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.