These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
289 related articles for article (PubMed ID: 28935081)
1. Efficacy and Safety of the Absorb Bioresorbable Vascular Scaffold in Females and Males: Results of an Individual Patient-Level Pooled Meta-Analysis of Randomized Controlled Trials. Shreenivas S; Kereiakes DJ; Ellis SG; Gao R; Kimura T; Onuma Y; Piard-Ruster K; Zhang Y; Koo K; Vu MT; Serruys PW; Stone GW JACC Cardiovasc Interv; 2017 Sep; 10(18):1881-1890. PubMed ID: 28935081 [TBL] [Abstract][Full Text] [Related]
2. Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents: A Meta-Analysis of Randomized Trials. Mahmoud AN; Barakat AF; Elgendy AY; Schneibel E; Mentias A; Abuzaid A; Elgendy IY Circ Cardiovasc Interv; 2017 May; 10(5):. PubMed ID: 28468954 [TBL] [Abstract][Full Text] [Related]
3. Efficacy and Safety of the Absorb Everolimus-Eluting Bioresorbable Scaffold for Treatment of Patients With Diabetes Mellitus: Results of the Absorb Diabetic Substudy. Kereiakes DJ; Ellis SG; Kimura T; Abizaid A; Zhao W; Veldhof S; Vu MT; Zhang Z; Onuma Y; Chevalier B; Serruys PW; Stone GW JACC Cardiovasc Interv; 2017 Jan; 10(1):42-49. PubMed ID: 28017311 [TBL] [Abstract][Full Text] [Related]
4. 1-Year Outcomes of Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Stents: A Propensity-Matched Comparison of the GHOST-EU and XIENCE V USA Registries. Tamburino C; Capranzano P; Gori T; Latib A; Lesiak M; Nef H; Caramanno G; Naber C; Mehilli J; Di Mario C; Sabaté M; Münzel T; Colombo A; Araszkiewicz A; Wiebe J; Geraci S; Jensen C; Mattesini A; Brugaletta S; Capodanno D JACC Cardiovasc Interv; 2016 Mar; 9(5):440-9. PubMed ID: 26875648 [TBL] [Abstract][Full Text] [Related]
5. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial. Suwannasom P; Sotomi Y; Ishibashi Y; Cavalcante R; Albuquerque FN; Macaya C; Ormiston JA; Hill J; Lang IM; Egred M; Fajadet J; Lesiak M; Tijssen JG; Wykrzykowska JJ; de Winter RJ; Chevalier B; Serruys PW; Onuma Y JACC Cardiovasc Interv; 2016 Jun; 9(12):1231-1242. PubMed ID: 27262861 [TBL] [Abstract][Full Text] [Related]
6. Absorb bioresorbable vascular scaffold versus everolimus-eluting metallic stent in ST-segment elevation myocardial infarction: 1-year results of a propensity score matching comparison: the BVS-EXAMINATION Study (bioresorbable vascular scaffold-a clinical evaluation of everolimus eluting coronary stents in the treatment of patients with ST-segment elevation myocardial infarction). Brugaletta S; Gori T; Low AF; Tousek P; Pinar E; Gomez-Lara J; Scalone G; Schulz E; Chan MY; Kocka V; Hurtado J; Gomez-Hospital JA; Münzel T; Lee CH; Cequier A; Valdés M; Widimsky P; Serruys PW; Sabaté M JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt B):189-197. PubMed ID: 25616924 [TBL] [Abstract][Full Text] [Related]
7. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial. Baron SJ; Lei Y; Chinnakondepalli K; Vilain K; Magnuson EA; Kereiakes DJ; Ellis SG; Stone GW; Cohen DJ; JACC Cardiovasc Interv; 2017 Apr; 10(8):774-782. PubMed ID: 28427593 [TBL] [Abstract][Full Text] [Related]
8. Midterm clinical outcomes with everolimus-eluting bioresorbable scaffolds versus everolimus-eluting metallic stents for percutaneous coronary interventions: a meta-analysis of randomised trials. Cassese S; Byrne RA; Jüni P; Wykrzykowska JJ; Puricel S; Ndrepepa G; Schunkert H; Fusaro M; Cook S; Kimura T; Henriques JPS; Serruys PW; Windecker S; Kastrati A EuroIntervention; 2018 Jan; 13(13):1565-1573. PubMed ID: 28671552 [TBL] [Abstract][Full Text] [Related]
9. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials. Muramatsu T; Onuma Y; van Geuns RJ; Chevalier B; Patel TM; Seth A; Diletti R; García-García HM; Dorange CC; Veldhof S; Cheong WF; Ozaki Y; Whitbourn R; Bartorelli A; Stone GW; Abizaid A; Serruys PW; ; ; ; ; ; JACC Cardiovasc Interv; 2014 May; 7(5):482-93. PubMed ID: 24746650 [TBL] [Abstract][Full Text] [Related]
10. Incidence and short-term clinical outcomes of small side branch occlusion after implantation of an everolimus-eluting bioresorbable vascular scaffold: an interim report of 435 patients in the ABSORB-EXTEND single-arm trial in comparison with an everolimus-eluting metallic stent in the SPIRIT first and II trials. Muramatsu T; Onuma Y; García-García HM; Farooq V; Bourantas CV; Morel MA; Li X; Veldhof S; Bartorelli A; Whitbourn R; Abizaid A; Serruys PW; JACC Cardiovasc Interv; 2013 Mar; 6(3):247-57. PubMed ID: 23517836 [TBL] [Abstract][Full Text] [Related]
11. Clinical outcomes at 2 years of the Absorb bioresorbable vascular scaffold versus the Xience drug-eluting metallic stent in patients presenting with acute coronary syndrome versus stable coronary disease-AIDA trial substudy. Tijssen RYG; van der Schaaf RJ; Kraak RP; Vink MA; Hofma SH; Arkenbout EK; Weevers APJD; Kerkmeijer LSM; Onuma Y; Serruys PW; Beijk MAM; Koch KT; Baan J; Vis MM; Piek JJ; Tijssen JGP; Henriques JPS; de Winter RJ; Wykrzykowska JJ Catheter Cardiovasc Interv; 2020 Jan; 95(1):89-96. PubMed ID: 30968559 [TBL] [Abstract][Full Text] [Related]
12. Vasomotor Function Comparative Assessment at 1 and 2 Years Following Implantation of the Absorb Everolimus-Eluting Bioresorbable Vascular Scaffold and the Xience V Everolimus-Eluting Metallic Stent in Porcine Coronary Arteries: Insights From In Vivo Angiography, Ex Vivo Assessment, and Gene Analysis at the Stented/Scaffolded Segments and the Proximal and Distal Edges. Gogas BD; Benham JJ; Hsu S; Sheehy A; Lefer DJ; Goodchild TT; Polhemus DJ; Bouchi YH; Hung OY; Yoo SY; Joshi U; Giddens DP; Veneziani A; Quyyumi A; Rapoza R; King SB; Samady H JACC Cardiovasc Interv; 2016 Apr; 9(7):728-41. PubMed ID: 27056313 [TBL] [Abstract][Full Text] [Related]
13. Absorb bioresorbable vascular scaffold vs. everolimus-eluting metallic stent in small vessel disease: A propensity matched analysis of COMPARE II, RAI, and MAASSTAD-ABSORB studies. Tarantini G; Masiero G; Barioli A; Paradies V; Vlachojannis G; Tellaroli P; Cortese B; di Palma G; Varricchio A; Ielasi A; Loi B; Steffenino G; Ueshima D; Mojoli M; Smits P Catheter Cardiovasc Interv; 2018 Aug; 92(2):E115-E124. PubMed ID: 29513403 [TBL] [Abstract][Full Text] [Related]
14. Overview of the 2016 U.S. Food and Drug Administration Circulatory System Devices Advisory Panel Meeting on the Absorb Bioresorbable Vascular Scaffold System. Steinvil A; Rogers T; Torguson R; Waksman R JACC Cardiovasc Interv; 2016 Sep; 9(17):1757-64. PubMed ID: 27609249 [TBL] [Abstract][Full Text] [Related]
15. Long-Term Outcomes of Absorb Bioresorbable Vascular Scaffold vs. Everolimus-Eluting Metallic Stent - A Randomized Comparison Through 5 Years in Japan. Kozuma K; Tanabe K; Hamazaki Y; Okamura T; Ando J; Ikari Y; Nakagawa Y; Kusano H; Ediebah D; Kimura T; Circ J; 2020 Apr; 84(5):733-741. PubMed ID: 32213737 [TBL] [Abstract][Full Text] [Related]
16. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent. Ishibashi Y; Muramatsu T; Nakatani S; Sotomi Y; Suwannasom P; Grundeken MJ; Cho YK; Garcia-Garcia HM; van Boven AJ; Piek JJ; Sabaté M; Helqvist S; Baumbach A; McClean D; de Sousa Almeida M; Wasungu L; Miquel-Hebert K; Dudek D; Chevalier B; Onuma Y; Serruys PW JACC Cardiovasc Interv; 2015 Jul; 8(8):1053-1063. PubMed ID: 26205444 [TBL] [Abstract][Full Text] [Related]
17. Clinical Outcomes Before and After Complete Everolimus-Eluting Bioresorbable Scaffold Resorption: Five-Year Follow-Up From the ABSORB III Trial. Kereiakes DJ; Ellis SG; Metzger DC; Caputo RP; Rizik DG; Teirstein PS; Litt MR; Kini A; Kabour A; Marx SO; Popma JJ; Tan SH; Ediebah DE; Simonton C; Stone GW; Circulation; 2019 Dec; 140(23):1895-1903. PubMed ID: 31553222 [TBL] [Abstract][Full Text] [Related]
18. Three-Year Outcomes With the Absorb Bioresorbable Scaffold: Individual-Patient-Data Meta-Analysis From the ABSORB Randomized Trials. Ali ZA; Gao R; Kimura T; Onuma Y; Kereiakes DJ; Ellis SG; Chevalier B; Vu MT; Zhang Z; Simonton CA; Serruys PW; Stone GW Circulation; 2018 Jan; 137(5):464-479. PubMed ID: 29089314 [TBL] [Abstract][Full Text] [Related]
19. Risk and timing of clinical events according to diabetic status of patients treated with everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting stent: 2-year results from a propensity score matched comparison of ABSORB EXTEND and SPIRIT trials. Campos CM; Caixeta A; Franken M; Bartorelli AL; Whitbourn RJ; Wu CJ; Li Paul Kao H; Rosli MA; Carrie D; De Bruyne B; Stone GW; Serruys PW; Abizaid A; Catheter Cardiovasc Interv; 2018 Feb; 91(3):387-395. PubMed ID: 28471086 [TBL] [Abstract][Full Text] [Related]
20. Bioresorbable vascular scaffolds for the treatment of coronary artery disease: what have we learned from randomized-controlled clinical trials? Rizik DG; Hermiller JB; Simonton CA; Klassen KJ; Kereiakes DJ Coron Artery Dis; 2017 Jan; 28(1):77-89. PubMed ID: 27561169 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]