These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 28928803)

  • 1. 64-Slice spiral double-low CT to evaluate the degree of stenosis and plaque composition in diagnosing coronary artery disease.
    Feng XR; Liang LH; Wu JF; Chen YQ; Liang S
    Exp Ther Med; 2017 Oct; 14(4):3088-3092. PubMed ID: 28928803
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Researching the character and stenosis of coronary calcified plaques by using 16-slice spiral CT].
    Hu XH; Zhang SZ; Huang WX; Zhang QW; Wang D
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2006 Feb; 28(1):40-3. PubMed ID: 16548186
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of 64-slice Spiral CT in coronary artery imaging.
    Wang J
    J Pak Med Assoc; 2020 Sep; 70 [Special Issue](9):2-8. PubMed ID: 33177721
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Comparison of coronary angiography between 64-slice and 16-slice spiral CT].
    Wang YN; Jin ZY; Kong LY; Zhang ZH; Song L; Zhang SY; Zhang LR; Lin SB; Wang Y; Zhao WM
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2006 Feb; 28(1):26-31. PubMed ID: 16548183
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of heart rate on the diagnostic accuracy of 256-slice computed tomography angiography in the detection of coronary artery stenosis: ROC curve analysis.
    Wang G; Wu Y; Zhang Z; Zheng X; Zhang Y; Liang M; Yuan H; Shen H; Li D
    Exp Ther Med; 2016 May; 11(5):1937-1942. PubMed ID: 27168831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic accuracy of 320-slice computed-tomography for detection of significant coronary artery stenosis in patients with various heart rates and heart rhythms compared with conventional coronary-angiography.
    Uehara M; Takaoka H; Kobayashi Y; Funabashi N
    Int J Cardiol; 2013 Aug; 167(3):809-15. PubMed ID: 22429616
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The value of 64-slice spiral computed tomography (MSCT) coronary angiography in patients with coronary heart disease].
    Zheng SS; Zhou Y; Chen J; Liu B
    Zhonghua Yi Xue Za Zhi; 2007 May; 87(20):1427-9. PubMed ID: 17785071
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Value and limitations of multislice spiral CT in diagnosing coronary artery stenoses].
    Wang ZQ; Zhu H; Zhou XC; Yang ZQ; Jia CF; Sun XX; Wang HY
    Zhonghua Xin Xue Guan Bing Za Zhi; 2008 Nov; 36(11):989-93. PubMed ID: 19102911
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnosis of carotid artery disease: preliminary experience with maximum-intensity-projection spiral CT angiography.
    Marks MP; Napel S; Jordan JE; Enzmann DR
    AJR Am J Roentgenol; 1993 Jun; 160(6):1267-71. PubMed ID: 8498231
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound.
    Leber AW; Knez A; von Ziegler F; Becker A; Nikolaou K; Paul S; Wintersperger B; Reiser M; Becker CR; Steinbeck G; Boekstegers P
    J Am Coll Cardiol; 2005 Jul; 46(1):147-54. PubMed ID: 15992649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Coronary angiography with sixteen-slice spiral CT: an initial study].
    Jin ZY; Zhang ZH; Lin SB; Li DJ; Lu JJ; You H; Wang Y; Wang LH; Zhao WM; Mou WB; Zhang LR; Zhu WL; Zhag SY; Ni C; Jia N; Ren H; Yu HQ; Miao Q; Fang Q
    Zhonghua Yi Xue Za Zhi; 2003 Jul; 83(13):1150-5. PubMed ID: 12921634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Qualitative and quantitative diagnostic performance of 320-slice computed tomography for detecting coronary artery disease with respect to atherosclerotic plaque characteristics].
    Li S; Liu J; Peng L; Dong R; Wu H; Wang C; Ni Q; Luo Y; Zhu J; Chen L
    Zhonghua Yi Xue Za Zhi; 2014 Oct; 94(39):3071-4. PubMed ID: 25549680
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison between coronary plaque 64-slice spiral CT characteristics and risk factors of coronary artery disease patients in Chinese Han population and Mongolian.
    Bai Z; Yang X; Han X; Dong P; Liu A
    Pak J Med Sci; 2013 Jul; 29(4):933-7. PubMed ID: 24353662
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: assessment of cross-sectional and longitudinal vessel reconstructions.
    Cury RC; Ferencik M; Achenbach S; Pomerantsev E; Nieman K; Moselewski F; Abbara S; Jang IK; Brady TJ; Hoffmann U
    Eur J Radiol; 2006 Mar; 57(3):345-50. PubMed ID: 16442256
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Noninvasive detection of coronary artery stenosis using 16-slice spiral CT: a comparison with selective X-ray coronary angiography.
    Shi H; Han P; Kong X; Feng G; Hoffmann MH
    J Huazhong Univ Sci Technolog Med Sci; 2006; 26(3):338-40. PubMed ID: 16961287
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Clinical application of 16-slice spiral CT coronary angiography].
    Xu SW; Zhang XL; Zeng JH; Wang JY; Li TR; Qian GN; Gao RG
    Di Yi Jun Yi Da Xue Xue Bao; 2005 Feb; 25(2):218-22. PubMed ID: 15699011
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Synchrotron radiation computed tomography assessment of calcified plaques and coronary stenosis with different slice thicknesses and beam energies on 3D printed coronary models.
    Sun Z; Ng CKC; Squelch A
    Quant Imaging Med Surg; 2019 Jan; 9(1):6-22. PubMed ID: 30788242
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Non-invasive imaging of coronary artery with 16-slice spiral computed tomography.
    Zhang ZH; Jin ZY; Li DJ; Lin SB; Zhang SY; Kong LY; Wang Y; Wang LH; Zhao WM; Mou WB; Zhang LR; Zhu WL; Ni C; Ren H; Yu HQ; Miao Q; Fang Q
    Chin Med Sci J; 2004 Sep; 19(3):174-9. PubMed ID: 15506642
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of calcification on diagnostic accuracy of 64-slice spiral computed tomography for detecting coronary artery disease: a single center experience.
    Nazeri I; Shahabi P; Tehrai M; Sharif-Kashani B; Nazeri A
    Arch Iran Med; 2010 Sep; 13(5):373-83. PubMed ID: 20804303
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Clinical application of 64-slice CT angiography in the evaluation of lumen before and after coronary artery stent implantation].
    Ma E; Yang Z; Feng Y; Zhang L; He Y; Guo Y; Qian L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Dec; 25(6):1311-4, 1318. PubMed ID: 19166199
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.