  • 21. Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial.
    Xu B; Zhang YJ; Sun ZW; Qiao SB; Chen SL; Zhang RY; Pan DR; Pang S; Zhang Q; Xu L; Yang YJ; Leon MB; Gao RL
    Int J Cardiovasc Imaging; 2015 Dec; 31(8):1489-96. PubMed ID: 26208685
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optical coherence tomography tissue coverage and characterization at six months after implantation of bioresorbable scaffolds versus conventional everolimus eluting stents in the ISAR-Absorb MI trial.
    Rai H; Alfonso F; Maeng M; Bradaric C; Wiebe J; Cuesta J; Christiansen EH; Cassese S; Hoppmann P; Colleran R; Harzer F; Bresha J; Nano N; Schneider S; Laugwitz KL; Joner M; Kastrati A; Byrne RA
    Int J Cardiovasc Imaging; 2021 Oct; 37(10):2815-2826. PubMed ID: 34420177
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis.
    Jaguszewski M; Aloysius R; Wang W; Bezerra HG; Hill J; De Winter RJ; Karjalainen PP; Verheye S; Wijns W; Lüscher TF; Joner M; Costa M; Landmesser U
    JACC Cardiovasc Interv; 2017 Mar; 10(5):489-499. PubMed ID: 28279316
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Second generation, sirolimus-eluting, bioresorbable Tyrocore scaffold implantation in patients with ST-segment elevation myocardial infarction: Baseline OCT and 30-day clinical outcomes - A FANTOM STEMI pilot study.
    Koltowski L; Tomaniak M; Ochijewicz D; Maksym J; Roleder T; Zaleska M; Proniewska K; Opolski G; Kochman J
    Catheter Cardiovasc Interv; 2020 Jul; 96(1):E1-E7. PubMed ID: 31343827
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.
    Alfonso F; Pérez-Vizcayno MJ; García Del Blanco B; Otaegui I; Masotti M; Zueco J; Veláquez M; Sanchís J; García-Touchard A; Lázaro-García R; Moreu J; Bethencourt A; Cuesta J; Rivero F; Cárdenas A; Gonzalo N; Jiménez-Quevedo P; Fernández C;
    JACC Cardiovasc Interv; 2016 Jun; 9(12):1246-1255. PubMed ID: 27339840
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction: rationale and design of the randomised TROFI II study.
    Räber L; Onuma Y; Brugaletta S; Garcia-Garcia HM; Backx B; Iñiguez A; Okkels Jensen L; Cequier-Fillat À; Pilgrim T; Christiansen EH; Hofma SH; Suttorp M; Serruys PW; Sabaté M; Windecker S
    EuroIntervention; 2016 Jul; 12(4):482-9. PubMed ID: 26342471
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial.
    Onuma Y; Dudek D; Thuesen L; Webster M; Nieman K; Garcia-Garcia HM; Ormiston JA; Serruys PW
    JACC Cardiovasc Interv; 2013 Oct; 6(10):999-1009. PubMed ID: 24156961
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Incidence and short-term clinical outcomes of small side branch occlusion after implantation of an everolimus-eluting bioresorbable vascular scaffold: an interim report of 435 patients in the ABSORB-EXTEND single-arm trial in comparison with an everolimus-eluting metallic stent in the SPIRIT first and II trials.
    Muramatsu T; Onuma Y; García-García HM; Farooq V; Bourantas CV; Morel MA; Li X; Veldhof S; Bartorelli A; Whitbourn R; Abizaid A; Serruys PW;
    JACC Cardiovasc Interv; 2013 Mar; 6(3):247-57. PubMed ID: 23517836
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging.
    Kobayashi N; Ito Y; Yamawaki M; Araki M; Sakai T; Sakamoto Y; Mori S; Tsutsumi M; Nauchi M; Honda Y; Tokuda T; Makino K; Shirai S; Hirano K
    Int J Cardiovasc Imaging; 2018 Apr; 34(4):515-522. PubMed ID: 29159531
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Optical coherence tomography findings after chronic total occlusion interventions: Insights from the "AngiographiC evaluation of the everolimus-eluting stent in chronic Total occlusions" (ACE-CTO) study (NCT01012869).
    Sherbet DP; Christopoulos G; Karatasakis A; Danek BA; Kotsia A; Navara R; Michael TT; Roesle M; Rangan BV; Haagen D; Garcia S; Maniu C; Pershad A; Abdullah SM; Hastings JL; Kumbhani DJ; Luna M; Addo T; Banerjee S; Brilakis ES
    Cardiovasc Revasc Med; 2016; 17(7):444-449. PubMed ID: 27133499
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients.
    Roguin A; Kandzari DE; Marcusohn E; Koolen JJ; Doros G; Massaro JM; Garcia-Garcia HM; Bennett J; Gharib EG; Cutlip DE; Waksman R
    Circ Cardiovasc Interv; 2018 Oct; 11(10):e007331. PubMed ID: 30354631
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Midterm clinical outcomes with everolimus-eluting bioresorbable scaffolds versus everolimus-eluting metallic stents for percutaneous coronary interventions: a meta-analysis of randomised trials.
    Cassese S; Byrne RA; Jüni P; Wykrzykowska JJ; Puricel S; Ndrepepa G; Schunkert H; Fusaro M; Cook S; Kimura T; Henriques JPS; Serruys PW; Windecker S; Kastrati A
    EuroIntervention; 2018 Jan; 13(13):1565-1573. PubMed ID: 28671552
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.
    Alfonso F; Pérez-Vizcayno MJ; Cuesta J; García Del Blanco B; García-Touchard A; López-Mínguez JR; Masotti M; Zueco J; Cequier A; Velázquez M; Moreno R; Mainar V; Domínguez A; Moris C; Molina E; Rivero F; Jiménez-Quevedo P; Gonzalo N; Fernández-Pérez C;
    JACC Cardiovasc Interv; 2018 May; 11(10):981-991. PubMed ID: 29798776
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A clinical and angiographic study of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with multivessel coronary artery disease: the EXECUTIVE trial (EXecutive RCT: evaluating XIENCE V in a multi vessel disease).
    Ribichini F; Romano M; Rosiello R; La Vecchia L; Cabianca E; Caramanno G; Milazzo D; Loschiavo P; Rigattieri S; Musarò S; Pironi B; Fiscella A; Amico F; Indolfi C; Spaccarotella C; Bartorelli A; Trabattoni D; Della Rovere F; Rolandi A; Beqaraj F; Belli R; Sangiorgio P; Villani R; Berni A; Sheiban I; Lopera Quijada MJ; Cappi B; Ribaldi L; Vassanelli C;
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1012-22. PubMed ID: 24055444
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial.
    Sotomi Y; Onuma Y; Dijkstra J; Miyazaki Y; Kozuma K; Tanabe K; Popma JJ; de Winter RJ; Serruys PW; Kimura T
    Eur Heart J Cardiovasc Imaging; 2018 Jan; 19(1):59-66. PubMed ID: 28158421
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year follow-up of a propensity score matching comparison (the BIORESOLVE-ISR Study).
    Moscarella E; Tanaka A; Ielasi A; Cortese B; Coscarelli S; De Angelis MC; Piraino D; Latib A; Grigis G; Bianchi R; Buccheri D; Calabrò P; Tespili M; Silva Orrego P; Colombo A; Varricchio A
    Catheter Cardiovasc Interv; 2018 Oct; 92(4):668-677. PubMed ID: 29356269
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of neointimal coverage between durable-polymer everolimus-eluting stents and bioresorbable-polymer everolimus-eluting stents 1 year after implantation using high-resolution coronary angioscopy.
    Nojima Y; Adachi H; Ihara M; Kurimoto T; Okayama K; Sakata Y; Nanto S
    Catheter Cardiovasc Interv; 2019 Aug; 94(2):204-209. PubMed ID: 30737973
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial.
    Serruys PW; Chevalier B; Dudek D; Cequier A; Carrié D; Iniguez A; Dominici M; van der Schaaf RJ; Haude M; Wasungu L; Veldhof S; Peng L; Staehr P; Grundeken MJ; Ishibashi Y; Garcia-Garcia HM; Onuma Y
    Lancet; 2015 Jan; 385(9962):43-54. PubMed ID: 25230593
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A prospective evaluation of a standardized strategy for the use of a polymeric everolimus-eluting bioresorbable scaffold in ST-segment elevation myocardial infarction: Rationale and design of the BVS STEMI STRATEGY-IT study.
    Ielasi A; Varricchio A; Campo G; Leoncini M; Cortese B; Vicinelli P; Brugaletta S; di Uccio FS; Latib A; Tespili M
    Catheter Cardiovasc Interv; 2017 Jun; 89(7):1129-1138. PubMed ID: 27774758
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.
    Alfonso F; Pérez-Vizcayno MJ; García Del Blanco B; García-Touchard A; López-Mínguez JR; Masotti M; Zueco J; Melgares R; Mainar V; Moreno R; Domínguez A; Sanchís J; Bethencourt A; Moreu J; Cequier A; Martí V; Otaegui I; Bastante T; Gonzalo N; Jiménez-Quevedo P; Cárdenas A; Fernández C;
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27412868
    [TBL] [Abstract][Full Text] [Related]  